Atrioventricular block pathophysiology: Difference between revisions
No edit summary |
|||
Line 7: | Line 7: | ||
==Pathophysiology== | ==Pathophysiology== | ||
Atrioventricular (AV) block is caused by one of the following mechanisms i.e. fibrosis or degeneration of the conduction system, [[ischemic heart disease]], or medications. AV block is categorized by degree and site of conduction block. In first-degree AV block, all atrial impulses are conducted to the ventricle. However, there is a delay within the AV node, resulting in a prolonged PR interval on ECG (>200 msec or >5 small blocks). Second-degree AV block can be of one of the two types: Mobitz I and Mobitz II. Mobitz I, or [[Wenckebach block]] , consists of progressive prolongation of PR interval, until loss of conduction to the ventricle occurs (missed beat). Mobitz I block is rarely symptomatic and does not require treatment. On the other hand, Mobitz II AV block is characterized by a constant PR interval with intermittent missed beats. The missed beats can occur with varying frequency such as occasional to 3:1 or 2:1. [[Complete heart block]] (third-degree heart block) is characterized by a complete lack of conduction from the atria to the ventricles. The ventricular rates in complete heart blocks are slower than the atrial rate. A junctional escape rate is generally between 40 and 60 beats/min and shows narrow QRS complex on EKG, whereas a ventricular escape rate is slower with a wide QRS complex | Atrioventricular (AV) block is caused by one of the following mechanisms i.e. fibrosis or degeneration of the conduction system, [[ischemic heart disease]], or medications. AV block is categorized by degree and site of conduction block. In first-degree AV block, all atrial impulses are conducted to the ventricle. However, there is a delay within the AV node, resulting in a prolonged PR interval on ECG (>200 msec or >5 small blocks). Second-degree AV block can be of one of the two types: Mobitz I and Mobitz II. Mobitz I, or [[Wenckebach block]] , consists of progressive prolongation of PR interval, until loss of conduction to the ventricle occurs (missed beat). Mobitz I block is rarely symptomatic and does not require treatment. On the other hand, Mobitz II AV block is characterized by a constant PR interval with intermittent missed beats. The missed beats can occur with varying frequency such as occasional to 3:1 or 2:1. [[Complete heart block]] (third-degree heart block) is characterized by a complete lack of conduction from the atria to the ventricles. The ventricular rates in complete heart blocks are slower than the atrial rate. A junctional escape rate is generally between 40 and 60 beats/min and shows narrow QRS complex on EKG, whereas a ventricular escape rate is slower with a wide QRS complex. | ||
==References== | ==References== | ||
{{Reflist|2}} | {{Reflist|2}} | ||
[[Category:Needs content]] | [[Category:Needs content]] |
Revision as of 12:56, 27 August 2012
Atrioventricular block Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Atrioventricular block pathophysiology On the Web |
American Roentgen Ray Society Images of Atrioventricular block pathophysiology |
Risk calculators and risk factors for Atrioventricular block pathophysiology |
Please help WikiDoc by adding more content here. It's easy! Click here to learn about editing.
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Overview
Pathophysiology
Atrioventricular (AV) block is caused by one of the following mechanisms i.e. fibrosis or degeneration of the conduction system, ischemic heart disease, or medications. AV block is categorized by degree and site of conduction block. In first-degree AV block, all atrial impulses are conducted to the ventricle. However, there is a delay within the AV node, resulting in a prolonged PR interval on ECG (>200 msec or >5 small blocks). Second-degree AV block can be of one of the two types: Mobitz I and Mobitz II. Mobitz I, or Wenckebach block , consists of progressive prolongation of PR interval, until loss of conduction to the ventricle occurs (missed beat). Mobitz I block is rarely symptomatic and does not require treatment. On the other hand, Mobitz II AV block is characterized by a constant PR interval with intermittent missed beats. The missed beats can occur with varying frequency such as occasional to 3:1 or 2:1. Complete heart block (third-degree heart block) is characterized by a complete lack of conduction from the atria to the ventricles. The ventricular rates in complete heart blocks are slower than the atrial rate. A junctional escape rate is generally between 40 and 60 beats/min and shows narrow QRS complex on EKG, whereas a ventricular escape rate is slower with a wide QRS complex.