Pulmonary embolism landmark trials: Difference between revisions
Jump to navigation
Jump to search
Line 16: | Line 16: | ||
* '''Comparison with PIOPED:''' In contrast to the original PIOPED study, which used contrast pulmonary angiography as the primary reference test for PE, PIOPED II used composite reference test for venous thromboembolism that was based on the ventilation/perfusion lung scan, venous compression ultrasound of the lower extremities, digital subtraction pulmonary angiography, and contrast venography in various combinations to establish the PE status of the patient. New criteria for ventilation/perfusion lung scan diagnosis were developed for PIOPED II. | * '''Comparison with PIOPED:''' In contrast to the original PIOPED study, which used contrast pulmonary angiography as the primary reference test for PE, PIOPED II used composite reference test for venous thromboembolism that was based on the ventilation/perfusion lung scan, venous compression ultrasound of the lower extremities, digital subtraction pulmonary angiography, and contrast venography in various combinations to establish the PE status of the patient. New criteria for ventilation/perfusion lung scan diagnosis were developed for PIOPED II. | ||
3. '''PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III)''' | 3. '''PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III)''' (2010). <ref name="pmid20368649">{{cite journal |author=Stein PD, Chenevert TL, Fowler SE, Goodman LR, Gottschalk A, Hales CA, Hull RD, Jablonski KA, Leeper KV, Naidich DP, Sak DJ, Sostman HD, Tapson VF, Weg JG, Woodard PK|title=Gadolinium-enhanced magnetic resonance angiography for pulmonary embolism: a multicenter prospective study (PIOPED III)|journal=Ann. Intern. Med. |volume=152 |issue=7 |pages=434–43, W142–3 |year=2010 |month=April |pmid=20368649 |pmc=3138428|doi=10.1059/0003-4819-152-7-201004060-00008 |url= |accessdate=2012-01-10}}</ref> | ||
* '''Purpose :'''The purpose of this study is to determine the diagnostic accuracy of gadolinium-enhanced magnetic resonance angiography (Gd-MRA) of the pulmonary arteries in combination with magnetic resonance venography (MRV) of the veins of the thighs in patients with clinically suspected acute pulmonary embolism (PE).''' | * '''Purpose :'''The purpose of this study is to determine the diagnostic accuracy of gadolinium-enhanced magnetic resonance angiography (Gd-MRA) of the pulmonary arteries in combination with magnetic resonance venography (MRV) of the veins of the thighs in patients with clinically suspected acute pulmonary embolism (PE).''' | ||
*'''Study Type:''' Observational | *'''Study Type:''' Observational |
Revision as of 16:16, 10 January 2012
Pulmonary Embolism Microchapters |
Diagnosis |
---|
Pulmonary Embolism Assessment of Probability of Subsequent VTE and Risk Scores |
Treatment |
Follow-Up |
Special Scenario |
Trials |
Case Studies |
Pulmonary embolism landmark trials On the Web |
Directions to Hospitals Treating Pulmonary embolism landmark trials |
Risk calculators and risk factors for Pulmonary embolism landmark trials |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-In-Chief: Ujjwal Rastogi, MBBS [2]
Landmark Clinical Trials
Trials assessing the diagnosis
1. PIOPED (Prospective Investigation in Pulmonary Embolism Diagnosis) (1989).[1]
- Purpose : To evaluate the sensitivity and specificity of two major, widely used technologies, radionuclear imaging (ventilation-perfusion scanning) and pulmonary angiography, for the diagnosis of pulmonary embolism.
- Study Type: Interventional
- Study Design: Primary Purpose: Diagnostic
2. PIOPED II (Prospective Investigation in Pulmonary Embolism Diagnosis II) (2002).[2]
- Purpose : It was designed to assess the efficacy of the spiral computed tomographic pulmonary angiogram in patients suspected of having acute pulmonary embolism (PE).
- Study Type: Interventional
- Study Design: Primary Purpose: Diagnostic
- Comparison with PIOPED: In contrast to the original PIOPED study, which used contrast pulmonary angiography as the primary reference test for PE, PIOPED II used composite reference test for venous thromboembolism that was based on the ventilation/perfusion lung scan, venous compression ultrasound of the lower extremities, digital subtraction pulmonary angiography, and contrast venography in various combinations to establish the PE status of the patient. New criteria for ventilation/perfusion lung scan diagnosis were developed for PIOPED II.
3. PIOPED III (Prospective Investigation of Pulmonary Embolism Diagnosis III) (2010). [3]
- Purpose :The purpose of this study is to determine the diagnostic accuracy of gadolinium-enhanced magnetic resonance angiography (Gd-MRA) of the pulmonary arteries in combination with magnetic resonance venography (MRV) of the veins of the thighs in patients with clinically suspected acute pulmonary embolism (PE).
- Study Type: Observational
- Study Design:
- Observational Model: Cohort
- Time Perspective: Prospective
References
- ↑ "Value of the ventilation/perfusion scan in acute pulmonary embolism. Results of the prospective investigation of pulmonary embolism diagnosis (PIOPED). The PIOPED Investigators". JAMA. 263 (20): 2753–9. 1990. PMID 2332918.
|access-date=
requires|url=
(help) - ↑ Gottschalk A, Stein PD, Goodman LR, Sostman HD (2002). "Overview of Prospective Investigation of Pulmonary Embolism Diagnosis II". Semin Nucl Med. 32 (3): 173–82. doi:10.1053/snuc.2002.124177. PMID 12105798. Retrieved 2012-01-10. Unknown parameter
|month=
ignored (help) - ↑ Stein PD, Chenevert TL, Fowler SE, Goodman LR, Gottschalk A, Hales CA, Hull RD, Jablonski KA, Leeper KV, Naidich DP, Sak DJ, Sostman HD, Tapson VF, Weg JG, Woodard PK (2010). "Gadolinium-enhanced magnetic resonance angiography for pulmonary embolism: a multicenter prospective study (PIOPED III)". Ann. Intern. Med. 152 (7): 434–43, W142–3. doi:10.1059/0003-4819-152-7-201004060-00008. PMC 3138428. PMID 20368649. Unknown parameter
|month=
ignored (help);|access-date=
requires|url=
(help)