White coat hypertension
White coat hypertension | |
DiseasesDB | 14138 |
---|
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Overview
White coat hypertension is a phenomenon in which patients exhibit elevated blood pressure in a clinical setting but not when recorded by themselves at home. It is believed that this is due to the anxiety some people experience during a clinic visit.
As the notion of "normal" is subjective and changes from individual to individual a reference measurement was necessary. As night-time and self measured values are often not subject to daily stress and clinical values are subject to unusual anxiety, daytime ambulatory blood pressure is used as a reference as it takes into account daily stress but not in excess. Due to specificity involved in diagnosis of white coat hypertension, many problems have been incurred in its diagnosis and treatment.
Diagnosis
The diagnosis of white coat hypertension is made difficult as a result of the unreliable measures taken from the conventional methods of detection. These methods often involve an interface with health care professionals and frequently results are tarnished by a list of factors including variability in the individual’s blood pressure, technical inaccuracies, anxiety of the patient, recent ingestion of pressor substances and talking, amongst many other factors. The most common measure of blood pressure is taken from a non invasive instrument called a sphygmomanometer. "A survey showed that 96% of primary care physicians habitually use a cuff size too small," (Thomas G Pickering, 1994) adding to the difficulty in making an informed diagnosis. For such reasons, white coat hypertension can not be diagnosed with a standard clinical visit.
Patients of white coat hypertension do not exhibit the signs indicative of trepidation and their increased blood pressure is often not accompanied with tachycardia (TG Pickering 1988). This is supported by studies that repeatedly indicate that 15–30% of those thought to have mild hypertension as a result of clinic or office recordings, display normal blood pressure and no unusual response to pressure stimulus. These persons did not show any specific characteristics such as age that may be indicative of a higher susceptibility to white coat hypertension (BP McGrath, 1996).
Ambulatory monitoring and patient self-measurement using a home blood pressure monitoring device is being increasingly used to differentiate those with white-coat hypertension or experiencing the white coat effect from those with chronic hypertension. This does not mean that these methods are without fault. Day time ambulatory values, despite taking into account stresses of everyday life when taken during the patient’s daily routine, is still susceptible to the effects of daily variables such as physical activity, stress and duration of sleep. Ambulatory monitoring has been found to be the more practical and reliable method in detecting patients with white coat hypertension and for the prediction of target organ damage. Even as such, the diagnosis and treatment of white coat hypertension remains controversial.
Recent studies (American Journal of Hypertension, May 2006) showed home blood pressure monitoring is as accurate as a 24 hour ambulatory monitoring in determining blood pressure levels. Researchers at the University of Turku, Finland studied 98 patients with untreated hypertension. They compared patients using a home blood pressure device and those wearing a 24hr ambulatory monitor. Researcher Dr. Niiranen said that, "home blood pressure measurement can be used effectively for guiding anti-hypertensive treatment". Dr. Stergiou added that home tracking of blood pressure, "is more convenient and also less costly than ambulatory monitoring".
Implications for treatment
It should be remembered that all the established published trials on the consequences of high blood pressure and the benefits of treating, are based on one-time measurement in clinical settings rather than the generally slightly lower readings obtained from ambulatory recordings.
The debate and conflicting ideas revolve around whether or not it would be feasible to treat white coat hypertension as there still is no conclusive evidence that a temporary rising in blood pressure during clinic visits has an adverse effect on health. It has been proposed that in order to facilitate treatment decisions.
In fact many cross sectional studies have shown that "target-organ damage (as exemplified by left ventricular hypertrophy) is less in white-coat hypertensive [patients] than in sustained hypertensive [patients] even after the allowance has been made for differences in clinic pressure"(TG Pickering, 1994). Many believe that patients with "white coat" hypertension do not require even very small doses of antihypertensive therapy as it may result in hypotension but must still be careful as patients may show signs of vascular changes and may eventually develop hypertension.
If a typically normotensive patient has high blood pressure during an anxiety provoking experience, such as being reviewed by a health care professional, they are said to be experiencing the white coat effect.
See also
References
- Donald E. Hricik, Jackson T. Wright, Michael C. Smith. Hypertension secrets. c2002; 9-10, 83,88
- Norman M. Kaplan, Ellin Lieberman. Clinical hypertension. Seventh edition. 1998; 23-26, 31-32, 35, 142
- Pickering T (1994). "Blood pressure measurement and detection of hypertension". Lancet. 344 (8914): 31–5. PMID 7912303.
- Ramsay L, Williams B, Johnston G, MacGregor G, Poston L, Potter J, Poulter N, Russell G (1999). "British Hypertension Society guidelines for hypertension management 1999: summary". BMJ. 319 (7210): 630–5. PMID 10473485.
- Pickering T, James G, Boddie C, Harshfield G, Blank S, Laragh J (1988). "How common is white coat hypertension?". JAMA. 259 (2): 225–8. PMID 3336140.
- Pierdomenico S, Mezzetti A, Lapenna D, Guglielmi M, Mancini M, Salvatore L, Antidormi T, Costantini F, Cuccurullo F (1995). "'White-coat' hypertension in patients with newly diagnosed hypertension: evaluation of prevalence by ambulatory monitoring and impact on cost of health care". Eur Heart J. 16 (5): 692–7. PMID 7588903.
- McGrath B (1996). "Is white-coat hypertension innocent?". Lancet. 348 (9028): 630. PMID 8782749. - commenatry on:
Glen S, Elliott H, Curzio J, Lees K, Reid J (1996). "White-coat hypertension as a cause of cardiovascular dysfunction". Lancet. 348 (9028): 654–7. PMID 8782756. - Gosse P, Promax H, Durandet P, Clementy J (1993). "'White coat' hypertension. No harm for the heart". Hypertension. 22 (5): 766–70. PMID 8225536.