Glucagon
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Deepika Beereddy, MBBS [2]
Disclaimer
WikiDoc MAKES NO GUARANTEE OF VALIDITY. WikiDoc is not a professional health care provider, nor is it a suitable replacement for a licensed healthcare provider. WikiDoc is intended to be an educational tool, not a tool for any form of healthcare delivery. The educational content on WikiDoc drug pages is based upon the FDA package insert, National Library of Medicine content and practice guidelines / consensus statements. WikiDoc does not promote the administration of any medication or device that is not consistent with its labeling. Please read our full disclaimer here.
Overview
Glucagon is a gastrointestinal agent that is FDA approved for the treatment of severe hypoglycemia, and as a diagnostic acid. Common adverse reactions include nausea and vomiting, temporary increase in blood pressure and pulse may occur after administration.
Adult Indications and Dosage
FDA-Labeled Indications and Dosage (Adult)
Hypoglycemia (Severe)
- Dosing Information
- Using the supplied prefilled syringe, carefully insert the needle through the rubber stopper of the vial containing GlucaGen powder and inject all the liquid from the syringe into the vial.
- Shake the vial gently until the powder is completely dissolved and no particles remain in the fluid. The reconstituted fluid should be clear and of water-like consistency.
- The reconstituted GlucaGen gives a concentration of approximately 1 mg/mL glucagon.
- The reconstituted GlucaGen should be used immediately after reconstitution.
- Inject 1 mL (adults , weighing more than 55 lbs (25 kg)) subcutaneously, intramuscularly, or intravenously.
- Discard any unused portion.
- Emergency assistance should be sought immediately after subcutaneous or intramuscular injection of glucagon.
- The glucagon injection may be repeated using a new kit while waiting for emergency assistance.
- Intravenous glucose MUST be administered if the patient fails to respond to glucagon.
- When the patient has responded to the treatment, give oral carbohydrates to restore the liver glycogen and prevent recurrence of hypoglycemia.
Radiography of gastrointestinal tract
- Dosing Information
- GlucaGen should be reconstituted with 1 mL of Sterile Water for Reconstitution (if supplied) or 1 mL of Sterile Water for Injection, USP. Using a syringe, withdraw all of the Sterile Water for Reconstitution (if supplied) or 1 mL Sterile Water for Injection, USP and inject into the GlucaGen vial.
- Shake the vial gently until the powder is completely dissolved and no particles remain in the fluid. The reconstituted fluid should be clear and of water-like consistency.
- The reconstituted GlucaGen gives a concentration of approximately 1 mg/mL glucagon.
- The reconstituted GlucaGen should be used immediately after reconstitution.
- GlucaGen must be administered by medical personnel.
- Discard any unused portion.
- Onset of action after an injection will depend on the organ under examination and route of administration.
- The usual diagnostic dose for relaxation of the stomach, duodenal bulb, duodenum, and small bowel is 0.2 mg to 0.5 mg given intravenously or 1 mg given intramuscularly; the usual dose to relax the colon is 0.5 mg to 0.75 mg intravenously and 1 mg to 2 mg intramuscularly.
- After the end of the diagnostic procedure, give oral carbohydrates to patients who have been fasting, if this is compatible with the diagnostic procedure applied.
- The GlucaGen Diagnostic Kit and the GlucaGen 10-pack presentations are intended only for use by healthcare providers as a diagnostic aid. The GlucaGen Diagnostic Kit and the GlucaGen 10-pack presentations are not intended for use by patients to treat severe hypoglycemia because they are not packaged with a syringe and diluent necessary for rapid preparation and administration during an emergency outside of a healthcare facility.
