Spectroscopy: Difference between revisions

Jump to navigation Jump to search
Mdoherty (talk | contribs)
No edit summary
 
WikiBot (talk | contribs)
m Robot: Automated text replacement (-{{SIB}} +, -{{EH}} +, -{{EJ}} +, -{{Editor Help}} +, -{{Editor Join}} +)
 
(One intermediate revision by one other user not shown)
Line 3: Line 3:
{{CMG}}
{{CMG}}


{{EH}}
 


==Overview==
==Overview==
Line 151: Line 151:
{{Analytical chemistry}}
{{Analytical chemistry}}
{{BranchesofSpectroscopy}}
{{BranchesofSpectroscopy}}
{{SIB}}
 


[[Category:Spectroscopy| ]]
[[Category:Spectroscopy| ]]
Line 198: Line 198:
{{WikiDoc Help Menu}}
{{WikiDoc Help Menu}}
{{WikiDoc Sources}}
{{WikiDoc Sources}}
{{jb1}}

Latest revision as of 16:11, 20 August 2012

Animation of the dispersion of light as it travels through a triangular prism.

WikiDoc Resources for Spectroscopy

Articles

Most recent articles on Spectroscopy

Most cited articles on Spectroscopy

Review articles on Spectroscopy

Articles on Spectroscopy in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Spectroscopy

Images of Spectroscopy

Photos of Spectroscopy

Podcasts & MP3s on Spectroscopy

Videos on Spectroscopy

Evidence Based Medicine

Cochrane Collaboration on Spectroscopy

Bandolier on Spectroscopy

TRIP on Spectroscopy

Clinical Trials

Ongoing Trials on Spectroscopy at Clinical Trials.gov

Trial results on Spectroscopy

Clinical Trials on Spectroscopy at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Spectroscopy

NICE Guidance on Spectroscopy

NHS PRODIGY Guidance

FDA on Spectroscopy

CDC on Spectroscopy

Books

Books on Spectroscopy

News

Spectroscopy in the news

Be alerted to news on Spectroscopy

News trends on Spectroscopy

Commentary

Blogs on Spectroscopy

Definitions

Definitions of Spectroscopy

Patient Resources / Community

Patient resources on Spectroscopy

Discussion groups on Spectroscopy

Patient Handouts on Spectroscopy

Directions to Hospitals Treating Spectroscopy

Risk calculators and risk factors for Spectroscopy

Healthcare Provider Resources

Symptoms of Spectroscopy

Causes & Risk Factors for Spectroscopy

Diagnostic studies for Spectroscopy

Treatment of Spectroscopy

Continuing Medical Education (CME)

CME Programs on Spectroscopy

International

Spectroscopy en Espanol

Spectroscopy en Francais

Business

Spectroscopy in the Marketplace

Patents on Spectroscopy

Experimental / Informatics

List of terms related to Spectroscopy

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]


Overview

Spectroscopy was originally the study of the interaction between radiation and matter as a function of wavelength λ. In fact, historically, spectroscopy referred to the use of visible light dispersed according to its wavelength, e.g. by a prism. Later the concept was expanded greatly to comprise any measurement of a quantity as function of either wavelength or frequency. Thus it also can refer to interactions with particle radiation or to a response to an alternating field or varying frequency ν. An further extension of the scope of the definition added energy E as a variable, once the very close relationship E=hν for photons was realized. A plot of the response as a function of wavelength — or more commonly frequency — is referred to as a spectrum.

Spectrometry is the measurement of these responses and an instrument which performs such measurements is a spectrometer or spectrograph, although these terms are more limited in use to the orginal field of optics from which the concept sprang.

Spectroscopy is often used in physical and analytical chemistry for the identification of substances through the spectrum emitted from or absorbed by them. Spectroscopy is also heavily used in astronomy and remote sensing. Most large telescopes have spectrometers, which are used either to measure the chemical composition and physical properties of astronomical objects or to measure their velocities from the Doppler shift of their spectral lines.

Classification of methods

Nature of excitation measured

The type of spectroscopy depends on the physical quantity measured. Normally, the quantity that is measured is an intensity, either of energy absorbed or produced.

