Anion gap: Difference between revisions
No edit summary |
m Bot: Automated text replacement (-{{SIB}} + & -{{EH}} + & -{{EJ}} + & -{{Editor Help}} + & -{{Editor Join}} +) |
||
Line 2: | Line 2: | ||
{{CMG}} | {{CMG}} | ||
== Overview == | == Overview == | ||
Line 137: | Line 137: | ||
{{Intensive care medicine}} | {{Intensive care medicine}} | ||
{{Renal physiology}} | {{Renal physiology}} | ||
[[Category:Electrolyte disturbance]] | [[Category:Electrolyte disturbance]] | ||
[[Category:Intensive care medicine]] | [[Category:Intensive care medicine]] |
Revision as of 22:13, 8 August 2012
WikiDoc Resources for Anion gap |
Articles |
---|
Most recent articles on Anion gap |
Media |
Evidence Based Medicine |
Clinical Trials |
Ongoing Trials on Anion gap at Clinical Trials.gov Clinical Trials on Anion gap at Google
|
Guidelines / Policies / Govt |
US National Guidelines Clearinghouse on Anion gap
|
Books |
News |
Commentary |
Definitions |
Patient Resources / Community |
Patient resources on Anion gap Discussion groups on Anion gap Directions to Hospitals Treating Anion gap Risk calculators and risk factors for Anion gap
|
Healthcare Provider Resources |
Causes & Risk Factors for Anion gap |
Continuing Medical Education (CME) |
International |
|
Business |
Experimental / Informatics |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [2]
Overview
- The anion gap is used to aid in the differential diagnosis of metabolic acidosis; (The cause of metabolic acidosis is determined by the anion gap).
- Chloride and bicarbonate comprise 85% of the anions in the serum
- The remaining anions are called the anion gap
- Reference range: 8-16 mmol/l
Uses
The anion gap is representative of the unmeasured anions in the plasma, and these anions are affected differently based on the type of metabolic acidosis. The primary function of the anion gap measurement is to allow a clinician to narrow down the possible causes of a patient's metabolic acidosis. For example, if a patient presents with metabolic acidosis, but a normal anion gap, then conditions that cause a high anion gap can be ruled out as being the cause of the acidosis.
Interpretation and causes
Anion gap can be classified as either high, normal or, in rare cases, low. A high anion gap indicates that there is loss of HCO3- without a subsequent increase in Cl-. Electroneutrality is maintained by the increased production of anions like ketones, lactate, PO4-, and SO4-; these anions are not part of the anion-gap calculation and therefore a high anion gap results. In patients with a normal anion gap the drop in HCO3- is compensated for by an increase in Cl- and hence is also known as hyperchloremic acidosis.
Complete Differential Diagnosis of the Causes of Anion gap
(by gap classification}
Low anion gap
A low anion gap is relatively rare but may occur from the presence of abnormal positively charged proteins, as in multiple myeloma, or in the setting of a low serum albumin level.
- Bromism [1]
- Dilution
- Hypercalcemia
- Hypermagnesemia
- Hypernatremia
- Hyperviscosity
- Hypoalbuminemia
- Increased unmeasured cations
- Lithium toxicity
- Multiple Myeloma
- Paraproteinemia
- Pheochromocytoma
- Underestimation of serum sodium
Normal anion gap (hyperchloremic acidosis)
Usually the HCO3- lost is replaced by a chloride anion, and thus there is a normal anion gap.
- Alcohol (such as ethanol) can effect anion gap by inducing alcohol dehydrogenase enzyme.
- Ammonium chloride and Acetazolamide
- Arginine and lysine during total parenteral nutrition
- Carbonic anhydrase inhibitors
- Drugs
- Enteral bicarbonate loss: diarrhea (note: vomiting causes hypochloraemic alkalosis)
- Fluid loss with pancreatitis
- Ileal stoma
- Pancreatic fistula
- Recovery from diabetic ketoacidosis
- Renal loss of HCO3- (i.e. proximal renal tubular acidosis)
- Renal dysfunction (i.e. renal failure, hypoaldosteronism, distal renal tubular acidosis)
- Some cases of ketoacidosis, particularly during insulin treatment
- Ureteroenterostomy
High anion gap
The bicarbonate lost is replaced by an unmeasured anion and thus you will see a high anion gap.
- Hyperosmolar hyperglycemic nonketotic coma
- Lactic acidosis
- Ketoacidosis
- Renal failure (acute/chronic)
- Toxins or drugs:
- Ethanol
- Ethylene glycol
- Lactic acid
- Methanol
- Paraldehyde
- Aspirin
- Cyanide, coupled with elevated venous oxygenation
- Iron
- isoniazid
The mnemonic "MUDPILES" is used to remember the causes of a high anion gap.
M - methanol/metformin
U - uremia
D - diabetic ketoacidosis
P - paraldehyde/propylene glycol
I - Infection/ischemia/isoniazid
L - lactate
E - ethylene glycol/ethanol
S - salicylates/starvation
Some people, especially those not in the emergency room, find the mnemonic KIL-U easier to remember and also more useful clinically:
K - Ketones
I - Ingestion
L - lactic acid
U - uremia
All of the components of "mudpiles" are also covered with the "KIL-U" device, with the bonus that these are things that can kill you.
Ketones: more straightforward than remembering diabetic ketosis and starvation ketosis, etc.
Ingestion: methanol, metformin, paraldehyde, propylene glycol, isoniazid, ethylene glycol, ethanol, and salicilates are covered by ingestion. These can be thought of as a single group: "ingestions" during the initial consideration, especially when not triaging a patient in the emergency room.
Lactate: including that caused by infection and shock
Calculation
It is calculated by subtracting the serum concentrations of chloride and bicarbonate (anions) from the concentrations of sodium plus potassium (cations):
Anion Gap = ( [Na+]+[K+] ) - ( [Cl-]+[HCO3-] )
However, for daily practice, the potassium is frequently ignored, leaving the following equation:
Anion Gap = ( [Na+] ) - ( [Cl-]+[HCO3-] )
Normal value ranges
In the past, methods for the measurement of the anion gap consisted of colorimetry for [HCO3-] and [Cl-] as well as flame photometry for [Na+] and [K+]. Thus normal reference values ranged from 8 to 16 mmol/L plasma when not including [K+] and from 10 to 20 mmol/L plasma when including [K+]. Some specific sources use 15[2] and 8-16 mEq/L.[3][4]
Modern analysers make use of ion-selective electrodes which give a normal anion gap as <11 mmol/L. Therefore according to the new classification system a high anion gap is anything above 11mmol/L and a normal anion gap is between 3-11 mmol/L.[5]
References
- ↑ Sailer, Christian, Wasner, Susanne. Differential Diagnosis Pocket. Hermosa Beach, CA: Borm Bruckmeir Publishing LLC, 2002:34 ISBN 1591032016
- ↑ Essentials of Human Physiology by Thomas M. Nosek. Section 7/7ch12/7ch12p51.
- ↑ http://physioweb.med.uvm.edu/bodyfluids/theanion.htm
- ↑ http://fitsweb.uchc.edu/student/selectives/TimurGraham/Anion_Gap.html
- ↑ [1] The Fall Of The Serum Anion Gap.