Dosage forms and strengths
- GlucaGen is supplied in a vial, alone, or accompanied by Sterile Water for Reconstitution (1 mL) also in a vial (10 pack or diagnostic kit). It is also supplied as GlucaGen HypoKit®, a presentation with a disposable prefilled syringe containing 1 mL Sterile Water for Reconstitution. When the glucagon powder is reconstituted with Sterile Water for Reconstitution (if supplied) or with Sterile Water for Injection, USP, it forms a solution of 1 mg/mL (1 unit/mL) glucagon for subcutaneous, intramuscular, or intravenous injection.
Off-Label Use and Dosage (Adult)
Guideline-Supported Use
- There is limited information regarding Off-Label Guideline-Supported Use of Glucagon in adult patients.
Non–Guideline-Supported Use
- There is limited information regarding Off-Label Non–Guideline-Supported Use of Glucagon in adult patients.
Pediatric Indications and Dosage
FDA-Labeled Indications and Dosage (Pediatric)
Hypoglycemia (Severe)
- Dosing Information
- Using the supplied prefilled syringe, carefully insert the needle through the rubber stopper of the vial containing GlucaGen powder and inject all the liquid from the syringe into the vial.
- Shake the vial gently until the powder is completely dissolved and no particles remain in the fluid. The reconstituted fluid should be clear and of water-like consistency.
- The reconstituted GlucaGen gives a concentration of approximately 1 mg/mL glucagon.
- The reconstituted GlucaGen should be used immediately after reconstitution.
- Inject 1 mL (children, weighing more than 55 lbs (25 kg)) or 0.5 mL (children weighing less than 55 lbs (25 kg)) subcutaneously, intramuscularly, or intravenously. If the weight is not known: children younger than 6 years should be given a 0.5 mL and children 6 years and older should be given 1 mL.
- Discard any unused portion.
- Emergency assistance should be sought immediately after subcutaneous or intramuscular injection of glucagon.
- The glucagon injection may be repeated using a new kit while waiting for emergency assistance.
- Intravenous glucose MUST be administered if the patient fails to respond to glucagon.
- When the patient has responded to the treatment, give oral carbohydrates to restore the liver glycogen and prevent recurrence of hypoglycemia.
Off-Label Use and Dosage (Pediatric)
Guideline-Supported Use
There is limited information regarding Off-Label Guideline-Supported Use of Glucagon in pediatric patients.
Non–Guideline-Supported Use
There is limited information regarding Off-Label Non–Guideline-Supported Use of Glucagon in pediatric patients.
Contraindications
- GlucaGen is contraindicated in patients with:
- Known hypersensitivity to glucagon, lactose or any other constituent in GlucaGen
- Pheochromocytoma
- Insulinoma
Warnings
Pheochromocytoma
- Glucagon is contraindicated in patients with pheochromocytoma because Glucagon may stimulate the release of catecholamines from the tumor. If the patient develops a dramatic increase in blood pressure, 5 to 10 mg of phentolamine mesylate has been shown to be effective in lowering blood pressure for the short time that control would be needed.
Insulinoma and Glucagonoma
- GlucaGen should be administered cautiously to patients suspected of having insulinoma or glucagonoma. In patients with insulinoma, intravenous administration of glucagon may produce an initial increase in blood glucose; however, glucagon administration may directly or indirectly (through an initial rise in blood glucose) stimulate exaggerated insulin release from an insulinoma. A patient developing symptoms of hypoglycemia after a dose of glucagon should be given glucose orally or intravenously, whichever is most appropriate. Caution should also be observed in administering GlucaGen to patients with glucagonoma.
Hypersensitivity and Allergic Reactions
- Allergic reactions may occur and include generalized rash, and in some cases anaphylactic shock with breathing difficulties, and hypotension. The anaphylactic reactions have generally occurred in association with endoscopic examination during which patients often received other agents including contrast media and local anesthetics. The patients should be given standard treatment for anaphylaxis including an injection of epinephrine if they encounter respiratory difficulties after GlucaGen injection.
