Patent foramen ovale MRI: Difference between revisions
Jump to navigation
Jump to search
Line 8: | Line 8: | ||
==MRI== | ==MRI== | ||
Contrast-enhanced MRI is not commonly used but may be helpful in the diagnosis of patent foramen ovale. The presence of an early contrast enhancement due to intracardiac right-to-left shunting in the left atrium before the contrast agent reaches the pulmonary veins is diagnostic of patent foramen ovale. | *Contrast-enhanced MRI is not commonly used but may be helpful in the diagnosis of patent foramen ovale. The presence of an early contrast enhancement due to intracardiac right-to-left shunting in the left atrium before the contrast agent reaches the pulmonary veins is diagnostic of patent foramen ovale.<ref name="MohrsPetersen2005">{{cite journal|last1=Mohrs|first1=Oliver K.|last2=Petersen|first2=Steffen E.|last3=Erkapic|first3=Damir|last4=Rubel|first4=Christine|last5=Schräder|first5=Rainer|last6=Nowak|first6=Bernd|last7=Fach|first7=W. Andreas|last8=Kauczor|first8=Hans-Ulrich|last9=Voigtlaender|first9=Thomas|title=Diagnosis of Patent Foramen Ovale Using Contrast-Enhanced Dynamic MRI: A Pilot Study|journal=American Journal of Roentgenology|volume=184|issue=1|year=2005|pages=234–240|issn=0361-803X|doi=10.2214/ajr.184.1.01840234}}</ref> | ||
*The grading of PFO using contast-enhanced MRI include:<ref name="MohrsPetersen2005">{{cite journal|last1=Mohrs|first1=Oliver K.|last2=Petersen|first2=Steffen E.|last3=Erkapic|first3=Damir|last4=Rubel|first4=Christine|last5=Schräder|first5=Rainer|last6=Nowak|first6=Bernd|last7=Fach|first7=W. Andreas|last8=Kauczor|first8=Hans-Ulrich|last9=Voigtlaender|first9=Thomas|title=Diagnosis of Patent Foramen Ovale Using Contrast-Enhanced Dynamic MRI: A Pilot Study|journal=American Journal of Roentgenology|volume=184|issue=1|year=2005|pages=234–240|issn=0361-803X|doi=10.2214/ajr.184.1.01840234}}</ref> | |||
:*Grade 0: No contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins. | |||
:*Grade 1: Only slight contrast enhancement close to the atrial septum without enhancement of the entire left atrium before the contrast agent reached the pulmonary veins. | |||
:*Grade 2: Only slight contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins; and grade 3, bright contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins. | |||
==References== | ==References== |
Revision as of 20:54, 27 February 2020
Patent Foramen Ovale Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Patent foramen ovale MRI On the Web |
American Roentgen Ray Society Images of Patent foramen ovale MRI |
Risk calculators and risk factors for Patent foramen ovale MRI |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editors-In-Chief: Priyamvada Singh, M.B.B.S. [2], Kristin Feeney, B.S. [3], Ifeoma Odukwe, M.D. [4]
Overview
There are no MRI findings associated with patent foramen ovale.
MRI
- Contrast-enhanced MRI is not commonly used but may be helpful in the diagnosis of patent foramen ovale. The presence of an early contrast enhancement due to intracardiac right-to-left shunting in the left atrium before the contrast agent reaches the pulmonary veins is diagnostic of patent foramen ovale.[1]
- The grading of PFO using contast-enhanced MRI include:[1]
- Grade 0: No contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins.
- Grade 1: Only slight contrast enhancement close to the atrial septum without enhancement of the entire left atrium before the contrast agent reached the pulmonary veins.
- Grade 2: Only slight contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins; and grade 3, bright contrast enhancement in the left atrium before the contrast agent reached the pulmonary veins.
References
- ↑ 1.0 1.1 Mohrs, Oliver K.; Petersen, Steffen E.; Erkapic, Damir; Rubel, Christine; Schräder, Rainer; Nowak, Bernd; Fach, W. Andreas; Kauczor, Hans-Ulrich; Voigtlaender, Thomas (2005). "Diagnosis of Patent Foramen Ovale Using Contrast-Enhanced Dynamic MRI: A Pilot Study". American Journal of Roentgenology. 184 (1): 234–240. doi:10.2214/ajr.184.1.01840234. ISSN 0361-803X.