Glanzmann's thrombasthenia laboratory findings: Difference between revisions
No edit summary |
m (Bot: Removing from Primary care) |
||
Line 31: | Line 31: | ||
[[Category:Disease]] | [[Category:Disease]] | ||
[[Category:Hematology]] | [[Category:Hematology]] | ||
Latest revision as of 21:52, 29 July 2020
Glanzmann's thrombasthenia |
Differentiating Glanzmann's thrombasthenia from other Diseases |
---|
Diagnosis |
Treatment |
Case Studies |
Glanzmann's thrombasthenia laboratory findings On the Web |
American Roentgen Ray Society Images of Glanzmann's thrombasthenia laboratory findings |
Risk calculators and risk factors for Glanzmann's thrombasthenia laboratory findings |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1] Associate Editor(s)-in-Chief: Omer Kamal, M.D.[2]
Overview
Initial evaluation of a patient for a suspected functional platelet disorder should include a complete blood count and examination of the peripheral blood smear. The red blood cell count is usually normal. Some patients with Glanzmann's thrombasthenia may have reduced count of red blood cell, because of coexisting iron deficiency or bleeding. The platelet count in Glanzmann's thrombasthenia is mostly on the lower end of normal. The activated partial thromboplastin time (PTT) and prothrombin time (PT) are in this disease commonly normal. Platelet aggregation assays which is panel of assays measuring platelet aggregation and activation in vitro using like ADP, arachidonic acid, collagen, epinephrine, thrombin, and ristocetin. There are several newer technologies in current clinical use measuring various aspects of platelet function. The most widely tested is the PFA-100 device. It is used to distinguish between an aspirin-induced defect and more severe platelet dysfunction. Platelet aggregation failure in LTA with all agonists except ristocetin is diagnostic of Glanzmann's thrombasthenia. Laboratory findings consistent with the diagnosis of Glanzmann's thrombasthenia include prolonged bleeding time (BT) and failure of platelets plugging to the collagen-based filter in the PFA-100 test.
Laboratory Findings
CBC and peripheral smear examination
Initial evaluation of a patient for a suspected functional platelet disorder should include a complete blood count and examination of the peripheral blood smear. The red blood cell count is usually normal. Some patients with Glanzmann's thrombasthenia may have reduced count of red blood cell, because of coexisting iron deficiency or bleeding. The platelet count in Glanzmann's thrombasthenia is mostly on the lower end of normal.[1][2]
Thromboplastin (PTT) and Prothrombin time (PT)
The activated partial thromboplastin time (PTT) and prothrombin time (PT) are in this disease commonly normal.[3][4]
Platelet aggregation assays
Platelet aggregation assays which is panel of assays measuring platelet aggregation and activation in vitro using like ADP, arachidonic acid, collagen, epinephrine, thrombin, and ristocetin [5][6]
Automated platelet function screening tests
There are several newer technologies in current clinical use measuring various aspects of platelet function [7][8][9][10][11]
Platelet Function Analyzer (PFA-100)
The most widely tested is the PFA-100 device. It is used to distinguish between an aspirin-induced defect and more severe platelet dysfunction [7][8][9][10][11][12][13]. Platelet aggregation failure in LTA with all agonists except ristocetin is diagnostic of Glanzmann's thrombasthenia. Laboratory findings consistent with the diagnosis of Glanzmann's thrombasthenia include prolonged bleeding time (BT) and failure of platelets plugging to the collagen-based filter in the PFA-100 test.
The diagnosis of Glanzmann thrombasthenia is confirmed through monoclonal antibody testing and flow cytometry. The coagulation tests and platelet count are usually normal among patients with Glanzmann's thrombasthenia. The platelet morphology on peripheral blood smear is normal in patients with Glanzmann's thrombasthenia [4] [3]
References
- ↑ Gunay-Aygun M, Zivony-Elboum Y, Gumruk F, Geiger D, Cetin M, Khayat M, Kleta R, Kfir N, Anikster Y, Chezar J, Arcos-Burgos M, Shalata A, Stanescu H, Manaster J, Arat M, Edwards H, Freiberg AS, Hart PS, Riney LC, Patzel K, Tanpaiboon P, Markello T, Huizing M, Maric I, Horne M, Kehrel BE, Jurk K, Hansen NF, Cherukuri PF, Jones M, Cruz P, Mullikin JC, Nurden A, White JG, Gahl WA, Falik-Zaccai T (December 2010). "Gray platelet syndrome: natural history of a large patient cohort and locus assignment to chromosome 3p". Blood. 116 (23): 4990–5001. doi:10.1182/blood-2010-05-286534. PMC 3012593. PMID 20709904.