Glycogen Stores and Hypoglycemia
- In order for GlucaGen treatment to reverse hypoglycemia, adequate amounts of glucose must be stored in the liver (as glycogen). Therefore, GlucaGen should be used with caution in patients with conditions such as prolonged fasting, starvation, adrenal insufficiency or chronic hypoglycemia because these conditions result in low levels of releasable glucose in the liver and an inadequate reversal of hypoglycemia by GlucaGen treatment.
Cardiac Disease
- Caution should be observed when glucagon is used as an adjunct in endoscopic or radiographic procedures to inhibit gastrointestinal motility in patients with known cardiac disease.
Laboratory Tests
- Blood glucose measurements may be considered to monitor the patient’s response.
Adverse Reactions
Clinical Trials Experience
- Side effects may include nausea and vomiting at doses above 1 mg or with rapid injection. *Hypotension has been reported up to 2 hours after administration in patients receiving GlucaGen as premedication for upper GI endoscopy procedures. Glucagon exerts positive inotropic and chronotropic effects and may, therefore, cause tachycardia and hypertension. Adverse reactions indicating toxicity of GlucaGen have not been reported. A temporary increase in both blood pressure and pulse rate may occur following the administration of glucagon. Patients taking beta-blockers might be expected to have a greater increase in both pulse and blood pressure, an increase of which will be temporary because of glucagon’s short half-life. The increase in blood pressure and pulse rate may require therapy in patients with pheochromocytoma or coronary artery disease. Anaphylactic reactions may occur in some cases.
- The following adverse reactions have been identified during postapproval use of GlucaGen. Because these adverse reactions are reported voluntarily from a population of uncertain size, it is generally not possible to reliably estimate their frequency.
Postmarketing Experience
There is limited information regarding Glucagon Postmarketing Experience in the drug label.
Drug Interactions
Beta-blockers
- Patients taking beta-blockers might be expected to have a greater increase in both pulse and blood pressure, an increase of which will be temporary because of glucagon’s short half-life. The increase in blood pressure and pulse rate may require therapy in patients with pheochromocytoma or coronary artery disease.
Indomethacin
- When used with indomethacin, glucagon may lose its ability to raise blood glucose or may even produce hypoglycemia. Therefore, caution should be exercised for patients taking indomethacin when glucagon will be administered.
Anticholinergic Drugs
- Coadministration with an anticholinergic drug is not recommended due to increased gastrointestinal side effects.
Warfarin
- Glucagon may increase the anticoagulant effect of warfarin. Therefore, caution should be exercised for patients taking warfarin when glucagon will be administered.
Insulin
- Insulin reacts antagonistically towards glucagon. Therefore, caution should be exercised when glucagon is used as a diagnostic aid in diabetes patients.
Use in Specific Populations
Pregnancy
- Pregnancy Category B. Reproduction studies were performed in rats and rabbits at GlucaGen doses of 0.4, 2.0, and 10 mg/kg. These doses represent exposures of up to 100 and 200 times the human dose based on mg/m2 for rats and rabbits, respectively, and revealed no evidence of harm to the fetus. There are, however, no adequate and well-controlled studies in pregnant women. Glucagon does not cross the human placenta barrier.
- Australian Drug Evaluation Committee (ADEC) Pregnancy Category
There is no Australian Drug Evaluation Committee (ADEC) guidance on usage of Glucagon in women who are pregnant.
Labor and Delivery
- There is no FDA guidance on use of Glucagon during labor and delivery.
Nursing Mothers
- It is not known whether this drug is excreted in human milk. Because many drugs are excreted in human milk, caution should be exercised when GlucaGen is administered to a nursing woman. No clinical studies have been performed in nursing mothers, however, GlucaGen is a peptide and intact glucagon is not absorbed from the GI tract. Therefore, even if the infant ingested glucagon it would be unlikely to have any effect on the infant. Additionally, GlucaGen has a short plasma half-life thus limiting amounts available to the child. Glucagon does not cross the human placental barrier.
