Radial catheterization procedure

Revision as of 15:44, 29 November 2013 by Ayokunle Olubaniyi (talk | contribs)
Jump to navigation Jump to search

Radial artery cathetarization Microchapters

Home

Patient Information

Overview

Radial Artery Anatomy

Advantages

Potential Pitfalls

Contraindications

Pre-procedure Assessment

Procedure

Achieving Hemostasis after Radial Artery Catheterization

Complications

Best Practices for Transradial Angiography

Case Studies

Case #1

Radial catheterization procedure On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

slides

Images

American Roentgen Ray Society Images of Radial catheterization procedure

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Radial catheterization procedure

CDC onRadial catheterization procedure

Radial catheterization procedure in the news

Blogs on Radial catheterization procedure

Directions to Hospitals Treating Radial artery cathetarization

Risk calculators and risk factors for Radial catheterization procedure

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor-In-Chief: Varun Kumar, M.B.B.S.; Lakshmi Gopalakrishnan, M.B.B.S.

Overview

Catheter selection

Many operators choose to start with the right coronary artery as the right sided catheter may allow for directing the wire as you make your way up around the arch. Once the wire is around the arch, it should remain there for exchanges. A JL 3.5 catheter may be used to engage the left coronary artery when catheterization is performed from the right arm.

Procedure

  1. The wrist should be shaved (if necessary) and cleansed in the usual sterile fashion. In addition, the groin should be prepped in case of access failure or the need for urgent IABP or a temporary venous pacemaker
  2. Intravenous (IV) line should be started on the contralateral extremity. If an IV should be placed in the intervention extremity, it must be placed proximal to wrist preferably at the level of elbow.
  3. Arm is abducted and the wrist hyperextended
  4. Local skin anesthesia is then administered
  5. Proximal to styloid process of the radius, a small incision is made over the skin
  6. Subcutaneous tissue is then tunneled using forceps
  7. At 45° angle, an 18-21 guage needle should be introduced and an exchange length 0.035-0.038 inch J-tip guidewire is inserted
  8. Radial sheath of 23cm long and 4-6Fr size should then be introduced
  9. Using a rotating arm board under the shoulder facilitates ease of movement and placement of radial sheath
  10. Through sidearm of the sheath, 5000U of heparin should be administered
  11. To reduce spasm, 500 micrograms of diltiazem can also be administered via the sidearm
  12. Coronary catheters are then advanced along the guidewire into aorta
  13. Left and right coronary arteries are then catheterized using Judkins, Amplatz or multipurpose catheter
  14. Hemostasis is achieved by direct pressure at the puncture site at the end of the procedure after removal of radial sheath
  15. Radial pulse should be monitored after the procedure for several hours regularly.

Radial sheath kits are now available which contain hydrophilic coated sheaths in sizes 4-6Fr equipped with graduated introducers, various micropuncture needles and guidewire.