==Overview==
 
'''Intubation''' refers to the placement of a tube into an external or internal orifice of the body. Although the term can refer to [[endoscopy|endoscopic]] procedures, it is most often used to denote '''tracheal intubation'''.  Tracheal intubation is the placement of a flexible plastic tube into the [[vertebrate trachea|trachea]] to protect the patient's airway and provide a means of mechanical ventilation. The most common tracheal intubation is '''orotracheal intubation''' where, with the assistance of a [[laryngoscope]], an [[endotracheal tube]] is passed through the mouth, [[larynx]], and vocal cords, into the trachea. A bulb is then inflated near the distal tip of the tube to help secure it in place and protect the airway from blood, vomit, and secretions. Another possibility is '''nasotracheal intubation''' where a tube is passed through the [[nose]], [[larynx]], [[Vocal folds|vocal cords]], and [[Vertebrate trachea|trachea]].
 
Extubation is the removal of the tube.
 
==Risk vs. benefit==
 
Tracheal intubation is a potentially very dangerous invasive procedure that requires a lot of clinical experience to master.<ref>von Goedecke, A., Herff, H., Paal, P., "Field Airway Management Disasters," ''Anesth Analg,'' 2007;104:481-483.</ref> When performed improperly (e.g., unrecognized esophageal intubation), the associated complications will rapidly lead to the patient's death.<ref>''ACLS: Principles and Practice''. pp. 135-180. Dallas: American Heart Association, 2003. ISBN 0-87493-341-2.</ref> Subsequently, tracheal intubation's role as the "gold standard" of advanced airway maintenance was downplayed (in favor of more basic techniques like bag-valve-mask ventilation) by the American Heart Association's Guidelines for Cardiopulminary Resuscitation in 2000,<ref>''ACLS: Principles and Practice''. pp. 135-180. Dallas: American Heart Association, 2003. ISBN 0-87493-341-2.</ref> and again in 2005.<ref>2005 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. [http://circ.ahajournals.org/cgi/content/full/112/24_suppl/IV-51 Part 7.1: Adjuncts for Airway Control and Ventilation]. ''Circulation'' 2005;'''112''':IV-51-IV-57</ref>
 
==Risk management==
No single method for confirming tube placement has been shown to be 100% reliable. Accordingly, the use of multiple methods to confirm correct tube placement is now the [[standard of care]]. At least one of the methods utilized should be an instrument. Waveform [[capnography]] is emerging as the [[gold standard (test)|gold standard]] instrument for the confirmation of correct tube placement and maintenance of the tube once it is in place.
 
===Predicting ease of intubation===
*Look externally (hx of craniofacial traumas/previous surgery)
*Evaluate 3,3,2 - three of the patient's fingers should be able to fit into his/her mouth when open, three fingers should comfortable fit between the chin and the throat, and two fingers in the thyromental distance (distance from thyroid cartilage to chin)
*Mallampati score (divides airways into four classes according to visible anatomy)
*Obstructions (stridorous breath sounds, wheezing, etc)
*Neck mobility (can patient tilt head back and then forward to touch chest)
 
===Observational methods to confirm correct tube placement===
*Direct visualization of the tube passing through the [[vocal cords]]
*Clear and equal bilateral [[breath sounds]] on auscultation of the chest
*Absent sounds on auscultation of the [[epigastrium]]
*Equal bilateral chest rise with [[Mechanical ventilation|ventilation]]
*Fogging of the tube
*An absence of stomach contents in the tube
 
===Instruments to confirm correct tube placement===
*Colorimetric end tidal CO<sub>2</sub> detector
*Waveform capnography
*Self inflating esophageal bulb
*[[Pulse oximetry]] (patients with a pulse)
 
===Tube maintenance===
The tube is secured in place with tape or an endotracheal tube holder. A cervical collar is sometimes used to prevent motion of the airway. Tube placement should be confirmed after each physical move of the patient and after any unexplained change in the patient's clinical status. Continuous pulse oximetry and continuous waveform capnography are often used to monitor the tube's correct placement.
 