Pediatric Use
- For the treatment of severe hypoglycemia: The use of glucagon in pediatric patients has been reported to be safe and effective.
- For use as a diagnostic aid: Safety and effectiveness in pediatric patients have not been established.
Geriatic Use
- There is no FDA guidance on the use of Glucagon with respect to geriatric patients.
Gender
- There is no FDA guidance on the use of Glucagon with respect to specific gender populations.
Race
- There is no FDA guidance on the use of Glucagon with respect to specific racial populations.
Renal Impairment
- There is no FDA guidance on the use of Glucagon in patients with renal impairment.
Hepatic Impairment
- There is no FDA guidance on the use of Glucagon in patients with hepatic impairment.
Females of Reproductive Potential and Males
- There is no FDA guidance on the use of Glucagon in women of reproductive potentials and males.
Immunocompromised Patients
- There is no FDA guidance one the use of Glucagon in patients who are immunocompromised.
Administration and Monitoring
Administration
- For GlucaGenHypoKit:
Treatment of severe hypoglycemia
- Using the supplied prefilled syringe, carefully insert the needle through the rubber stopper of the vial containing GlucaGen powder and inject all the liquid from the syringe into the vial.
- Shake the vial gently until the powder is completely dissolved and no particles remain in the fluid. The reconstituted fluid should be clear and of water-like consistency.
- The reconstituted GlucaGen gives a concentration of approximately 1 mg/mL glucagon.
- The reconstituted GlucaGen should be used immediately after reconstitution.
- Inject 1 mL (adults and children, weighing more than 55 lbs (25 kg)) or 0.5 mL (children weighing less than 55 lbs (25 kg)) subcutaneously, intramuscularly, or intravenously. If the weight is not known: children younger than 6 years should be given a 0.5 mL and children 6 years and older should be given 1 mL.
- Discard any unused portion.
- Emergency assistance should be sought immediately after subcutaneous or intramuscular injection of glucagon.
- The glucagon injection may be repeated using a new kit while waiting for emergency assistance.
- Intravenous glucose MUST be administered if the patient fails to respond to glucagon.
- When the patient has responded to the treatment, give oral carbohydrates to restore the liver glycogen and prevent recurrence of hypoglycemia.
- For GlucaGen Diagnostic Kit and the GlucaGen 10-pack:
Use as a diagnostic aid
- GlucaGen should be reconstituted with 1 mL of Sterile Water for Reconstitution (if supplied) or 1 mL of Sterile Water for Injection, USP. Using a syringe, withdraw all of the Sterile Water for Reconstitution (if supplied) or 1 mL Sterile Water for Injection, USP and inject into the GlucaGen vial.
- Shake the vial gently until the powder is completely dissolved and no particles remain in the fluid. The reconstituted fluid should be clear and of water-like consistency.
- The reconstituted GlucaGen gives a concentration of approximately 1 mg/mL glucagon.
- The reconstituted GlucaGen should be used immediately after reconstitution.
- GlucaGen must be administered by medical personnel.
- Discard any unused portion.
- Onset of action after an injection will depend on the organ under examination and route of administration.
- The usual diagnostic dose for relaxation of the stomach, duodenal bulb, duodenum, and small bowel is 0.2 mg to 0.5 mg given intravenously or 1 mg given intramuscularly; the usual dose to relax the colon is 0.5 mg to 0.75 mg intravenously and 1 mg to 2 mg intramuscularly.
- After the end of the diagnostic procedure, give oral carbohydrates to patients who have been fasting, if this is compatible with the diagnostic procedure applied.
- The GlucaGen Diagnostic Kit and the GlucaGen 10-pack presentations are intended only for use by healthcare providers as a diagnostic aid. The GlucaGen Diagnostic Kit and the GlucaGen 10-pack presentations are not intended for use by patients to treat severe hypoglycemia because they are not packaged with a syringe and diluent necessary for rapid preparation and administration during an emergency outside of a healthcare facility.
