==Restenosis== | ==Restenosis== | ||
In the setting of in-[[stent]] restenosis (ISR) after [[bare metal stent|bare metal stent (BMS)]] implantation, the risk of recurrence can be predicted by the pattern of restenosis. | *[[Restenosis]] can occur in the implanted [[stent]] after performing [[PCI]].<ref name="pmid34895950">{{cite journal| author=Writing Committee Members. Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM | display-authors=etal| title=2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. | journal=J Am Coll Cardiol | year= 2022 | volume= 79 | issue= 2 | pages= e21-e129 | pmid=34895950 | doi=10.1016/j.jacc.2021.09.006 | pmc= | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=34895950 }} </ref> | ||
*Factors such as [[stent]] type, chosen procedure, and [[patient]]-related factors are critical in the [[pathophysiology]] of [[stent]] [[thrombosis]] or [[restenosis]].<ref name="pmid21109112">{{cite journal| author=Dangas GD, Claessen BE, Caixeta A, Sanidas EA, Mintz GS, Mehran R| title=In-stent restenosis in the drug-eluting stent era. | journal=J Am Coll Cardiol | year= 2010 | volume= 56 | issue= 23 | pages= 1897-907 | pmid=21109112 | doi=10.1016/j.jacc.2010.07.028 | pmc= | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=21109112 }} </ref><ref name="pmid20946992">{{cite journal| author=Holmes DR, Kereiakes DJ, Garg S, Serruys PW, Dehmer GJ, Ellis SG | display-authors=etal| title=Stent thrombosis. | journal=J Am Coll Cardiol | year= 2010 | volume= 56 | issue= 17 | pages= 1357-65 | pmid=20946992 | doi=10.1016/j.jacc.2010.07.016 | pmc= | url=https://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=20946992 }} </ref> | |||
*In the setting of in-[[stent]] [[restenosis]] (ISR) after [[bare metal stent|bare metal stent (BMS)]] implantation, the risk of recurrence can be predicted by the pattern of [[restenosis]]. | |||
===Classification=== | ===Classification=== | ||
''Table 1. Mehran Classification System<ref name="pmid10545431">{{cite journal| author=Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al.| title=Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. | journal=Circulation | year= 1999 | volume= 100 | issue= 18 | pages= 1872-8 | pmid=10545431 | doi= | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=10545431 }} </ref>'' | ''Table 1. Mehran Classification System<ref name="pmid10545431">{{cite journal| author=Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al.| title=Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. | journal=Circulation | year= 1999 | volume= 100 | issue= 18 | pages= 1872-8 | pmid=10545431 | doi= | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=10545431 }} </ref>'' | ||
* Pattern I: Focal (≤ 10 mm in length) [[lesion]]s | * Pattern I: Focal (≤ 10 mm in length) [[lesion]]s | ||
** Ia : Restenosis within the [[stent]] | ** Ia : [[Restenosis]] within the [[stent]] | ||
** Ib : Restenosis at the edge of the [[stent]] | ** Ib : [[Restenosis]] at the edge of the [[stent]] | ||
** Ic : Restenosis at the articulation or gap | ** Ic : [[Restenosis]] at the articulation or gap | ||
** Id : Restenosis multifocal | ** Id : [[Restenosis]] multifocal | ||
* Pattern II: ISR >10 mm within the [[stent]] | * Pattern II: ISR >10 mm within the [[stent]] | ||
* Pattern III: Includes ISR > 10 mm extending outside the [[stent]] | * Pattern III: Includes ISR > 10 mm extending outside the [[stent]] | ||
* Pattern IV: ISR totally occluded | * Pattern IV: ISR totally occluded | ||
===Implications=== | ===Implications=== | ||
*The need for recurrent target [[lesion]] [[revascularization]] (TLR) increased with increasing ISR class, increasing from 19%, 35%, 50%, to 83% in classes I to IV, respectively (P <0.001)<ref name="pmid10545431">{{cite journal| author=Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al.| title=Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. | journal=Circulation | year= 1999 | volume= 100 | issue= 18 | pages= 1872-8 | pmid=10545431 | doi= | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=10545431 }} </ref>. | |||
The need for recurrent target [[lesion]] [[revascularization]] (TLR) increased with increasing ISR class, increasing from 19%, 35%, 50%, to 83% in classes I to IV, respectively (P <0.001)<ref name="pmid10545431">{{cite journal| author=Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al.| title=Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. | journal=Circulation | year= 1999 | volume= 100 | issue= 18 | pages= 1872-8 | pmid=10545431 | doi= | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=10545431 }} </ref>. | *[[Restenosis]] after [[DES|drug eluting stent]] implantation is generally more focal than following [[bare metal stent]] placement<ref name="pmid15596568">{{cite journal| author=Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M et al.