  • Optical Spectroscopy (Electromagnetic Spectroscopy) involves interactions of matter with electromagnetic radiation or light. Ultraviolet-visible spectroscopy is an example.
  • Electron Spectroscopy involves interactions with electron beams. Auger spectroscopy involves inducing the Auger effect with an electron beam. In this case the measurement typically involves the kinetic energy of the electron as variable.
  • Mass spectroscopy involves the interaction of charged species with magnetic and/or electric fields, giving rise to a mass spectrum. The term "mass spectroscopy" is deprecated in favor of mass spectrometry, for the technique is primarily a form of measurement, though it does produce a spectrum for observation. This spectrum has the mass m as variable, but the measurement is essentially one of the kinetic energy of the particle.
  • Acoustic spectroscopy involves the frequency of sound.
  • Dielectric spectroscopy involves the frequency of an external electrical field
  • Mechanical spectroscopy involves the frequency of an external mechanical stress, e.g. a torsion applied to a piece of material.

Measurement process

Most spectroscopic methods are differentiated as either atomic or molecular based on whether or not they apply to atoms or molecules. Along with that distinction, they can be classified on the nature of their interaction:

Common types

Spectrum of light from a fluorescent lamp showing prominent mercury peaks.

Fluorescence

Fluorescence spectroscopy uses higher energy photons to excite a sample, which will then emit lower energy photons. This technique has become popular for its biochemical and medical applications, and can be used for confocal microscopy, fluorescence resonance energy transfer, and fluorescence lifetime imaging.

X-ray

When X-rays of sufficient frequency (energy) interact with a substance, inner shell electrons in the atom are excited to outer empty orbitals, or they may be removed completely, ionizing the atom. The inner shell "hole" will then be filled by electrons from outer orbitals. The energy available in this de-excitation process is emitted as radiation (fluorescence) or will remove other less-bound electrons from the atom (Auger effect). The absorption or emission frequencies (energies) are characteristic of the specific atom. In addition, for a specific atom small frequency (energy) variations occur which are characteristic of the chemical bonding. With a suitable apparatus, these characteristic X-ray frequencies or Auger electron energies can be measured. X-ray absorption and emission spectroscopy is used in chemistry and material sciences to determine elemental composition and chemical bonding.

X-ray crystallography is a scattering process; crystalline materials scatter X-rays at well-defined angles. If the wavelength of the incident X-rays is known, this allows calculation of the distances between planes of atoms within the crystal. The intensities of the scattered X-rays give information about the atomic positions and allow the arrangement of the atoms within the crystal structure to be calculated.

Flame

Liquid solution samples are aspirated into a burner or nebulizer/burner combination, desolvated, atomized, and sometimes excited to a higher energy electronic state. The use of a flame during analysis requires fuel and oxidant, typically in the form of gases. Common fuel gases used are acetylene (ethyne) or hydrogen. Common oxidant gases used are oxygen, air, or nitrous oxide. These methods are often capable of analyzing metallic element analytes in the part per million, billion, or possibly lower concentration ranges. Light detectors are needed to detect light with the analysis information coming from the flame.

  • Atomic Emission Spectroscopy - This method uses flame excitation; atoms are excited from the heat of the flame to emit light. This method commonly uses a total consumption burner with a round burning outlet. A higher temperature flame than atomic absorption spectroscopy (AA) is typically used to produce excitation of analyte atoms. Since analyte atoms are excited by the heat of the flame, no special elemental lamps to shine into the flame are needed. A high resolution polychromator can be used to produce an emission intensity vs. wavelength spectrum over a range of wavelengths showing multiple element excitation lines, meaning multiple elements can be detected in one run. Alternatively, a monochromator can be set at one wavelength to concentrate on analysis of a single element at a certain emission line. Plasma emission spectroscopy is a more modern version of this method. See Flame emission spectroscopy for more details.
  • Atomic absorption spectroscopy (often called AA) - This method commonly uses a pre-burner nebulizer (or nebulizing chamber) to create a sample mist and a slot-shaped burner which gives a longer pathlength flame. The temperature of the flame is low enough that the flame itself does not excite sample atoms from their ground state. The nebulizer and flame are used to desolvate and atomize the sample, but the excitation of the analyte atoms is done by the use of lamps shining through the flame at various wavelengths for each type of analyte. In AA, the amount of light absorbed after going through the flame determines the amount of analyte in the sample. A graphite furnace for heating the sample to desolvate and atomize is commonly used for greater sensitivity. The graphite furnace method can also analyze some solid or slurry samples. Because of its good sensitivity and selectivity, it is still a commonly used method of analysis for certain trace elements in aqueous (and other liquid) samples.
  • Atomic Fluorescence Spectroscopy - This method commonly uses a burner with a round burning outlet. The flame is used to solvate and atomize the sample, but a lamp shines light at a specific wavelength into the flame to excite the analyte atoms in the flame. The atoms of certain elements can then fluoresce emitting light in a different direction. The intensity of this fluorescing light is used for quantifying the amount of analyte element in the sample. A graphite furnace can also be used for atomic fluorescence spectroscopy. This method is not as commonly used as atomic absorption or plasma emission spectroscopy.

