Legionella: Difference between revisions
Gerald Chi- (talk | contribs) mNo edit summary |
No edit summary |
||
(8 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Taxobox | {{Taxobox | ||
| color = lightgrey | | color = lightgrey | ||
Line 13: | Line 12: | ||
| genus = '''''Legionella''''' | | genus = '''''Legionella''''' | ||
| genus_authority = Brenner ''et al.'' 1979 | | genus_authority = Brenner ''et al.'' 1979 | ||
}} | }} | ||
{{ | __NOTOC__ | ||
{{Legionellosis}} | |||
{{About0|Legionellosis}} | |||
{{Seealso|Legionella pneumophila}} | |||
{{CMG}} | {{CMG}} | ||
Line 79: | Line 27: | ||
<ref>{{cite web|author=Lawrence K. Altman |title=In Philadelphia 30 Years Ago, an Eruption of Illness and Fear|date=09-01-2006|publisher=New York Times|url=http://www.nytimes.com/2006/08/01/health/01docs.html?_r=1&oref=slogin&pagewanted=print}}</ref>. | <ref>{{cite web|author=Lawrence K. Altman |title=In Philadelphia 30 Years Ago, an Eruption of Illness and Fear|date=09-01-2006|publisher=New York Times|url=http://www.nytimes.com/2006/08/01/health/01docs.html?_r=1&oref=slogin&pagewanted=print}}</ref>. | ||
On January 18, 1977 the causative agent was identified as a previously unknown bacterium, subsequently named Legionella. See [[Legionnaire's Disease]] for full details. | On January 18, 1977 the causative agent was identified as a previously unknown bacterium, subsequently named Legionella. See [[Legionnaire's Disease]] for full details. | ||
==Historical Perspective== | |||
In 1976, ''legionella'' was discovered after an outbreak among people who attended the Philadelphia convention of the American Legion. Those affected had a type of pneumonia that eventually became known as Legionnaires’ disease. | |||
==Classification== | |||
The genus ''Legionella'' is made up of 58 species and 3 subspecies (pneumophila, fraseri, and pascullei ). | |||
''Legionella'' is a ''Gram-negative bacteria'' with strict growth requirements. | |||
Monoclonal antibodies against lipopolysaccharide epitopes on the bacterial cell surface detect L pneumophila serogroup 1. | |||
==Pathophysiology== | |||
''Legionella'' reside in drinking and surface water and are transmitted in aerosols to humans. It multiplies intracellularly in alveolar macrophages leading to an immune reaction that produces destructive alveolar inflammation. Inoculation of surgical wounds via contaminated tap water has been recorded. | |||
==Causes== | |||
legionnaires disease is caused by a bacterium known as ''legionella'' found naturally in freshwater environments, like lakes and streams. | |||
''Legionella'' can become a health concern when it grows and spreads in human-made water systems example | |||
*Decorative fountains and water features | |||
*Showerheads and sink faucets | |||
*Hot water tanks and heaters | |||
*Cooling towers | |||
*Large, complex plumbing systems | |||
==Detection== | ==Detection== | ||
Line 143: | Line 111: | ||
Many governmental agencies, cooling tower manufacturers and industrial trade organizations have developed design and maintenance guidelines for preventing or controlling the growth of ''Legionella'' in cooling towers. Below is a list of sources for such guidelines: | Many governmental agencies, cooling tower manufacturers and industrial trade organizations have developed design and maintenance guidelines for preventing or controlling the growth of ''Legionella'' in cooling towers. Below is a list of sources for such guidelines: | ||
*[http://www.legionella.org | *[http://www.legionella.org] | ||
*[http://www.legionellae.org/guidelines/guidelines.htm] Legionella control in Ornamental Fountains | *[http://www.legionellae.org/guidelines/guidelines.htm] Legionella control in Ornamental Fountains | ||
*[http://www.ashrae.org/publications/detail/14891#Gdl12] ASHRAE Guideline | *[http://www.ashrae.org/publications/detail/14891#Gdl12] ASHRAE Guideline | ||
Line 182: | Line 150: | ||
* [http://www.ashrae.org/publications/detail/14891#Gdl12/ ASHRAE Guideline] | * [http://www.ashrae.org/publications/detail/14891#Gdl12/ ASHRAE Guideline] | ||
* [http://www.nucleagena.pl/legionella.htm NUCLEAGENA: Polish company for the detection of Legionella] | * [http://www.nucleagena.pl/legionella.htm NUCLEAGENA: Polish company for the detection of Legionella] | ||
[[Category:Proteobacteria]] | [[Category:Proteobacteria]] | ||
[[Category:Bacterial diseases]] | [[Category:Bacterial diseases]] | ||
[[Category:Industrial hygiene]] | [[Category:Industrial hygiene]] | ||
Latest revision as of 13:28, 31 March 2022
Legionella | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Legionella sp. under UV illumination.
