Diaphragmatic paralysis diagnostic study of choice: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
{{Diaphragmatic paralysis}} | {{Diaphragmatic paralysis}} | ||
{{CMG}}; {{AE}}{{MA}} | {{CMG}}; {{AE}}{{MA}} [mailto:malihash@bidmc.harvard.edu] | ||
== Overview == | == Overview == | ||
Studies of choice for unilateral diaphragmatic paralysis include upright [[chest radiograph]] and fluoroscopic sniff test. Studies of choice for bilateral diaphragmatic paralysis include measurement of transdiaphragmatic pressure (Pdi). | Studies of choice for unilateral diaphragmatic paralysis include upright [[chest radiograph]] and fluoroscopic sniff test. Studies of choice for bilateral diaphragmatic paralysis include measurement of transdiaphragmatic pressure (Pdi). | ||
Line 7: | Line 7: | ||
== Diagnostic Study of Choice == | == Diagnostic Study of Choice == | ||
=== Unilateral diaphragmatic paralysis === | |||
* Upright [[chest radiograph]]: | * Upright [[chest radiograph]]: | ||
** Elevated hemidiaphragm in paralysed side<ref name="pmid15672847">{{cite journal |vauthors=Chetta A, Rehman AK, Moxham J, Carr DH, Polkey MI |title=Chest radiography cannot predict diaphragm function |journal=Respir Med |volume=99 |issue=1 |pages=39–44 |date=January 2005 |pmid=15672847 |doi= |url= |author=}}</ref><ref name="pmid96193042">{{cite journal |vauthors=Gierada DS, Slone RM, Fleishman MJ |title=Imaging evaluation of the diaphragm |journal=Chest Surg. Clin. N. Am. |volume=8 |issue=2 |pages=237–80 |date=May 1998 |pmid=9619304 |doi= |url= |author=}}</ref> | ** Elevated hemidiaphragm in paralysed side<ref name="pmid15672847">{{cite journal |vauthors=Chetta A, Rehman AK, Moxham J, Carr DH, Polkey MI |title=Chest radiography cannot predict diaphragm function |journal=Respir Med |volume=99 |issue=1 |pages=39–44 |date=January 2005 |pmid=15672847 |doi= |url= |author=}}</ref><ref name="pmid96193042">{{cite journal |vauthors=Gierada DS, Slone RM, Fleishman MJ |title=Imaging evaluation of the diaphragm |journal=Chest Surg. Clin. N. Am. |volume=8 |issue=2 |pages=237–80 |date=May 1998 |pmid=9619304 |doi= |url= |author=}}</ref> | ||
** [[Chest X-ray|Chest xray]] is then confirmed with fluoroscopic sniff test | ** [[Chest X-ray|Chest xray]] is then confirmed with fluoroscopic sniff test | ||
* Fluoroscopic sniff test: | * Fluoroscopic sniff test: | ||
** Observation of diaphragamtic movement when patient sniffs forcefully <ref name="pmid9619304">{{cite journal |vauthors=Gierada DS, Slone RM, Fleishman MJ |title=Imaging evaluation of the diaphragm |journal=Chest Surg. Clin. N. Am. |volume=8 |issue=2 |pages=237–80 |date=May 1998 |pmid=9619304 |doi= |url= |author=}}</ref> | ** Observation of diaphragamtic movement when patient sniffs forcefully<ref name="pmid9619304">{{cite journal |vauthors=Gierada DS, Slone RM, Fleishman MJ |title=Imaging evaluation of the diaphragm |journal=Chest Surg. Clin. N. Am. |volume=8 |issue=2 |pages=237–80 |date=May 1998 |pmid=9619304 |doi= |url= |author=}}</ref> | ||
** Paradoxical elevation of the paralyzed hemidiaphragm during [[inspiration]]<ref name="pmid4221861">{{cite journal |vauthors=Alexander C |title=Diaphragm movements and the diagnosis of diaphragmatic paralysis |journal=Clin Radiol |volume=17 |issue=1 |pages=79–83 |date=January 1966 |pmid=4221861 |doi= |url= |author=}}</ref> | ** Paradoxical elevation of the paralyzed hemidiaphragm during [[inspiration]]<ref name="pmid4221861">{{cite journal |vauthors=Alexander C |title=Diaphragm movements and the diagnosis of diaphragmatic paralysis |journal=Clin Radiol |volume=17 |issue=1 |pages=79–83 |date=January 1966 |pmid=4221861 |doi= |url= |author=}}</ref> | ||
=== Bilateral diaphragmatic paralysis === | |||
