*In complete heart block because the impulse is blocked, an accessory pacemaker below the level of the block will typically activate the ventricles.  This is known as an escape rhythm. Since this accessory pacemaker activates independently of the impulse generated at the [[SA node]], two independent rhythms can be noted on the [[electrocardiogram]] (EKG).   
*In complete heart block because the impulse is blocked, an accessory pacemaker below the level of the block will typically activate the ventricles.  This is known as an escape rhythm. Since this accessory pacemaker activates independently of the impulse generated at the [[SA node]], two independent rhythms can be noted on the [[electrocardiogram]] (EKG).   
** One will activate the atria and create the P waves, typically with a regular [[PP interval|P to P interval]].  
** One will activate the atria and create the P waves, typically with a regular [[PP interval|P to P interval]].  
** The second will activate the ventricles and produce the QRS complex, typically with a regular R to R interval. The PR interval will be variable, as the hallmark of complete heart block is no apparent relationship between P waves and QRS complexes.
** The second will activate the ventricles and produce the QRS complex, typically with a regular [[RR interval|R to R interval]]. The PR interval will be variable, as the hallmark of complete heart block is no apparent relationship between P waves and QRS complexes.


===Complete Heart Block in Myocardial Infarction===
===Complete Heart Block in Myocardial Infarction===

Revision as of 16:30, 5 February 2013

Third degree AV block Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Third degree AV block from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Study of Choice

History and Symptoms

Physical Examination

Laboratory Findings

Electrocardiogram

X Ray

Echocardiography and Ultrasound

CT scan

MRI

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Third degree AV block pathophysiology On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Third degree AV block pathophysiology

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Third degree AV block pathophysiology

CDC on Third degree AV block pathophysiology

Third degree AV block pathophysiology in the news

Blogs on Third degree AV block pathophysiology

Directions to Hospitals Treating Third degree AV block

Risk calculators and risk factors for Third degree AV block pathophysiology

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Cafer Zorkun, M.D., Ph.D. [2]

Pathophysiology

  • In complete heart block because the impulse is blocked, an accessory pacemaker below the level of the block will typically activate the ventricles. This is known as an escape rhythm. Since this accessory pacemaker activates independently of the impulse generated at the SA node, two independent rhythms can be noted on the electrocardiogram (EKG).
    • One will activate the atria and create the P waves, typically with a regular P to P interval.
    • The second will activate the ventricles and produce the QRS complex, typically with a regular R to R interval. The PR interval will be variable, as the hallmark of complete heart block is no apparent relationship between P waves and QRS complexes.

Complete Heart Block in Myocardial Infarction

  • An inferior wall myocardial infarction may cause damage to the AV node, causing third degree heart block. In this case, the damage is usually transitory, and the AV node may recover. Studies have shown that third degree heart block in the setting of an inferior wall myocardial infarction typically resolves within 2 weeks. The escape rhythm typically originates in the AV junction, producing a narrow complex escape rhythm.
  • An anterior wall myocardial infarction may damage the distal conduction system of the heart, causing third degree heart block. This is typically extensive, permanent damage to the conduction system, necessitating a permanent pacemaker to be placed. The escape rhythm typically originates in the ventricles, producing a wide complex escape rhythm.