| ||||||||||||
Scientific classification | ||||||||||||
|
Legionellosis Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Legionella On the Web |
American Roentgen Ray Society Images of Legionella |
Template:Seealso Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Overview
Legionella is a Gram negative bacterium, including species that cause legionellosis or Legionnaires' disease, most notably L. pneumophila.[1][2]
Legionella are common in many environments, with at least 50 species and 70 serogroups identified. The side-chains of the cell wall carry the bases responsible for the somatic antigen specificity of these organisms. The chemical composition of these side chains both with respect to components as well as arrangement of the different sugars determines the nature of the somatic or O antigen determinants, which are essential means of serologically classifying many Gram-negative bacteria.
Legionella acquired its name after a July, 1976 outbreak among people attending a convention of the American Legion in Philadelphia. The mystery disease sickened 221 persons, causing 34 deaths. In that bicentennial year, a pandemic among U.S. war veterans was widely publicized and produced a national panic [3]. On January 18, 1977 the causative agent was identified as a previously unknown bacterium, subsequently named Legionella. See Legionnaire's Disease for full details.
Historical Perspective
In 1976, legionella was discovered after an outbreak among people who attended the Philadelphia convention of the American Legion. Those affected had a type of pneumonia that eventually became known as Legionnaires’ disease.
Classification
The genus Legionella is made up of 58 species and 3 subspecies (pneumophila, fraseri, and pascullei ). Legionella is a Gram-negative bacteria with strict growth requirements. Monoclonal antibodies against lipopolysaccharide epitopes on the bacterial cell surface detect L pneumophila serogroup 1.
Pathophysiology
Legionella reside in drinking and surface water and are transmitted in aerosols to humans. It multiplies intracellularly in alveolar macrophages leading to an immune reaction that produces destructive alveolar inflammation. Inoculation of surgical wounds via contaminated tap water has been recorded.
Causes
legionnaires disease is caused by a bacterium known as legionella found naturally in freshwater environments, like lakes and streams.
Legionella can become a health concern when it grows and spreads in human-made water systems example
- Decorative fountains and water features
- Showerheads and sink faucets
- Hot water tanks and heaters
- Cooling towers
- Large, complex plumbing systems
Detection
Legionella is traditionally detected by culture on buffered charcoal yeast extract (BCYE) agar. Legionellae require the presence of cysteine to grow and therefore do not grow on common blood agar media used for laboratory based total viable counts or on site displides. Common laboratory procedures for the detection of Legionella in water[4] concentrate the bacteria (by centrifugation and/or filtration through 0.2 micron filters) before innoculation onto a charcoal yeast extract agar containing antibiotics (e.g. glycine vancomycim polymixin cyclohexamide, GVPC) to suppress other flora in the sample. Heat or acid treatment are also used to reduce interference from other microbes in the sample.
After incubation for up to 10 days, suspect colonies are confirmed as Legionellae if they grow on BCYE containing cysteine, but not on agar without cysteine added. Immunological techniques are then commonly used to establish the species and/or serogroups of bacteria present in the sample.
New techniques for the rapid detection of Legionella in water samples are emerging including the use of polymerase chain reaction (PCR)[5] and rapid immunological assays[6]. These technologies can typically provide much faster results.
