==Component of robotic repair== | |||
* | *Surgeon console | ||
** | *Computerized control system | ||
* | *Two instrument arms | ||
*Fiberoptic camera. | |||
==Advantage== | |||
* Operation could be performed by the surgeons from remote distance. | |||
* Excellent visualization and magnification of internal anatomy due to the two-camera systems. | |||
* Better precision compared to hand done surgery | |||
* High degree of freedom of movement | |||
* Performance of complex operations with great success | |||
* Less traumatic for patient | |||
* Less pain so less use of pain medications | |||
* Small incisions | |||
* Minimal scarring | |||
* Shorter hospital stay (usually 3 to 4 days) | |||
* Decreased bleeding | |||
* Decreased infection | |||
* Shorter recovery period | |||
* No restrictions in activities | |||
==Principles of Robotic surgery== | |||
Due to this technique a surgeon can perform operations from a remote distance. The surgeon gets an excellent three dimensional view of | Due to this technique a surgeon can perform operations from a remote distance. The surgeon gets an excellent three dimensional view of | ||
the heart through the fiberoptic stereoscopic camera. The surgeon's hand motions are relayed to a computer processor, which digitizes and relays them to the fine instrument tips placed into the chest cavity through small 1 cm port incisions. First, the computer interface permits the accurate translation of the surgeon's hand motions to a dexterous endoscopic "wrist" placed within the chest cavity. | the heart through the fiberoptic stereoscopic camera. The surgeon's hand motions are relayed to a computer processor, which digitizes and relays them to the fine instrument tips placed into the chest cavity through small 1 cm port incisions. First, the computer interface permits the accurate translation of the surgeon's hand motions to a dexterous endoscopic "wrist" placed within the chest cavity. |
Revision as of 02:10, 10 September 2011
Atrial Septal Defect Microchapters | |
Treatment | |
---|---|
Surgery | |
| |
Special Scenarios | |
Case Studies | |
Atrial septal defect robotic repair On the Web | |
American Roentgen Ray Society Images of Atrial septal defect robotic repair | |
Risk calculators and risk factors for Atrial septal defect robotic repair | |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editors-In-Chief: Priyamvada Singh, MBBS [2]; Cafer Zorkun, M.D., Ph.D. [3]; Assistant Editor-In-Chief: Kristin Feeney, B.S. [4]
Overview
Robotic repair is the most recent and advanced approach for the repair of atrial septal defect
Component of robotic repair
- Surgeon console
- Computerized control system
- Two instrument arms
- Fiberoptic camera.
Advantage
- Operation could be performed by the surgeons from remote distance.
- Excellent visualization and magnification of internal anatomy due to the two-camera systems.
- Better precision compared to hand done surgery
- High degree of freedom of movement
- Performance of complex operations with great success
- Less traumatic for patient
- Less pain so less use of pain medications
- Small incisions
- Minimal scarring
- Shorter hospital stay (usually 3 to 4 days)
- Decreased bleeding
- Decreased infection
- Shorter recovery period
- No restrictions in activities
Principles of Robotic surgery
Due to this technique a surgeon can perform operations from a remote distance. The surgeon gets an excellent three dimensional view of the heart through the fiberoptic stereoscopic camera. The surgeon's hand motions are relayed to a computer processor, which digitizes and relays them to the fine instrument tips placed into the chest cavity through small 1 cm port incisions. First, the computer interface permits the accurate translation of the surgeon's hand motions to a dexterous endoscopic "wrist" placed within the chest cavity.