Congenital heart disease laboratory findings: Difference between revisions
Jump to navigation
Jump to search
(Created page with "__NOTOC__ {{Congenital heart disease}} {{CMG}} '''Associate Editor-In-Chief:''' Keri Shafer, M.D. [mailto:kshafer@bidmc.harvard.edu], Atif Mohammad, M.D....") |
No edit summary |
||
Line 11: | Line 11: | ||
Lab Studies in Congenital heart disease <ref> Braunwald Zipes Libby. Heart disease: A textbook of cardiovascular medicine, 6th Edition chapter 43:W.B. Saunders ;.pp 1523</ref> | Lab Studies in Congenital heart disease <ref> Braunwald Zipes Libby. Heart disease: A textbook of cardiovascular medicine, 6th Edition chapter 43:W.B. Saunders ;.pp 1523</ref> | ||
* | * [[Erythrocytosis]]: Seen in cyanotic congenital heart disease | ||
* | * [[Hb]] > 20gm/dl: Seen in cyanotic congenital heart disease] | ||
* | *Checking oxygen levels in the blood using an arterial blood gas test or by checking it through the skin with a [[pulse oximeter]] | ||
* | *[[Complete blood count]] (CBC) | ||
* | * Hyperoxia test: A '''hyperoxia test''' is a test that is performed--usually on an infant-- to determine whether the patient's [[cyanosis]] is due to lung disease or a problem with blood circulation.<ref name=Nadas>{{cite book|last=Fyler|first=edited by John F. Keane, James E. Lock, Donald C.|title=Nadas' pediatric cardiology|year=2006|publisher=Saunders [u.a.]|location=Philadelphia [u.a.]|isbn=978-1-4160-2390-6|edition=2nd ed.|url=http://www.mdconsult.com/books/page.do?eid=4-u1.0-B978-1-4160-2390-6..50016-7--cesec22&isbn=978-1-4160-2390-6&sid=1223957161&uniqId=288314811-3#4-u1.0-B978-1-4160-2390-6..50016-7--cesec31}}</ref><sup></sup><ref name=pedsed>{{cite web|url=http://www.pediatriceducation.org/2006/01/23/ |title=When Do Cyanotic Congenital Heart Diseases Present? |publisher=Pediatric Education |date=2006-01-23 |accessdate=2011-10-26}}</ref> It is performed by measuring the [[arterial blood gases]] of the patient while he breathes room air, then re-measuring the blood gases after the patient has breathed 100% oxygen for 10 minutes.<ref name=Nadas></ref><sup></sup><ref name=PedsOnCall>{{cite web|author=Dr. Ira Shah |url=http://www.pediatriconcall.com/fordoctor/Conference_abstracts/Blue_baby.asp |title=How To Manage Blue Baby Maha Neocon 2005 pediatric oncall |publisher=Pediatriconcall.com |date=2006-02-15 |accessdate=2011-10-26}}</ref> If the cause of the cyanosis is due to poor oxygen saturation by the lungs, allowing the patient to breath 100% O2 will augment the lungs' ability to saturate the blood with oxygen, and the [[partial pressure]] of oxygen in the arterial blood will rise (usually above 150 [[mmHg]]<ref name=PedsOnCall />). However, if the lungs are healthy and already fully saturating the blood that is delivered to them, then supplemental oxygen will have no effect, and the partial pressure of oxygen will usually remain below 100mmHg.<ref name=PedsOnCall/> In this case, the cyanosis is most likely due to blood that moves from the systemic veins to the systemic arteries via a [[right-to-left shunt]] without ever going through the lungs.<ref name=Nadas/><sup></sup> | ||
==References== | ==References== |
Revision as of 16:44, 19 October 2012
Congenital heart disease Microchapters |
Differentiating Congenital heart disease from other Disorders |
---|
Diagnosis |
Treatment |
Case Studies |
Congenital heart disease laboratory findings On the Web |
American Roentgen Ray Society Images of Congenital heart disease laboratory findings |
Risk calculators and risk factors for Congenital heart disease laboratory findings |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Associate Editor-In-Chief: Keri Shafer, M.D. [2], Atif Mohammad, M.D., Priyamvada Singh, MBBS
Overview
Laboratory Findings
Lab Studies in Congenital heart disease [1]
- Erythrocytosis: Seen in cyanotic congenital heart disease
- Hb > 20gm/dl: Seen in cyanotic congenital heart disease]
- Checking oxygen levels in the blood using an arterial blood gas test or by checking it through the skin with a pulse oximeter
- Complete blood count (CBC)
- Hyperoxia test: A hyperoxia test is a test that is performed--usually on an infant-- to determine whether the patient's cyanosis is due to lung disease or a problem with blood circulation.[2][3] It is performed by measuring the arterial blood gases of the patient while he breathes room air, then re-measuring the blood gases after the patient has breathed 100% oxygen for 10 minutes.[2][4] If the cause of the cyanosis is due to poor oxygen saturation by the lungs, allowing the patient to breath 100% O2 will augment the lungs' ability to saturate the blood with oxygen, and the partial pressure of oxygen in the arterial blood will rise (usually above 150 mmHg[4]). However, if the lungs are healthy and already fully saturating the blood that is delivered to them, then supplemental oxygen will have no effect, and the partial pressure of oxygen will usually remain below 100mmHg.[4] In this case, the cyanosis is most likely due to blood that moves from the systemic veins to the systemic arteries via a right-to-left shunt without ever going through the lungs.[2]
References
- ↑ Braunwald Zipes Libby. Heart disease: A textbook of cardiovascular medicine, 6th Edition chapter 43:W.B. Saunders ;.pp 1523
- ↑ 2.0 2.1 2.2 Fyler, edited by John F. Keane, James E. Lock, Donald C. (2006). Nadas' pediatric cardiology (2nd ed. ed.). Philadelphia [u.a.]: Saunders [u.a.] ISBN 978-1-4160-2390-6.
- ↑ "When Do Cyanotic Congenital Heart Diseases Present?". Pediatric Education. 2006-01-23. Retrieved 2011-10-26.
- ↑ 4.0 4.1 4.2 Dr. Ira Shah (2006-02-15). "How To Manage Blue Baby Maha Neocon 2005 pediatric oncall". Pediatriconcall.com. Retrieved 2011-10-26.
de:Herzfehler
lv:Iedzimtās sirds slimības
nn:Medfødd hjartefeil
sr:Урођене срчане мане
uk:Вроджені вади серця
wa:Maladeye des bleus påpåds