Pathogenesis
Legionella have been known for some time to live within amoebae in the natural environment.[7] Legionella species are the causative agent of the human Legionnaires' disease and the lesser form, Pontiac fever. Legionella transmission is via aerosols—the inhalation of mist droplets containing the bacteria. Common sources include cooling towers, domestic hot-water systems, fountains, and similar disseminators that tap into a public water supply. Natural sources of Legionella include freshwater ponds and creeks. Person-to-person transmission of Legionella has not been demonstrated.[8]
Once inside a host, incubation may take up to two weeks. Initial symptoms are flu-like, including fever, chills, and dry cough. Advanced stages of the disease cause problems with the gastrointestinal tract and the nervous system and lead to diarrhea and nausea. Other advanced symptoms of pneumonia may also present.
However, the disease is generally not a threat to most healthy individuals, and tends to lead to harmful symptoms only in those with a compromised immune system and the elderly. Consequently, it is actively checked for in the water systems of hospitals and nursing homes. In the United States, the disease affects between 8,000 to 18,000 individuals a year.
Molecular biology
With the application of modern molecular genetic and cell biological techniques, the mechanisms used by Legionella to multiply within macrophages are beginning to be understood. The specific regulatory cascades that govern differentiation as well as the gene regulation are being studied. The genome sequences of four L. pneumophila strains have been published and it is now possible to investigate the whole genome by modern molecular methods. The molecular studies are contributing to the fields of clinical research, diagnosis, treatment, epidemiology, and prevention of disease.[2]
Controlling potential sources of Legionella
Common sources of Legionella include cooling towers used in industrial cooling water systems as well as in large central air conditioning systems, domestic hot water systems, fountains, and similar disseminators that draw upon a public water supply. Natural sources include freshwater ponds and creeks.
Recent research in the Journal of Infectious Diseases provides evidence that Legionella pneumophila, the causative agent of Legionnaires disease, can travel at least 6 km from its source by airborne spread. It was previously believed that transmission of the bacterium was restricted to much shorter distances. A team of French scientists reviewed the details of an epidemic of Legionnaires disease that took place in Pas-de-Calais in northern France in 2003–2004. There were 86 confirmed cases during the outbreak, of whom 18 perished. The source of infection was identified as a cooling tower in a petrochemical plant, and an analysis of those affected in the outbreak revealed that some infected people lived as far as 6–7 km from the plant.[9]
Several European countries established a working group known as the European Working Group for Legionella Infections (EWGLI)[10] to share knowledge and experience about monitoring potential sources of Legionella. That group has published guidelines about the actions to be taken to limit the number of colony forming units (i.e. live bacteria that are able to multiply) of Legionella per litre
Legionella bacteria cfu/litre | Action required - 35 samples per facility is required, 20 water / 10 swabs |
---|---|
1000 or less | System under control. (150+ CFU/ml in healthcare facilities or nursing homes require immediate action) |
more than 1000 up to 10,000 |
Review program operation. The count should be confirmed by immediate re-sampling. If a similar count is found again, a review of the control measures and risk assessment should be carried out to identify any remedial actions. |
more than 10,000 | Implement corrective action. The system should immediately be re-sampled. It should then be ‘shot dosed’ with an appropriate biocide, as a precaution. The risk assessment and control measures should be reviewed to identify remedial actions. |
Temperature affects the survival of Legionellae as follows:
- 70 to 80 °C (158 to 176 °F) - Disinfection range
- At 66 °C (151 °F) - Legionellae die within 2 minutes
- At 60 °C (140 °F) - Legionellae die within 32 minutes
- At 55 °C (131 °F) - Legionellae die within 5 to 6 hours
- 50 to 55 °C (122 to 131 °F) - They can survive but do not multiply
- 20 to 50 °C (68 to 122 °F)- Legionellae growth range
- 35 to 46 °C (95 to 115 °F) - Ideal growth range
- Below 20 °C (68 °F) - Legionellae can survive but are dormant
The above data can be confirmed in an online article by Reliance World Wide.[11]
Control of Legionella growth can be through : A. Chemical Treatment 1. Short term - Cl2, must be repeated every 3 to 5 weeks, corrosion factors 2. Long term - ClO2, takes up to 1 month for system saturation B. Non-Chemical Treatment 1. Short term - Thermal eradication - must be repeated every 3 to 5 weeks 2. Long term - Industrial size copper silver ionisation (Ionization) technology such as 1-AquaLyse.ca, 2-Liquitech or 3-TarnPure.
