In [[nephrology]], the '''peritoneal equilibration test''' (PET), is a tool used by [[nephrologist]]s to determine the characteristics of the [[peritoneal]] membrane | In [[nephrology]], the '''peritoneal equilibration test''' (PET), is a tool used by [[nephrologist]]s to determine the characteristics of the [[peritoneal]] membrane mass transport characteristics, when assessing a patient for [[peritoneal dialysis]]. | ||
==Definition== | ==Definition== | ||
The peritoneal equilibration test (PET) is a semiquantitative assessment of peritoneal membrane transport function in patients on peritoneal dialysis (PD). The solute transport rates are assessed by the rates of their equilibration between the peritoneal capillary blood and dialysate. The ratio of solute concentrations in dialysate and plasma (D/P ratio) at specific times (t) during the dwell signifies the extent of solute equilibration. This ratio can be determined for any solute that is transported from the capillary blood to the dialysate. Creatinine, urea, electrolytes, phosphate, and proteins are the commonly tested solutes for clinical use.<ref>{{cite journal | author = Pannekeet M, Imholz A, Struijk D, Koomen G, Langedijk M, Schouten N, de Waart R, Hiralall J, Krediet R | title = The standard peritoneal permeability analysis: a tool for the assessment of peritoneal permeability characteristics in CAPD patients. | journal = Kidney Int | volume = 48 | issue = 3 | pages = 866-75 | year = 1995 | id = PMID 7474677}}</ref> | The peritoneal equilibration test (PET) is a semiquantitative assessment of peritoneal membrane transport function in patients on peritoneal dialysis (PD). The solute transport rates are assessed by the rates of their equilibration between the peritoneal capillary blood and dialysate. The ratio of solute concentrations in dialysate and plasma (D/P ratio) at specific times (t) during the dwell signifies the extent of solute equilibration. This ratio can be determined for any solute that is transported from the capillary blood to the dialysate. Creatinine, urea, electrolytes, phosphate, and proteins are the commonly tested solutes for clinical use.<ref>{{cite journal | author = Pannekeet M, Imholz A, Struijk D, Koomen G, Langedijk M, Schouten N, de Waart R, Hiralall J, Krediet R | title = The standard peritoneal permeability analysis: a tool for the assessment of peritoneal permeability characteristics in CAPD patients. | journal = Kidney Int | volume = 48 | issue = 3 | pages = 866-75 | year = 1995 | id = PMID 7474677}}</ref> |
Revision as of 13:30, 14 May 2009
Please Take Over This Page and Apply to be Editor-In-Chief for this topic: There can be one or more than one Editor-In-Chief. You may also apply to be an Associate Editor-In-Chief of one of the subtopics below. Please mail us [1] to indicate your interest in serving either as an Editor-In-Chief of the entire topic or as an Associate Editor-In-Chief for a subtopic. Please be sure to attach your CV and or biographical sketch.
In nephrology, the peritoneal equilibration test (PET), is a tool used by nephrologists to determine the characteristics of the peritoneal membrane mass transport characteristics, when assessing a patient for peritoneal dialysis.
Definition
The peritoneal equilibration test (PET) is a semiquantitative assessment of peritoneal membrane transport function in patients on peritoneal dialysis (PD). The solute transport rates are assessed by the rates of their equilibration between the peritoneal capillary blood and dialysate. The ratio of solute concentrations in dialysate and plasma (D/P ratio) at specific times (t) during the dwell signifies the extent of solute equilibration. This ratio can be determined for any solute that is transported from the capillary blood to the dialysate. Creatinine, urea, electrolytes, phosphate, and proteins are the commonly tested solutes for clinical use.[1]