==Indications==
Tracheal intubation is performed by paramedics or physicians in various medical conditions:
* [[Coma]]tose or intoxicated patients who are unable to protect their airways. In such patients, the throat muscles may lose their tone so that the upper airways obstruct or collapse and air can not easily enter into the lungs. Furthermore, protective airway reflexes such as coughing and swallowing, which serve to protect the airways against [[Pulmonary aspiration|aspiration]] of secretions and foreign bodies, may be absent. With tracheal intubation, airway patency is restored and the lower airways can be protected from aspiration.
* [[General anesthesia]]. In anesthetized patients spontaneous respiration may be decreased or absent due to the effect of anesthetics, [[opioid]]s, or [[muscle relaxant]]s. To enable mechanical ventilation, an endotracheal tube is often used, although there are alternative devices such as face masks or [[laryngeal mask airway]]s.
* Diagnostic manipulations of the airways such as [[bronchoscopy]].
* Endoscopic operative procedures to the airways such as [[laser]] therapy or [[stent]]ing of the bronchi.
* Patients who require respiratory support, including [[cardiopulmonary resuscitation]].
 
==Types of tubes==
 
There are various types of tracheal tubes for oral or nasal intubation. Tubes may be flexible or preformed and relatively stiff. They are usually made of flexible plastic or silicone, though they may be armored with metallic rings to prevent kinking. Adult tubes have an inflatable cuff to seal the lower airways against air leakage and gross aspiration. The cuff must be maintained diligently in order to avoid complications from over-inflation, which can include rupture of the trachea, tracheal malacia, tracheoesophageal [[fistula]]. Many of the complications of over-inflated cuffs can be traced to cuff pressure against the tracheal wall causing ischemia of the mucosa underneath. <ref>{{cite journal |author=Sengupta P, Sessler DI, Maglinger P, ''et al'' |title=Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure |journal=BMC Anesthesiol |volume=4 |issue=1 |pages=8 |year=2004 |pmid=15569386 |pmc=535565 |doi=10.1186/1471-2253-4-8 }}</ref>
 
Special double-lumen endotracheal tubes have been developed for ventilating each lung independently -- this is useful during lung and other intra-thoracic surgery. Smaller pediatric tubes generally are uncuffed, as the cricoid cartilage, the narrowest portion of the pediatric airway, often provides an adequate seal for mechanical ventilation. An excessive leak can sometimes be corrected through the placement of a larger (0.5&nbsp;mm larger in internal diameter) endotracheal tube, although in difficult-to-ventilate patients even children may need to use cuffed tubes to allow for high pressure ventilation if the leak is too great to overcome with the ventilator. <ref>{{cite journal |author=Sheridan RL |title=Uncuffed endotracheal tubes should not be used in seriously burned children |journal=Pediatr Crit Care Med |volume=7 |issue=3 |pages=258–9 |year=2006 |month=May |pmid=16575345 |doi=10.1097/01.PCC.0000216681.71594.04 }}</ref><br clear=left>
 
==Techniques==
[[Image:Chapter5figure69b-nasotracheal intubation.jpg|thumb|left|200px|Nasal intubation]]
Several techniques exist. Tracheal intubation can be performed by direct laryngoscopy (conventional technique), in which a [[laryngoscope]] is used to obtain a view of the [[glottis]]. A tube is then inserted under direct vision. This technique can usually only be employed if the patient is comatose (unconscious), under general anesthesia, or has received local or topical anesthesia to the upper airway structures (e.g., using a local anesthetic drug such as lidocaine).
 
[[Rapid sequence induction]] (RSI) is a variation of the standard technique for patients under anesthesia. It is performed when immediate definitive airway management through intubation is required, and especially when there is a risk of [[Pulmonary aspiration|aspiration]]. For RSI, a short acting [[sedative]] such as [[etomidate]], propofol, thiopental or [[midazolam]] is normally administered, followed shortly thereafter by a paralytic such as [[succinylcholine]] or rocuronium. RSI is only correctly performed using an induction agent with a 1 arm-brain circulation time. The only agents classically used are those with 1 arm brain circulation times and are Thiopentone and etomidate. This provides the shortest induction time, and provided the appropriate dose based on body mass is used, protects against awareness during the RSI. Propofol and midazolam (in combination with other induction agents) may be used for induction where there is more time, however, propofol is increasingly being used to good effect for RSI.
 
Another alternative is intubation of the awake patient under [[local anesthesia]] using a flexible [[endoscopy|endoscope]] or by other means (e.g., using a video laryngoscope). This technique is preferred if difficulties are anticipated, as it allows the patient to breathe spontaneously throughout the procedure, thus ensuring ventilation and oxygenation even in the event of a failed intubation.
 