| title=Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. | journal=Circulation | year= 2004 | volume= 110 | issue= 25 | pages= 3773-80 | pmid=15596568 | doi=10.1161/01.CIR.0000150331.14687.4B | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=15596568 }} </ref><ref name="pmid12719283">{{cite journal| author=Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M et al.| title=Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. | journal=Circulation | year= 2003 | volume= 107 | issue= 17 | pages= 2178-80 | pmid=12719283 | doi=10.1161/01.CIR.0000070592.04766.36 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12719283 }} </ref>, and, with the [[sirolimus eluting stent]], more is commonly at the margin of the [[stent]] due to [[balloon]] injury that is not covered with [[stent]]<ref name="pmid15596568">{{cite journal| author=Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M et al.| title=Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. | journal=Circulation | year= 2004 | volume= 110 | issue= 25 | pages= 3773-80 | pmid=15596568 | doi=10.1161/01.CIR.0000150331.14687.4B | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=15596568 }} </ref><ref name="pmid12719283">{{cite journal| author=Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M et al.| title=Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. | journal=Circulation | year= 2003 | volume= 107 | issue= 17 | pages= 2178-80 | pmid=12719283 | doi=10.1161/01.CIR.0000070592.04766.36 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12719283 }} </ref><ref name="pmid12860901">{{cite journal| author=Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K et al.| title=Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. | journal=Circulation | year= 2003 | volume= 108 | issue= 3 | pages= 257-60 | pmid=12860901 | doi=10.1161/01.CIR.0000083366.33686.11 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12860901 }} </ref>. | ||
Restenosis after [[DES|drug eluting stent]] implantation is generally more focal than following [[bare metal stent]] placement<ref name="pmid15596568">{{cite journal| author=Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M et al.| title=Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. | journal=Circulation | year= 2004 | volume= 110 | issue= 25 | pages= 3773-80 | pmid=15596568 | doi=10.1161/01.CIR.0000150331.14687.4B | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=15596568 }} </ref><ref name="pmid12719283">{{cite journal| author=Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M et al.| title=Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. | journal=Circulation | year= 2003 | volume= 107 | issue= 17 | pages= 2178-80 | pmid=12719283 | doi=10.1161/01.CIR.0000070592.04766.36 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12719283 }} </ref>, and, with the [[sirolimus eluting stent]], more is commonly at the margin of the [[stent]] due to [[balloon]] injury that is not covered with [[stent]]<ref name="pmid15596568">{{cite journal| author=Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M et al.| title=Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries. | journal=Circulation | year= 2004 | volume= 110 | issue= 25 | pages= 3773-80 | pmid=15596568 | doi=10.1161/01.CIR.0000150331.14687.4B | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=15596568 }} </ref><ref name="pmid12719283">{{cite journal| author=Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M et al.| title=Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation. | journal=Circulation | year= 2003 | volume= 107 | issue= 17 | pages= 2178-80 | pmid=12719283 | doi=10.1161/01.CIR.0000070592.04766.36 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12719283 }} </ref><ref name="pmid12860901">{{cite journal| author=Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K et al.| title=Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. | journal=Circulation | year= 2003 | volume= 108 | issue= 3 | pages= 257-60 | pmid=12860901 | doi=10.1161/01.CIR.0000083366.33686.11 | pmc= | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=12860901 }} </ref>. | |||
==References== | ==References== |
Revision as of 10:00, 23 June 2022
Percutaneous coronary intervention Microchapters |
PCI Complications |
---|
PCI in Specific Patients |
PCI in Specific Lesion Types |
PCI complications: restenosis On the Web |
American Roentgen Ray Society Images of PCI complications: restenosis |
Directions to Hospitals Treating Percutaneous coronary intervention |
Risk calculators and risk factors for PCI complications: restenosis |
Editors-In-Chief: Alexandra Almonacid M.D.; Jeffrey J. Popma M.D. Associate Editor(s)-in-Chief: Anahita Deylamsalehi, M.D.[1]
Restenosis
- Restenosis can occur in the implanted stent after performing PCI.[1]
- Factors such as stent type, chosen procedure, and patient-related factors are critical in the pathophysiology of stent thrombosis or restenosis.[2][3]
- In the setting of in-stent restenosis (ISR) after bare metal stent (BMS) implantation, the risk of recurrence can be predicted by the pattern of restenosis.
