Portal hypertension echocardiography and ultrasound: Difference between revisions
No edit summary |
|||
Line 5: | Line 5: | ||
==Overview== | ==Overview== | ||
[[Doppler echocardiography|Echo-Doppler]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler echocardiography|echo-doppler]] suggestive of portal hypertension include lack of increase in [[portal vein]] diameter in response to meals, increased portal [[blood flow]] velocity, and decreased [[portal vein]] cross-sectional area. [[Doppler ultrasonography|Color-Doppler ultrasound]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler ultrasonography|color-doppler ultrasound]] suggestive of portal hypertension include increased diameter of [[left gastric vein]], increased diameter of [[portal vein]], and increased flow velocity in [[left gastric vein]]. | [[Doppler echocardiography|Echo-Doppler]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler echocardiography|echo-doppler]] suggestive of portal hypertension include lack of increase in [[portal vein]] diameter in response to meals, increased portal [[blood flow]] velocity, and decreased [[portal vein]] cross-sectional area. [[Doppler ultrasonography|Color-Doppler ultrasound]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler ultrasonography|color-doppler ultrasound]] suggestive of portal hypertension include increased diameter of [[left gastric vein]], increased diameter of [[portal vein]], and increased flow velocity in [[left gastric vein]]. [[Biphasic]] and reverse flow in [[portal vein]] along with re-canalization of [[umbilical vein]] are [[pathognomonic]] for portal hypertension. | ||
==Echocardiography/Ultrasound== | ==Echocardiography/Ultrasound== | ||
{|align= "right" | {| align="right" | ||
|{{#ev:youtube|lKkmWFm6xSw|500}} | |{{#ev:youtube|lKkmWFm6xSw|500}} | ||
|} | |} | ||
=== Echo-Doppler === | |||
*[[Doppler echocardiography|Echo-Doppler]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler echocardiography|echo-doppler]] suggestive of portal hypertension include: | *[[Doppler echocardiography|Echo-Doppler]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler echocardiography|echo-doppler]] suggestive of portal hypertension include: | ||
**Lack of increase in [[portal vein]] diameter in response to meals | **Lack of increase in [[portal vein]] diameter in response to meals | ||
Line 16: | Line 18: | ||
**Decreased [[portal vein]] cross-sectional area<ref name="pmid1447502">{{cite journal |vauthors=Sabbà C, Ferraioli G, Buonamico P, Berardi E, Antonica G, Taylor KJ, Albano O |title=Echo-Doppler evaluation of acute flow changes in portal hypertensive patients: flow velocity as a reliable parameter |journal=J. Hepatol. |volume=15 |issue=3 |pages=356–60 |year=1992 |pmid=1447502 |doi= |url=}}</ref> | **Decreased [[portal vein]] cross-sectional area<ref name="pmid1447502">{{cite journal |vauthors=Sabbà C, Ferraioli G, Buonamico P, Berardi E, Antonica G, Taylor KJ, Albano O |title=Echo-Doppler evaluation of acute flow changes in portal hypertensive patients: flow velocity as a reliable parameter |journal=J. Hepatol. |volume=15 |issue=3 |pages=356–60 |year=1992 |pmid=1447502 |doi= |url=}}</ref> | ||
=== Color-Doppler Ultrasound === | |||
*[[Doppler ultrasonography|Color-Doppler ultrasound]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler ultrasonography|color-doppler ultrasound]] suggestive of portal hypertension include:<ref name="pmid11180179">{{cite journal |vauthors=Yin XY, Lu MD, Huang JF, Xie XY, Liang LJ |title=Color Doppler velocity profile assessment of portal hemodynamics in cirrhotic patients with portal hypertension: correlation with esophageal variceal bleeding |journal=J Clin Ultrasound |volume=29 |issue=1 |pages=7–13 |year=2001 |pmid=11180179 |doi= |url=}}</ref> | *[[Doppler ultrasonography|Color-Doppler ultrasound]] may be helpful in the diagnosis of portal hypertension. Findings on an [[Doppler ultrasonography|color-doppler ultrasound]] suggestive of portal hypertension include:<ref name="pmid11180179">{{cite journal |vauthors=Yin XY, Lu MD, Huang JF, Xie XY, Liang LJ |title=Color Doppler velocity profile assessment of portal hemodynamics in cirrhotic patients with portal hypertension: correlation with esophageal variceal bleeding |journal=J Clin Ultrasound |volume=29 |issue=1 |pages=7–13 |year=2001 |pmid=11180179 |doi= |url=}}</ref> | ||
