Radial catheterization pitfalls: Difference between revisions

Jump to navigation Jump to search
Line 21: Line 21:
* High origin radial artery.
* High origin radial artery.


A lot of techniques has been used to overcome tortuosities. when a regular 0.35" J-wire is unable to cross the tortuous vessel, a PTCA 0.014" is used to cross this part. Then Balloon-Assisted Tracking '''(BAT)'''  can be useful. It is a technique in which a small compliant balloon usually 2.0mm X 15.0 or 20.0 mm  is inflated at the tip of the Guide-in catheter with half to one third of the balloon is inside the catheter. Balloon is inflated slightly over the nominal pressure and steered across the tortuous vessel over the PTCA wire.<ref name="pmid24826306">{{cite journal| author=Verouden NJ, Kiemeneij F| title=Balloon-Assisted Tracking to Overcome Radial Spasm during Transradial Coronary Angiography: A Case Report. | journal=Case Rep Cardiol | year= 2014 | volume= 2014 | issue=  | pages= 214310 | pmid=24826306 | doi=10.1155/2014/214310 | pmc=PMC4008174 | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=sumsearch.org/cite&retmode=ref&cmd=prlinks&id=24826306  }} </ref>


3- Guide catheter support and selection may be reduced.
3- Guide catheter support and selection may be reduced.

Revision as of 05:45, 24 August 2014

Radial artery catheterization Microchapters

Home

Patient Information

Overview

Radial Artery Anatomy

Advantages

Potential Pitfalls

Contraindications

Pre-procedure Assessment

Procedure

Achieving Hemostasis after Radial Artery Catheterization

Complications

Best Practices for Transradial Angiography (2013)

Case Studies

Case #1

Radial catheterization pitfalls On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Radial catheterization pitfalls

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Radial catheterization pitfalls

CDC onRadial catheterization pitfalls

Radial catheterization pitfalls in the news

Blogs on Radial catheterization pitfalls

Directions to Hospitals Treating Radial artery cathetarization

Risk calculators and risk factors for Radial catheterization pitfalls

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]

Overview

The data that had been published up till now entails an incidence of about 2% to 34% of radial artery spasm, which would result in transfemoral approach being used instead. [1]. So some precautions should be made beforehand in anticipation of such complications.

Potential Pitfalls of the Radial Approach to Cardiac Catheterization

1- Radial artery spasm:-

  • In order to decrease the incidence of radial artery spasm, some interventionist tend to give light sedation as well as intra-arterial Nitroglycerin and calcium channel blocker (verapamil or diltiazem) in order to relax the smooth muscles of the radial artery.

2- Vessel tortuosity. Some of the tortuous forms are:-

  • Alpha shape radial artery.
  • S-shaped radial artery.
  • Proximal and distal omega shaped radial artery.
  • Brachial alpha loop.
  • High origin radial artery.

A lot of techniques has been used to overcome tortuosities. when a regular 0.35" J-wire is unable to cross the tortuous vessel, a PTCA 0.014" is used to cross this part. Then Balloon-Assisted Tracking (BAT) can be useful. It is a technique in which a small compliant balloon usually 2.0mm X 15.0 or 20.0 mm is inflated at the tip of the Guide-in catheter with half to one third of the balloon is inside the catheter. Balloon is inflated slightly over the nominal pressure and steered across the tortuous vessel over the PTCA wire.[2]

3- Guide catheter support and selection may be reduced.

4- Loss of radial artery pulse in 4% of cases.

5- Potential increase in the duration of the procedure and fluroscopy time

6- The radial artery has been instrumented should there be a desire to use it as a conduit for CABG

7- It is the second and not the first approach learned by trainees

8- There is a learning curve in treating spasm, navigating anatomy, and manipulating catheters

9- Anatomically there can be a loop in the artery near the brachial in about 10% of cases

10- Smaller sheaths are required (4-8F)

References

  1. Lapras C, Bret P, Capdeville J (1978). "[Diastematomyelia. About a series of 6 cases (author's transl)]". Neurochirurgie. 24 (6): 381–9. PMID 752811.
  2. Verouden NJ, Kiemeneij F (2014). "Balloon-Assisted Tracking to Overcome Radial Spasm during Transradial Coronary Angiography: A Case Report". Case Rep Cardiol. 2014: 214310. doi:10.1155/2014/214310. PMC 4008174. PMID 24826306.


Template:WikiDoc Sources