TIMI myocardial perfusion grade 0: Difference between revisions
Jump to navigation
Jump to search
Rim Halaby (talk | contribs) |
|||
Line 20: | Line 20: | ||
[[File:TMPG-0-case-01.gif]] | [[File:TMPG-0-case-01.gif]] | ||
[[TIMI myocardial perfusion grade 0 case studies|Other examples of TMPG 0]] | |||
[[Category:Angiographic Definitions]] | [[Category:Angiographic Definitions]] |
Revision as of 21:18, 24 August 2013
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Overview
Failure of dye to enter the microvasculature, indicating a lack of tissue level perfusion.
- Intensity Range: 0
- 0.5 = Minimal ground glass appearance (“blush”) or opacification of the myocardium in the distribution of the artery. Minimal blush is being defined as being either very small in size and/or being less intense or bright than “normal” blush.
- Intensity Range: 0.5
- Note - If no blush is present, the Qualitative Blush Analysis will all be “DNA=Does Not Apply” except for “Total Frames Elapsed in which Blush is Present” which would be “0”, “Total frames in Cinerun” and the venous system assessments.
Example
Shown below are a static image and an animated image depicting TIMI myocardial perfusion grade 0.