Inverted P wave: Difference between revisions
No edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
== Overview== | == Overview== | ||
Ordinarily, an impulse traveling from a point high in the atrium to the ventricle is right side up on the electrocardiographic tracing, but if this pacemaker impulse originates in lower part of the atrium, the orientation of the electrical vector may cause it to appear upside down or to be an "inverted P-wave". | Ordinarily, an impulse traveling from a point high in the atrium to the ventricle is right side up on the electrocardiographic tracing, but if this pacemaker impulse originates in lower part of the atrium, the orientation of the electrical vector may cause it to appear upside down or to be an "inverted P-wave". | ||
==Pathophysiology== | |||
===Retrograde Atrial Activation=== | |||
This occurs when there is a ventriculoatrial conduction of electrical impulse through the [[AV node]]. The origin of the electrical impulses could either be from: | |||
* Ectopic foci in the atrium - This could be a single or multiple foci in the atrium. Foci within the atrium usually originate below the [[crista terminalis]] in the right atrium for it to have a significant effect on the [[p wave]]. | |||
* AV node - This results into the various [[junctional rhythms]] e.g. [[AVNRT]], [[AVRT]]. | |||
* Ventricles - This results into ventricular tachycardias or rhythm. | |||
==Causes== | |||
* [[Dextrocardia]] | |||
* Lead switch or misplacement | |||
* Causes of retrograde atrial activation | |||
==References== | ==References== |
Revision as of 19:28, 30 August 2013
WikiDoc Resources for Inverted P wave |
Articles |
---|
Most recent articles on Inverted P wave Most cited articles on Inverted P wave |
Media |
Powerpoint slides on Inverted P wave |
Evidence Based Medicine |
Clinical Trials |
Ongoing Trials on Inverted P wave at Clinical Trials.gov Trial results on Inverted P wave Clinical Trials on Inverted P wave at Google
|
Guidelines / Policies / Govt |
US National Guidelines Clearinghouse on Inverted P wave NICE Guidance on Inverted P wave
|
Books |
News |
Commentary |
Definitions |
Patient Resources / Community |
Patient resources on Inverted P wave Discussion groups on Inverted P wave Patient Handouts on Inverted P wave Directions to Hospitals Treating Inverted P wave Risk calculators and risk factors for Inverted P wave
|
Healthcare Provider Resources |
Causes & Risk Factors for Inverted P wave |
Continuing Medical Education (CME) |
International |
|
Business |
Experimental / Informatics |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Overview
Ordinarily, an impulse traveling from a point high in the atrium to the ventricle is right side up on the electrocardiographic tracing, but if this pacemaker impulse originates in lower part of the atrium, the orientation of the electrical vector may cause it to appear upside down or to be an "inverted P-wave".
Pathophysiology
Retrograde Atrial Activation
This occurs when there is a ventriculoatrial conduction of electrical impulse through the AV node. The origin of the electrical impulses could either be from:
- Ectopic foci in the atrium - This could be a single or multiple foci in the atrium. Foci within the atrium usually originate below the crista terminalis in the right atrium for it to have a significant effect on the p wave.
- AV node - This results into the various junctional rhythms e.g. AVNRT, AVRT.
- Ventricles - This results into ventricular tachycardias or rhythm.
Causes
- Dextrocardia
- Lead switch or misplacement
- Causes of retrograde atrial activation