- ↑ Drouin A, Favier R, Massé JM, Debili N, Schmitt A, Elbim C, Guichard J, Adam M, Gougerot-Pocidalo MA, Cramer EM (September 2001). "Newly recognized cellular abnormalities in the gray platelet syndrome". Blood. 98 (5): 1382–91. PMID 11520786.
- ↑ 3.0 3.1 Nurden AT (April 2006). "Glanzmann thrombasthenia". Orphanet J Rare Dis. 1: 10. doi:10.1186/1750-1172-1-10. PMC 1475837. PMID 16722529.
- ↑ 4.0 4.1 Solh T, Botsford A, Solh M (2015). "Glanzmann's thrombasthenia: pathogenesis, diagnosis, and current and emerging treatment options". J Blood Med. 6: 219–27. doi:10.2147/JBM.S71319. PMC 4501245. PMID 26185478.
- ↑ Quiroga T, Goycoolea M, Matus V, Zúñiga P, Martínez C, Garrido M, Aranda E, Leighton F, Panes O, Pereira J, Mezzano D (December 2009). "Diagnosis of mild platelet function disorders. Reliability and usefulness of light transmission platelet aggregation and serotonin secretion assays". Br. J. Haematol. 147 (5): 729–36. doi:10.1111/j.1365-2141.2009.07890.x. PMID 19775303.
- ↑ Jennings I, Woods TA, Kitchen S, Walker ID (August 2008). "Platelet function testing: practice among UK National External Quality Assessment Scheme for Blood Coagulation participants, 2006". J. Clin. Pathol. 61 (8): 950–4. doi:10.1136/jcp.2008.057174. PMID 18663056.
- ↑ 7.0 7.1 Cattaneo M, Lecchi A, Agati B, Lombardi R, Zighetti ML (November 1999). "Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion". Thromb. Res. 96 (3): 213–7. PMID 10588464.
- ↑ 8.0 8.1 Mammen EF, Comp PC, Gosselin R, Greenberg C, Hoots WK, Kessler CM, Larkin EC, Liles D, Nugent DJ (1998). "PFA-100 system: a new method for assessment of platelet dysfunction". Semin. Thromb. Hemost. 24 (2): 195–202. doi:10.1055/s-2007-995840. PMID 9579642.
- ↑ 9.0 9.1 Jilma B (September 2001). "Platelet function analyzer (PFA-100): a tool to quantify congenital or acquired platelet dysfunction". J. Lab. Clin. Med. 138 (3): 152–63. doi:10.1067/mlc.2001.117406. PMID 11528368.
- ↑ 10.0 10.1 Favaloro EJ (March 2001). "Utility of the PFA-100 for assessing bleeding disorders and monitoring therapy: a review of analytical variables, benefits and limitations". Haemophilia. 7 (2): 170–9. PMID 11260277.
- ↑ 11.0 11.1 Harrison P (December 2000). "Progress in the assessment of platelet function". Br. J. Haematol. 111 (3): 733–44. PMID 11122132.
- ↑ Hayward CP, Pai M, Liu Y, Moffat KA, Seecharan J, Webert KE, Cook RJ, Heddle NM (April 2009). "Diagnostic utility of light transmission platelet aggregometry: results from a prospective study of individuals referred for bleeding disorder assessments". J. Thromb. Haemost. 7 (4): 676–84. doi:10.1111/j.1538-7836.2009.03273.x. PMID 19143930.
- ↑ BORN GV (June 1962). "Aggregation of blood platelets by adenosine diphosphate and its reversal". Nature. 194: 927–9. PMID 13871375.