* Measurement of transdiaphragmatic pressure (Pdi) is the gold standard test for the diagnosis of bilateral diaphragmatic paralysis. | * Measurement of transdiaphragmatic pressure (Pdi) is the gold standard test for the diagnosis of bilateral diaphragmatic paralysis. | ||
** This test is performed with two catheters. One of them is placed in [[esophagus]] and it assesses changing [[pleural]] [[pressure]] (Ppl) and another one is placed in [[stomach]] and it detects changing [[gastric]] [[pressure]] (Pga). | ** This test is performed with two catheters. One of them is placed in [[esophagus]] and it assesses changing [[pleural]] [[pressure]] (Ppl) and another one is placed in [[stomach]] and it detects changing [[gastric]] [[pressure]] (Pga). |
Revision as of 15:28, 28 February 2018
Diaphragmatic Paralysis Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Diaphragmatic paralysis diagnostic study of choice On the Web |
American Roentgen Ray Society Images of Diaphragmatic paralysis diagnostic study of choice |
Diaphragmatic paralysis diagnostic study of choice in the news |
Risk calculators and risk factors for Diaphragmatic paralysis diagnostic study of choice |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Mahda Alihashemi M.D. [2] [3]
Overview
Studies of choice for unilateral diaphragmatic paralysis include upright chest radiograph and fluoroscopic sniff test. Studies of choice for bilateral diaphragmatic paralysis include measurement of transdiaphragmatic pressure (Pdi).
Diagnostic Study of Choice
Unilateral diaphragmatic paralysis
- Upright chest radiograph:
- Elevated hemidiaphragm in paralysed side[1][2]
- Chest xray is then confirmed with fluoroscopic sniff test
- Fluoroscopic sniff test:
- Observation of diaphragamtic movement when patient sniffs forcefully[3]
- Paradoxical elevation of the paralyzed hemidiaphragm during inspiration[4]
Bilateral diaphragmatic paralysis
- Measurement of transdiaphragmatic pressure (Pdi) is the gold standard test for the diagnosis of bilateral diaphragmatic paralysis.
- This test is performed with two catheters. One of them is placed in esophagus and it assesses changing pleural pressure (Ppl) and another one is placed in stomach and it detects changing gastric pressure (Pga).
- Pdi is the difference between Ppl and Pga (Pdi = Ppl – Pga).
- Normal transdiaphragmatic pressure:[5]
- Men: 148 cm water
- Women: 122 cm water
- The following result of transdiaphragmatic pressure (Pdi) is confirmatory of bilateral diaphragmatic paralysis:[6][7]
- Unilateral diaphragmatic paralysis:
- Bilateral diaphragmatic paralysis:
- Maximal transdiaphragmatic pressure is less than 40 cm water and it effects normal ventilatory behaviors.
References
- ↑ Chetta A, Rehman AK, Moxham J, Carr DH, Polkey MI (January 2005). "Chest radiography cannot predict diaphragm function". Respir Med. 99 (1): 39–44. PMID 15672847.
- ↑ Gierada DS, Slone RM, Fleishman MJ (May 1998). "Imaging evaluation of the diaphragm". Chest Surg. Clin. N. Am. 8 (2): 237–80. PMID 9619304.
- ↑ Gierada DS, Slone RM, Fleishman MJ (May 1998). "Imaging evaluation of the diaphragm". Chest Surg. Clin. N. Am. 8 (2): 237–80. PMID 9619304.
- ↑ Alexander C (January 1966). "Diaphragm movements and the diagnosis of diaphragmatic paralysis". Clin Radiol. 17 (1): 79–83. PMID 4221861.
- ↑ Miller JM, Moxham J, Green M (July 1985). "The maximal sniff in the assessment of diaphragm function in man". Clin. Sci. 69 (1): 91–6. PMID 4064560.
- ↑ Gill LC, Mantilla CB, Sieck GC (May 2015). "Impact of unilateral denervation on transdiaphragmatic pressure". Respir Physiol Neurobiol. 210: 14–21. doi:10.1016/j.resp.2015.01.013. PMC 4449269. PMID 25641347.
- ↑ McCool FD, Tzelepis GE (March 2012). "Dysfunction of the diaphragm". N. Engl. J. Med. 366 (10): 932–42. doi:10.1056/NEJMra1007236. PMID 22397655.