Classification
Table 1. Mehran Classification System[4]
- Pattern I: Focal (≤ 10 mm in length) lesions
- Ia : Restenosis within the stent
- Ib : Restenosis at the edge of the stent
- Ic : Restenosis at the articulation or gap
- Id : Restenosis multifocal
- Pattern II: ISR >10 mm within the stent
- Pattern III: Includes ISR > 10 mm extending outside the stent
- Pattern IV: ISR totally occluded
Implications
- The need for recurrent target lesion revascularization (TLR) increased with increasing ISR class, increasing from 19%, 35%, 50%, to 83% in classes I to IV, respectively (P <0.001)[4].
- Restenosis after drug eluting stent implantation is generally more focal than following bare metal stent placement[5][6], and, with the sirolimus eluting stent, more is commonly at the margin of the stent due to balloon injury that is not covered with stent[5][6][7].
References
- ↑ Writing Committee Members. Lawton JS, Tamis-Holland JE, Bangalore S, Bates ER, Beckie TM; et al. (2022). "2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines". J Am Coll Cardiol. 79 (2): e21–e129. doi:10.1016/j.jacc.2021.09.006. PMID 34895950 Check
|pmid=
value (help). - ↑ Dangas GD, Claessen BE, Caixeta A, Sanidas EA, Mintz GS, Mehran R (2010). "In-stent restenosis in the drug-eluting stent era". J Am Coll Cardiol. 56 (23): 1897–907. doi:10.1016/j.jacc.2010.07.028. PMID 21109112.
- ↑ Holmes DR, Kereiakes DJ, Garg S, Serruys PW, Dehmer GJ, Ellis SG; et al. (2010). "Stent thrombosis". J Am Coll Cardiol. 56 (17): 1357–65. doi:10.1016/j.jacc.2010.07.016. PMID 20946992.
- ↑ 4.0 4.1 Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF; et al. (1999). "Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome". Circulation. 100 (18): 1872–8. PMID 10545431.
- ↑ 5.0 5.1 Popma JJ, Leon MB, Moses JW, Holmes DR, Cox N, Fitzpatrick M; et al. (2004). "Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries". Circulation. 110 (25): 3773–80. doi:10.1161/01.CIR.0000150331.14687.4B. PMID 15596568.
- ↑ 6.0 6.1 Colombo A, Orlic D, Stankovic G, Corvaja N, Spanos V, Montorfano M; et al. (2003). "Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation". Circulation. 107 (17): 2178–80. doi:10.1161/01.CIR.0000070592.04766.36. PMID 12719283.
- ↑ Lemos PA, Saia F, Ligthart JM, Arampatzis CA, Sianos G, Tanabe K; et al. (2003). "Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases". Circulation. 108 (3): 257–60. doi:10.1161/01.CIR.0000083366.33686.11. PMID 12860901.