Some alternatives to intubation are
*[[Tracheotomy]] - a surgical technique, typically for patients who require long-term respiratory support
*[[Cricothyrotomy]] - an emergency technique used when intubation is unsuccessful and tracheotomy is not an option.
 
Because the life of a patient can depend on the success of an intubation, it is important to assess possible obstacles beforehand.
The ease of intubation is difficult to predict. One score to assess anatomical difficulties is the [[Mallampati score]],<ref>{{cite journal | author = Mallampati S, Gatt S, Gugino L, Desai S, Waraksa B, Freiberger D, Liu P | title = A clinical sign to predict difficult tracheal intubation: a prospective study. | journal = Can Anaesth Soc J | volume = 32 | issue = 4 | pages = 429-34 | year = 1985 | id = PMID 4027773}}</ref> which is determined by looking at the [[anatomy]] of the [[oral cavity]] and based on the visibility of the base of [[uvula]], [[Fauces (anatomy)|faucial pillar]]s and the [[soft palate]]. It should however be noted that no single score or combination of scores can be trusted to detect all patients who are difficult to intubate. Therefore, persons performing intubation must be familiar with alternative techniques of securing the airways.
 
==History==
The first known description on the surgical procedure of intubation was given in the 1020s by [[Avicenna]] in ''[[The Canon of Medicine]]'' in order to facilitate [[breath]]ing.<ref name=Patricia>Patricia Skinner (2001), [http://findarticles.com/p/articles/mi_g2603/is_0007/ai_2603000716 Unani-tibbi], ''Encyclopedia of Alternative Medicine''</ref> The first detailed report on endotracheal intubation and following artificial respiration of animals was in 1543, when [[Andreas Vesalius]] pointed out in this report that such a measure could sometimes be life-saving. It remained unnoticed however.
 
In 1869, the German surgeon [[Friedrich Trendelenburg]] accomplished the first successful intubation of humans for [[anaesthesia]]. He introduced the tube through a temporary [[tracheotomy]]. In 1878, the British surgeon McEwen performed the first oral intubation.
 
During the First World War, Magill and Macintosh achieved profound improvements in the application of intubation. The most used replaceable spatula of the laryngoscope is named after Macintosh. The Magill curve of an endotracheal tube and the Magill pliers for positioning the tubus during nasal intubation are named after Magill.
 
==Technology==
===Laryngoscope===
Historically, the most common device used for intubation has been the [[laryngoscope]].  Although it has proven sufficient throughout history, many serious problems can arise from its misuse (ex. dental trauma).  Newer technologies have fared better in reducing problematic incidence.
 
There are two styles of laryngoscopes commercially available: Miller, and Macintosh. Miller is a straight blade with a flanged-tip, Macintosh is a curved-blade and small handle. [http://www.stjohnsupplies.co.uk/common/suppliesImage.asp?productId=F74453&mode=thumb]
 
A reduction of the proximal flange of a Miller blade decreases the blade’s effectiveness for laryngeal visualization, whereas a similar modification of a Macintosh blade increases blade-tooth distance, decreases the number of blade-tooth contacts and provides a better laryngeal view.
 
===Fiber optics===
Another common technology used for intubation has been [[fiber optics]].  Although this system provides better visibility, it still has drawback such as inadequate controls and sporadic visibility failure.  It is also considered very slow relative to the laryngoscope.
 
===Image sensor===
The latest technology used to intubate is a computer system utilizing CMOS image sensors.  Visibility failures still occur but to a lesser extent.  Also, this technology is still extremely expensive and little used, but progress has been made to reduce visibility failures and costs.
 
==Pediatric Intubation==
 
Most of the general principles of anaesthesia can be applied to children, but there are some significant anatomical and physiological differences between children and adults that can cause problems, especially in neonates and children weighing less than 15&nbsp;kg.<ref>{{cite book |author=World Health Organization Department of Blood Safety and Clinical Technology |title=Surgical Care at the District Hospital |publisher=World Health Organization |location=Geneva |year=2003 |isbn=92-4-154575-5 }}</ref>
 
===Route for intubation===
 
For infants and young children oral intubation is easier than nasal. Nasal route carries risk of dislodgement of adenoid tissue and epistaxis, but advantages in good fixation of tube. Because of good fixation, Nasal route is preferable then oral route in children undergoing intensive care and requiring prolonged intubation.
 
