Portal hypertension diagnostic study of choice: Difference between revisions
No edit summary |
No edit summary |
||
(One intermediate revision by one other user not shown) | |||
Line 14: | Line 14: | ||
*HVPG reflects the intra-[[sinusoidal]] [[pressure]].<ref name="pmid16496346">{{cite journal |vauthors=Boyer TD |title=Wedged hepatic vein pressure (WHVP): ready for prime time |journal=Hepatology |volume=43 |issue=3 |pages=405–6 |year=2006 |pmid=16496346 |doi=10.1002/hep.21118 |url=}}</ref> | *HVPG reflects the intra-[[sinusoidal]] [[pressure]].<ref name="pmid16496346">{{cite journal |vauthors=Boyer TD |title=Wedged hepatic vein pressure (WHVP): ready for prime time |journal=Hepatology |volume=43 |issue=3 |pages=405–6 |year=2006 |pmid=16496346 |doi=10.1002/hep.21118 |url=}}</ref> | ||
*HVPG is measured through insertion of a [[catheter]] in right [[internal jugular vein]].<ref name="pmid22223943">{{cite journal| author=Chelliah ST, Keshava SN, Moses V, Surendrababu NR, Zachariah UG, Eapen C| title=Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques. | journal=Indian J Radiol Imaging | year= 2011 | volume= 21 | issue= 4 | pages= 291-3 | pmid=22223943 | doi=10.4103/0971-3026.90693 | pmc=3249946 | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=22223943 }}</ref> | *HVPG is measured through insertion of a [[catheter]] in right [[internal jugular vein]].<ref name="pmid22223943">{{cite journal| author=Chelliah ST, Keshava SN, Moses V, Surendrababu NR, Zachariah UG, Eapen C| title=Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques. | journal=Indian J Radiol Imaging | year= 2011 | volume= 21 | issue= 4 | pages= 291-3 | pmid=22223943 | doi=10.4103/0971-3026.90693 | pmc=3249946 | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=22223943 }}</ref> | ||
<br> | |||
<br> | |||
<br> | |||
<br> | |||
<br> | |||
<br> | |||
<br> | |||
==References== | |||
{{Reflist|2}} | |||
{{WH}} | |||
{{WS}} | |||
[[Category:Gastroenterology]] | |||
[[Category:Hepatology]] | |||
[[Category:Disease]] | |||
[[Category:Emergency medicine]] | |||
[[Category:Up-To-Date]] |
Latest revision as of 14:12, 7 December 2017
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Eiman Ghaffarpasand, M.D. [2]
Portal Hypertension Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Portal hypertension diagnostic study of choice On the Web |
American Roentgen Ray Society Images of Portal hypertension diagnostic study of choice |
Risk calculators and risk factors for Portal hypertension diagnostic study of choice |
Overview
Diagnostic study of choice for diagnosing portal hypertension is to measure Hepatic venous pressure gradient (HVPG). HVPG measurement is the difference between hepatic venous wedge pressure (HVWP) and free hepatic venous pressure (FHVP). HVPG reflects the intra-sinusoidal pressure. HVPG is measured through insertion of a catheter in right internal jugular vein.
Other Diagnostic Studies
9cEOpr-MRL4|500}} |
Hepatic venous pressure gradient measurement
- Hepatic venous pressure gradient (HVPG) measurement is the difference between hepatic venous wedge pressure (HVWP) and free hepatic venous pressure (FHVP).
- HVPG reflects the intra-sinusoidal pressure.[1]
- HVPG is measured through insertion of a catheter in right internal jugular vein.[2]
References
- ↑ Boyer TD (2006). "Wedged hepatic vein pressure (WHVP): ready for prime time". Hepatology. 43 (3): 405–6. doi:10.1002/hep.21118. PMID 16496346.
- ↑ Chelliah ST, Keshava SN, Moses V, Surendrababu NR, Zachariah UG, Eapen C (2011). "Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques". Indian J Radiol Imaging. 21 (4): 291–3. doi:10.4103/0971-3026.90693. PMC 3249946. PMID 22223943.