Atrial septal defect video showing percutaneous repair: Difference between revisions
New page: {{Atrial septal defect}} {{CMG}}; '''Associate Editor(s)-In-Chief:''' Priyamvada Singh, M.B.B.S. [mailto:psingh@perfuse.org]; {{CZ}} '''Assistant Editor(s)-In-Chief:''... |
m Robot: Automated text replacement (-msbeih@perfuse.org +msbeih@wikidoc.org, -psingh@perfuse.org +psingh13579@gmail.com, -agovi@perfuse.org +agovi@wikidoc.org, -rgudetti@perfuse.org +ravitheja.g@gmail.com, -lbiller@perfuse.org +lbiller@wikidoc.org,... |
||
(10 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | |||
{{Atrial septal defect}} | {{Atrial septal defect}} | ||
{{CMG}}; '''Associate Editor(s)-In-Chief:''' [[Priyamvada Singh|Priyamvada Singh, M.B.B.S.]] [mailto: | {{CMG}}; '''Associate Editor(s)-In-Chief:''' [[Priyamvada Singh|Priyamvada Singh, M.B.B.S.]] [mailto:psingh13579@gmail.com]; {{CZ}} '''Assistant Editor(s)-In-Chief:''' [[Kristin Feeney|Kristin Feeney, B.S.]] [mailto:kfeeney@elon.edu] | ||
==Overview== | ==Overview== | ||
'''Percutaneous device closure''' of [[atrial septal defect]], is currently approved only for [[Ostium secundum atrial septal defect|secundum defects]]. Prior to the procedure, the patient is started on [[antiplatelet]] therapy for 6 months to prevent [[thrombus]] formation. [[Transesophageal echocardiography]] along with stop-flow technique is used for determining the device size, position, and deployment. | |||
<youtube | ==Pre-surgical considerations== | ||
'''1)''' Prior to undergoing [[Atrial septal defect percutaneous|percutaneous closure]], eligible [[atrial septal defect]] patients must undergo pharmacologic preparation therapy. | |||
'''2)''' Most therapy regimens include [[Antiplatelet Therapy to Support PCI (patient information)|antiplatelet drugs]] such as [[aspirin]] or [[clopidogrel]] for a minimum of six months to protect patients against [[thrombus]] formation. | |||
'''3)''' [[Ostium secundum atrial septal defect|Secundum defects]] are assessed via [[Atrial septal defect echocardiography|echocardiographic monitoring]] to determine the anatomic viability of percutaneous closure. | |||
'''4)''' The ideal [[Ostium secundum atrial septal defect|secundum defect]] is less than '''30mm in diameter''' with an accompanying '''rim''' of tissue around the defect of at least '''5mm'''. | |||
'''5)''' The rim of tissue serves to prevent impingement upon the [[superior vena cava|superior vena cava (SVC)]], [[inferior vena cava|inferior vena cava (IVC)]], as well as the [[tricuspid valve|tricuspid]] or [[mitral valve|mitral]] valves.<ref name="pmid1389707">{{cite journal| author=Ferreira SM, Ho SY, Anderson RH| title=Morphological study of defects of the atrial septum within the oval fossa: implications for transcatheter closure of left-to-right shunt. | journal=Br Heart J | year= 1992 | volume= 67 | issue= 4 | pages= 316-20 | pmid=1389707 | doi= | pmc=PMC1024841 | url= }} </ref> | |||
==Steps during per-cutaneous closure== | |||
The salient feature of the [[Atrial septal defect percutaneous closure | percutaneous closure]] are- | |||
'''1)''' Device is placed via [[femoral vein]] | |||
'''2)''' Best results are for centrally located [[Ostium secundum atrial septal defect|secundum defects]]. | |||
'''3)''' Static diameter of the defect is assessed by using [[transesophageal echocardiography]] | |||
'''4)''' [[Transesophageal echocardiography]] used for determining the device size, position, and deployment | |||
'''5)''' A ''' 'stop-flow' ''' technique is used to select the proper diameter of the device | |||
'''6)''' In the stop flow technique, the sizing balloon is inflated until no flow is visible through the defect using [[transesophageal echocardiography]]. | |||
'''7)''' The margins of the defect must be '''≤5 mm''' to accommodate the edges of the device. | |||
{{#ev:youtube|Gros-u7YCTk}} | |||
==References== | ==References== | ||
{{reflist|2}} | {{reflist|2}} | ||
{{WH}} | {{WH}} | ||
{{WS}} | {{WS}} |
Latest revision as of 00:54, 2 November 2012
Atrial Septal Defect Microchapters | |
Treatment | |
---|---|
Surgery | |
| |
Special Scenarios | |
Case Studies | |
Atrial septal defect video showing percutaneous repair On the Web | |
American Roentgen Ray Society Images of Atrial septal defect video showing percutaneous repair | |
FDA on Atrial septal defect video showing percutaneous repair | |
CDC on Atrial septal defect video showing percutaneous repair | |
Atrial septal defect video showing percutaneous repair in the news | |
Blogs on Atrial septal defect video showing percutaneous repair | |
Risk calculators and risk factors for Atrial septal defect video showing percutaneous repair | |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-In-Chief: Priyamvada Singh, M.B.B.S. [2]; Cafer Zorkun, M.D., Ph.D. [3] Assistant Editor(s)-In-Chief: Kristin Feeney, B.S. [4]
Overview
Percutaneous device closure of atrial septal defect, is currently approved only for secundum defects. Prior to the procedure, the patient is started on antiplatelet therapy for 6 months to prevent thrombus formation. Transesophageal echocardiography along with stop-flow technique is used for determining the device size, position, and deployment.
Pre-surgical considerations
1) Prior to undergoing percutaneous closure, eligible atrial septal defect patients must undergo pharmacologic preparation therapy.
2) Most therapy regimens include antiplatelet drugs such as aspirin or clopidogrel for a minimum of six months to protect patients against thrombus formation.
3) Secundum defects are assessed via echocardiographic monitoring to determine the anatomic viability of percutaneous closure.
4) The ideal secundum defect is less than 30mm in diameter with an accompanying rim of tissue around the defect of at least 5mm.
5) The rim of tissue serves to prevent impingement upon the superior vena cava (SVC), inferior vena cava (IVC), as well as the tricuspid or mitral valves.[1]
Steps during per-cutaneous closure
The salient feature of the percutaneous closure are-
1) Device is placed via femoral vein
2) Best results are for centrally located secundum defects.
3) Static diameter of the defect is assessed by using transesophageal echocardiography
4) Transesophageal echocardiography used for determining the device size, position, and deployment
5) A 'stop-flow' technique is used to select the proper diameter of the device
6) In the stop flow technique, the sizing balloon is inflated until no flow is visible through the defect using transesophageal echocardiography.
7) The margins of the defect must be ≤5 mm to accommodate the edges of the device.
{{#ev:youtube|Gros-u7YCTk}}