**Increased diameter of [[left gastric vein]] | **Increased diameter of [[left gastric vein]] | ||
**Increased diameter of [[portal vein]] | **Increased diameter of [[portal vein]] | ||
**Increased flow velocity in [[left gastric vein]] | **Increased flow velocity in [[left gastric vein]] | ||
**[[Biphasic]] and reverse flow in [[portal vein]] -- [[pathognomonic]] of portal hypertension<ref name="urlPortal hypertension | Radiology Reference Article | Radiopaedia.org">{{cite web |url=https://radiopaedia.org/articles/portal-hypertension |title=Portal hypertension | Radiology Reference Article | Radiopaedia.org |format= |work= |accessdate=}}</ref> | |||
**Diameter and velocity in [[left gastric vein]] are significantly associated with incident of [[esophageal varices]]<ref name="pmid16052688">{{cite journal| author=Li FH, Hao J, Xia JG, Li HL, Fang H| title=Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound. | journal=World J Gastroenterol | year= 2005 | volume= 11 | issue= 29 | pages= 4560-5 | pmid=16052688 | doi= | pmc=4398708 | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=16052688 }}</ref> | |||
** | === Ultrasonography === | ||
*[[Ultrasonography]] may be helpful in the diagnosis of portal hypertension. Findings on an [[abdominal]] [[ultrasonography]] suggestive of portal hypertension include: | |||
**[[Splenomegaly]] | |||
**[[Ascites]] | |||
**Re-canalization of [[umbilical vein]] -- [[pathognomonic]] of portal hypertension<ref name="urlPortal hypertension | Radiology Reference Article | Radiopaedia.org" /> | |||
**Porto-systemic [[collaterals]] | |||
==References== | ==References== |
Revision as of 15:49, 6 November 2017
Portal Hypertension Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Portal hypertension echocardiography and ultrasound On the Web |
American Roentgen Ray Society Images of Portal hypertension echocardiography and ultrasound |
Portal hypertension echocardiography and ultrasound in the news |
Blogs on Portal hypertension echocardiography and ultrasound |
Risk calculators and risk factors for Portal hypertension echocardiography and ultrasound |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Eiman Ghaffarpasand, M.D. [2]
Overview
Echo-Doppler may be helpful in the diagnosis of portal hypertension. Findings on an echo-doppler suggestive of portal hypertension include lack of increase in portal vein diameter in response to meals, increased portal blood flow velocity, and decreased portal vein cross-sectional area. Color-Doppler ultrasound may be helpful in the diagnosis of portal hypertension. Findings on an color-doppler ultrasound suggestive of portal hypertension include increased diameter of left gastric vein, increased diameter of portal vein, and increased flow velocity in left gastric vein. Biphasic and reverse flow in portal vein along with re-canalization of umbilical vein are pathognomonic for portal hypertension.
Echocardiography/Ultrasound
lKkmWFm6xSw|500}} |
Echo-Doppler
- Echo-Doppler may be helpful in the diagnosis of portal hypertension. Findings on an echo-doppler suggestive of portal hypertension include:
- Lack of increase in portal vein diameter in response to meals
- Increased portal blood flow velocity
- Decreased portal vein cross-sectional area[1]
Color-Doppler Ultrasound
- Color-Doppler ultrasound may be helpful in the diagnosis of portal hypertension. Findings on an color-doppler ultrasound suggestive of portal hypertension include:[2]
- Increased diameter of left gastric vein
- Increased diameter of portal vein
- Increased flow velocity in left gastric vein
- Biphasic and reverse flow in portal vein -- pathognomonic of portal hypertension[3]
- Diameter and velocity in left gastric vein are significantly associated with incident of esophageal varices[4]
Ultrasonography
- Ultrasonography may be helpful in the diagnosis of portal hypertension. Findings on an abdominal ultrasonography suggestive of portal hypertension include:
- Splenomegaly
- Ascites
- Re-canalization of umbilical vein -- pathognomonic of portal hypertension[3]
- Porto-systemic collaterals
References
- ↑ Sabbà C, Ferraioli G, Buonamico P, Berardi E, Antonica G, Taylor KJ, Albano O (1992). "Echo-Doppler evaluation of acute flow changes in portal hypertensive patients: flow velocity as a reliable parameter". J. Hepatol. 15 (3): 356–60. PMID 1447502.
- ↑ Yin XY, Lu MD, Huang JF, Xie XY, Liang LJ (2001). "Color Doppler velocity profile assessment of portal hemodynamics in cirrhotic patients with portal hypertension: correlation with esophageal variceal bleeding". J Clin Ultrasound. 29 (1): 7–13. PMID 11180179.
- ↑ 3.0 3.1 "Portal hypertension | Radiology Reference Article | Radiopaedia.org".
- ↑ Li FH, Hao J, Xia JG, Li HL, Fang H (2005). "Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound". World J Gastroenterol. 11 (29): 4560–5. PMC 4398708. PMID 16052688.