Units have provisional EPA approval. No copper-silver has yet had efficacy data approved by EPA or received final EPA approval.
Guidelines for control of Legionella in cooling towers
Many governmental agencies, cooling tower manufacturers and industrial trade organizations have developed design and maintenance guidelines for preventing or controlling the growth of Legionella in cooling towers. Below is a list of sources for such guidelines:
- [2]
- [3] Legionella control in Ornamental Fountains
- [4] ASHRAE Guideline
- Centers for Disease Control and Prevention - Procedure for Cleaning Cooling Towers and Related Equipment (pages 239 and 240 of 249)
- Cooling Technology Institute - Best Practices for Control of Legionella
- Association of Water Technologies - Legionella 2003
- California Energy Commission - Cooling Water Management Program Guidelines For Wet and Hybrid Cooling Towers at Power Plants
- Marley Cooling Technologies - Cooling Towers Maintenance Procedures
- Marley Cooling Technologies - ASHRAE Guideline 12-2000 - Minimizing the Risk of Legionellosis
- Marley Cooling Technologies - Cooling Tower Inspection Tips {especially page 3 of 7}
- [5] - TEC: Cooling tower company with all certificates needed for handling legionalla
- Tower Tech Modular Cooling Towers - Legionella Control
- GE Infrastructure Water & Process Technologies - Chemical Water Treatment Recommendations For Reduction of Risks Associated with Legionella in Open Recirculating Cooling Water Systems
References
- ↑ Ryan KJ; Ray CG (editors) (2004). Sherris Medical Microbiology (4th Edition ed.). McGraw Hill. ISBN 0-8385-8529-9.
- ↑ 2.0 2.1 Heuner K, Swanson M (editors). (2008). Legionella: Molecular Microbiology. Caister Academic Press. ISBN 978-1-904455-26-4 .
- ↑ Lawrence K. Altman (09-01-2006). "In Philadelphia 30 Years Ago, an Eruption of Illness and Fear". New York Times. Check date values in:
|date=
(help) - ↑ ISO 11731
- ↑ Biologie moléculaire, diagnostic moléculaire, microbiologie, biotechnologies
- ↑ Legionella Field Test - Products - Hydrosense
- ↑ Swanson M, Hammer B (2000). "Legionella pneumophila pathogesesis: a fateful journey from amoebae to macrophages". Annu Rev Microbiol. 54: 567–613. PMID 11018138.
- ↑ Winn, W.C. Jr. (1996). Legionella (In: Baron's Medical Microbiology, Baron, S. et al, eds (4th Edition ed.). University of Texas Medical Branch. ISBN 0-9631172-1-1.(via NCBI Bookshelf)
- ↑ Nguyen T, Ilef D, Jarraud S, Rouil L, Campese C, Che D, Haeghebaert S, Ganiayre F, Marcel F, Etienne J, Desenclos J (2006). "A community-wide outbreak of legionnaires disease linked to industrial cooling towers--how far can contaminated aerosols spread?". J Infect Dis. 193 (1): 102–11. PMID 16323138.
- ↑ European Working Group for Legionella Infections
- ↑ What is Legionnaires' Disease?
See also
- Legionella pneumophila
- Biocide
- Legionellosis
- European Working Group for Legionella Infections
- Environmental microbiology
External links
- CDC Division of bacterial and Mycotic Diseases: Legionellosis
- Directors of Health Promotion and Education page on Legionellosis
- European Working Group for Legionella Infections
- Recent outbreaks of Legionnaires' Disease
- Legionnaires' disease Outbreaks
- ASHRAE Guideline
- NUCLEAGENA: Polish company for the detection of Legionella