===Position of tube===
 
The tip of tube should be at midtrachea (between the clavicles on an AP chest X-ray). The position of the tube is checked by auscultation (equal air entry on each side and, in long-term intubation, by chest X-ray).
 
===Type of tubes===
 
'''Uncuffed tubes''' (plain tubes) are commonly used in prepubescent children. In cross section the airway in children is circular which makes plain tracheal tube fits better than cuffed tube.
 
'''Cuffed tubes''' less than 6.0&nbsp;mm and not inflated are accepted for use in paediatry but generally in children less than 10 years old cuffed tubes are avoided to minimize subglottic swelling and ulceration.
 
===Size of tube ===
 
Because the airway of a child is narrow, a small amount of oedema can produce severe obstruction. Oedema can easily be caused by forcing in a tracheal tube that is too tight. (If length of the tube is suspected to be large, immediate changing it to the smaller size is suggestible.) 
 
The correct diameter of the tube is that which results in a small leak at a pressure of about 25&nbsp;cm of water (the tip should be at midtrachea, between the clavicles on an AP chest Xray).
 
For normally nourished children more than about 2 years old, the following formula to calculate the internal diameter of the tube is likely to be of the correct size
 
====Formula====
 
<code><big>Internal diameter of tube (mm) = (age in years ÷ 4) + 4</big></code>
 
====Rough idea====
 
Roughly correct tube size can be indicated by:
 
Inner Diameter: can be estimated by the size of the child's little finger. (For neonates, 3&nbsp;mm internal diameter is accepted while for premature infants 2.5&nbsp;mm internal diameter may be necessary.)
 
Length: can be estimated by doubling the distance from the corner of the child's mouth to the ear canal.
 
*Looking from side of the child’s head while holding the upper end of the tube level with the mouth can provide an idea of how far into the chest the tube will go.
 
==References==
{{reflist|2}}
 
==External links==
* [http://vam.anest.ufl.edu/airwaydevice/index.html Airway devices for intubation]
 
==Relevant journal articles==
*Fridrich P, Frass M, Krenn CG, Weinstabl C, Benumof JL, Krafft P. The UpsherScope in routine and difficult airway management: a randomized, controlled clinical trial. Anesth Analg. 1997 Dec;85(6):1377-81.
*Mallampati SR, Gatt SP, Gugino LD, Desai SP, Waraksa B, Freiberger D, Liu PL. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J. 1985 Jul;32(4):429-34.
*Adnet F, Borron SW, Racine SX, Clemessy JL, Fournier JL, Plaisance P, Lapandry C. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology. 1997 Dec;87(6):1290-7.
*Ovassapian A. Conduct of anesthesia. In: Shields TW, ed. General thoracic surgery. 4th ed.Baltimore:Williams & Wilkins, 1994:307–23.
*de Menezes Lyra R. Glottis simulator. Anesth Analg. 1999 Jun;88(6):1422-3.[http://www.anesthesia-analgesia.org/cgi/reprint/88/6/1424.pdf]
*Smith, N Ty. Simulation in anesthesia: the merits of large simulators versus small simulators. Current Opinion in Anaesthesiology. 13(6):659-665, December 2000.
* {{cite journal |author=Kabrhel C, Thomsen TW, Setnik GS, Walls RM |title=Videos in clinical medicine. Orotracheal intubation |journal=N. Engl. J. Med. |volume=356 |issue=17 |pages=e15 |year=2007 |pmid=17460222 |doi=10.1056/NEJMvcm063574}}
 
{{Emergency medicine}}
{{SIB}}
 
[[Category:Emergency medicine]]
[[Category:Procedure]]
[[Category:Pulmonology]]
[[Category:Intensive care medicine]]
[[Category:Cardiology]]
 
{{Link FA|de}}
[[de:Intubation]]
[[fr:Intubation trachéale]]
[[he:צנרור]]
[[nl:Intubatie]]
[[ja:気管挿管]]
[[no:Intubasjon]]
[[pl:Intubacja]]
[[pt:Intubação endotraqueal]]
[[fi:Intubaatio]]
[[sv:Intubation]]
 
 
{{WH}}
{{WS}}

Latest revision as of 04:34, 17 February 2018

Redirect to: