Atrial septal defect contrast echocardiography
Atrial Septal Defect Microchapters | |
Treatment | |
---|---|
Surgery | |
| |
Special Scenarios | |
Case Studies | |
Atrial septal defect contrast echocardiography On the Web | |
American Roentgen Ray Society Images of Atrial septal defect contrast echocardiography | |
Risk calculators and risk factors for Atrial septal defect contrast echocardiography | |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-In-Chief: Priyamvada Singh, M.B.B.S. [2], Cafer Zorkun, M.D., Ph.D. [3]; Assistant Editor(s)-In-Chief: Kristin Feeney, B.S. [4]
For a full discussion on the usage of echocardiography for atrial septal defect diagnosis click here.
Overview
Echocardiography is the preferred diagnostic tool in the evaluation of an atrial septal defect. Contrast echocardiography is an effective modality that can be performed in individuals with a suspected atrial septal defect which is not visualized definitively on transthoracic imaging.
Contrast echocardiography
- Used to determine the presence of intercardiac shunting often seen in the apical four chamber view
- Agitated saline is commonly used as the contrast material.
- Saline contrast can visualize heart function, problems in the left ventricle, and problems in the surrounding valves.
- Injected into a peripheral vein during echocardiography, small air bubbles can be seen on the imaging.
- It may be possible to see bubbles travel across an atrial septal defect either at rest or during a cough.
- Bubbles will only flow from right atrium to left atrium if the RA pressure is greater than LA
Common Findings
- A right-to-left interatrial shunt can be seen:
- When an atrial septal defect with accompanying pulmonary hypertension, resulting in a left-to-right reversal.
- Any time a patent foramen ovale defect is present.
- When an uncomplicated atrial septal defect has an imbalance in right-sided pressure, such as from coughing or the Valsalva maneuver.
- When an uncomplicated atrial septal defect has a momentary onset of left ventricular contraction.
Sensitivity
- Not recommended for:
- Left-to-right interatrial shunt diagnosis
- Pregnant patients
- Patients with severe pulmonary hypertension
Disadvantages
- False positives in the setting of a pulmonary arteriovenous malformation
- Difficulty in quantifying the size of the shunt