Plasma Emission Spectroscopy In some ways similar to flame atomic emission spectroscopy, it has largely replaced it.

  • Direct-current plasma (DCP)

A direct-current plasma (DCP) is created by an electrical discharge between two electrodes. A plasma support gas is necessary, and Ar is common. Samples can be deposited on one of the electrodes, or if conducting can make up one electrode.

  • Glow discharge-optical emission spectrometry (GD-OES)
  • Microwave-induced plasma (MIP)

Spark or arc (emission) spectroscopy - is used for the analysis of metallic elements in solid samples. For non-conductive materials, a sample is ground with graphite powder to make it conductive. In traditional arc spectroscopy methods, a sample of the solid was commonly ground up and destroyed during analysis. An electric arc or spark is passed through the sample, heating the sample to a high temperature to excite the atoms in it. The excited analyte atoms glow emitting light at various wavelengths which could be detected by common spectroscopic methods. Since the conditions producing the arc emission typically are not controlled quantitatively, the analysis for the elements is qualitative. Nowadays, the spark sources with controlled discharges under an argon atmosphere allow that this method can be considered eminently quantitative, and its use is widely expanded worldwide through production control laboratories of foundries and steel mills.

Visible

Many atoms emit or absorb visible light. In order to obtain a fine line spectrum, the atoms must be in a gas phase. This means that the substance has to be vaporised. The spectrum is studied in absorption or emission. Visible absorption spectroscopy is often combined with UV absorption spectroscopy in UV/Vis spectroscopy.

Ultraviolet

All atoms absorb in the Ultraviolet (UV) region because these photons are energetic enough to excite outer electrons. If the frequency is high enough, photoionisation takes place. UV spectroscopy is also used in quantifying protein and DNA concentration as well as the ratio of protein to DNA concentration in a solution. Several amino acids usually found in protein, such as tryptophan, absorb light in the 280nm range and DNA absorbs light in the 260nm range. For this reason, the ratio of 260/280nm absorbance is a good general indicator of the relative purity of a solution in terms of these two macromolecules. Reasonable estimates of protein or DNA concentration can also be made this way using Beer's law.

Infrared

Infrared spectroscopy offers the possibility to measure different types of inter atomic bond vibrations at different frequencies. Especially in organic chemistry the analysis of IR absorption spectra shows what type of bonds are present in the sample.

Raman

Raman spectroscopy uses the inelastic scattering of light to analyse vibrational and rotational modes of molecules. The resulting 'fingerprints' are an aid to analysis.

Nuclear magnetic resonance

Nuclear magnetic resonance spectroscopy analyzes the magnetic properties of certain atomic nuclei to determine different electronic local environments of hydrogen, carbon, or other atoms in an organic compound or other compound. This is used to help determine the structure of the compound.

Photoemission

Mössbauer

Transmission or conversion-electron (CEMS) modes of Mössbauer spectroscopy probe the properties of specific isotope nuclei in different atomic environments by analyzing the resonant absorption of characteristic energy gamma-rays known as the Mössbauer effect.

Other types

Background subtraction

Background subtraction is a term typically used in spectroscopy when one explains the process of acquiring a background radiation level (or ambient radiation level) and then makes an algorithmic adjustment to the data to obtain qualitative information about any deviations from the background, even when they are an order of magnitude less decipherable than the background itself.

Background subtraction can effect a number of statistical calculations (Continuum, Compton, Bremsstrahlung) leading to improved overall system performance.

See also

External links

Template:Organic chemistry Template:Analytical chemistry Template:BranchesofSpectroscopy


ar:مطيافيات bg:Спектроскопия ca:Espectroscòpia cs:Spektroskopie da:Spektroskopi de:Spektroskopie et:Spektroskoopia el:Φασματοσκοπία fa:طیف‌نمایی gl:Espectroscopia hr:Spektroskopija id:Spektroskopi it:Spettroscopia he:ספקטרוסקופיה hu:Színképelemzés ms:Spektroskopi nl:Spectroscopie no:Spektroskopi nn:Spektroskopi simple:Spectroscopy sl:Spektroskopija sr:Спектроскопија su:Spéktroskopi fi:Spektroskopia sv:Spektroskopi uk:Спектроскопія


Template:WikiDoc Sources Template:Jb1