Mechanical ventilation protocol

Jump to navigation Jump to search

Mechanical ventilation Microchapters

Home

Patient Information

Overview

Historical Perspective

Types of Ventilators

Indications for Use

Ventilator variables

Choosing Amongst Ventilator Modes

Initial Ventilator Settings

Protocol

Complications

Modification of Settings

Connection to Ventilators

Terminology

Mechanical ventilation protocol On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Mechanical ventilation protocol

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Mechanical ventilation protocol

CDC on Mechanical ventilation protocol

Mechanical ventilation protocol in the news

Blogs on Mechanical ventilation protocol

Directions to Hospitals Treating Mechanical ventilation

Risk calculators and risk factors for Mechanical ventilation protocol

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1] Associate Editor(s)-in-Chief: Vishnu Vardhan Serla M.B.B.S. [2]

Mechanical Ventilation Protocol

Inclusion Criteria

Ventilator Setup

  • Calculate predicted body weight. It is calculated using the formula
Males = 50 + 2.3[height(in inches)-60]
Females = 45.5 + 2.3[height(in inches)-60]
  • Selecting the ventilator mode
  • Set ventilator settings to achieve initial Vt = 8 ml/kg of predicted body weight
  • Reduce VT by 1 ml/kg at intervals ≤ 2 hours until VT = 6ml/kg PBW.
  • Set initial rate to approximate baseline minute ventilation (not > 35 breaths per minute).
  • Adjust VT and respiratory rate to achieve pH and plateau pressure goals below.

Oxygenation Goal

  • PaO2 55-80 mmHg or SpO2 88-95% is the goal.
  • Use a minimum PEEP of 5 cm H2O.
  • Consider use of incremental FiO2/PEEP combinations to achieve goal.
Lower PEEP/Higher FiO2
FiO2 0.3 0.4 0.4 0.5 0.5 0.6 0.7 0.7 0.7 0.8 0.9 0.9 0.9 1.0
PEEP 5 5 8 8 10 10 10 12 14 14 14 16 18 18-24
Higher PEEP/Lower FiO2
FiO2 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.5 - 0.8 0.8 0.9 1.0 1.0
PEEP 5 8 10 12 14 14 16 16 18 20 22 22 22 24

Plateau Pressure Goal

  • Plateau pressure goal(Pplat) is <= 30 cm H2O
  • Check Pplat every 4th hourly after change in PEEP ot VT
  • If Pplat > 30 cm of H2O
Decrease VT by 1ml/kg
  • If Pplat < 25 cm of H2O and VT < 6ml/kg
Increase VT by 1ml/kg unbtil Pplat > 25 cm H2O or VT = 6 ml/kg
  • If Pplat < 30 cm and breath stacking or dys-synchrony occurs
Increase VT in 1 ml/kg increments to 7 or 8 ml/kg, if Pplat remains <=30 cm of H2O

PH Goal

  • pH should be maintained at 7.30 - 7.45
  • If pH is less than 7.30 (acidosis)

a. Range of 7.15 - 7.30

Increase respiratory rate until pH > 7.30 or PaCO2
Maximum rate can be 35

b. Less than 7.15

Increase respiratory rate to 35
VT can be increased in 1 ml/kg until pH >7.15 (Pplat target of 30 may be exceeded)
Bicarbonate can be given
Decrease the ventilation rate if possible

I:E Ratio Goal

Recommend that duration of inspiration be less than equal to duration of expiration.

Weaning

A spontaneous breathing trial has to be done daily when

  • FiO2 ≤ 0.40 and PEEP ≤ 8.
  • PEEP and FiO2 ≤ values of previous day.
  • Patient has acceptable spontaneous breathing efforts. (May decrease vent rate by 50% for 5 minutes to detect effort.)
  • Systolic BP ≥ 90 mm Hg without vasopressor support.
  • No neuromuscular blocking agents or blockade.

Spontaneous Breathing Trial

If all above criteria are met and patient has been in the observed for at least 12 hours, initiate a trial of upto 120 minutes of spontaneous breathing with FiO2 < 0.5 and PEEP < 5

1. Place on T-piece, trach collar, or CPAP ≤ 5 cm H2O with PS < 5

2. Assess for tolerance as below for up to two hours.

a. SpO2 ≥ 90: and/or PaO2 ≥ 60 mm Hg b. Spontaneous VT ≥ 4 ml/kg predicted body weight c. RR ≤ 35/min d. pH ≥ 7.3 e. No respiratory distress (distress= 2 or more)

HR > 120% of baseline
Marked accessory muscle use
Abdominal paradox
Diaphoresis
Marked dyspnea

3. If tolerated for at least 30 minutes, consider extubation.

4. If not tolerated resume pre-weaning settings.

References