Dosage forms and strengths
- GlucaGen is supplied in a vial, alone, or accompanied by Sterile Water for Reconstitution (1 mL) also in a vial (10 pack or diagnostic kit). It is also supplied as GlucaGen HypoKit®, a presentation with a disposable prefilled syringe containing 1 mL Sterile Water for Reconstitution. When the glucagon powder is reconstituted with Sterile Water for Reconstitution (if supplied) or with Sterile Water for Injection, USP, it forms a solution of 1 mg/mL (1 unit/mL) glucagon for subcutaneous, intramuscular, or intravenous injection.
Monitoring
- Blood glucose measurements may be considered to monitor the patient’s response.
IV Compatibility
- There is limited information regarding IV Compatibility of Glucagon in the drug label.
Overdosage
- No reports of overdosage with GlucaGen have been reported. If overdosage occurs, the patient may experience nausea, vomiting, inhibition of GI tract motility, increase in blood pressure and pulse rate. In case of suspected overdosing, the serum potassium may decrease and should be monitored and corrected if needed. If the patient develops a dramatic increase in blood pressure, phentolamine mesylate has been shown to be effective in lowering blood pressure for the short time that control would be needed.
Pharmacology
Mechanism of Action
- Antihypoglycemic Action: Glucagon induces liver glycogen breakdown, releasing glucose from the liver. Hepatic stores of glycogen are necessary for glucagon to produce an antihypoglycemic effect.
- Gastrointestinal Motility Inhibition: Extra hepatic effects of glucagon include relaxation of the smooth muscle of the stomach, duodenum, small bowel, and colon.
Structure
- GlucaGen (glucagon [rDNA origin] for injection) is an antihypoglycemic agent and a gastrointestinal motility inhibitor. It is produced by expression of recombinant DNA in a Saccharomyces cerevisiae vector with subsequent purification. The chemical structure of the glucagon in GlucaGen is identical to human glucagon and to glucagon extracted from beef and pork pancreas. Glucagon with the empirical formula of C153H225N43O49S, and a molecular weight of 3483, is a single-chain polypeptide containing 29 amino acid residues. The structure of glucagon is:
- GlucaGen is a sterile, lyophilized white powder in a 2 mL vial. The reconstituted solution contains glucagon as hydrochloride 1 mg/mL (1 unit/mL) and lactose monohydrate (107 mg). GlucaGen is supplied at pH 2.5-3.5 and is soluble in water.
Pharmacodynamics
For the treatment of severe hypoglycemia:
- Blood glucose concentration rises within 10 minutes of injection and maximal concentrations are attained at approximately 30 minutes after injection (see Figure 1). The duration of hyperglycemic action after intravenous or intramuscular injection is 60 – 90 minutes.
Pharmacokinetics
- Intramuscular injection of 1 mg GlucaGen resulted in a mean Cmax (CV%) of 1686 pg/mL (43%) and median Tmax of 12.5 minutes. The mean apparent half-life of 45 minutes after intramuscular injection probably reflects prolonged absorption from the injection site. Glucagon is degraded in the liver, kidney, and plasma.
Nonclinical Toxicology
Carcinogenesis, Mutagenesis, Impairment of Fertility
- Long term studies in animals to evaluate carcinogenic potential have not been performed. Several studies have been conducted to evaluate the mutagenic potential of glucagon. The mutagenic potential tested in the Ames and human lymphocyte assays, was borderline positive under certain conditions for both glucagon (pancreatic) and glucagon (rDNA) origin. In vivo, very high doses (100 and 200 mg/kg) of glucagon (both origins) gave a slightly higher incidence of micronucleus formation in male mice but there was no effect in females. The weight of evidence indicates that GlucaGen is not different from glucagon pancreatic origin and does not pose a genotoxic risk to humans. GlucaGen (rDNA origin) was not tested in animal fertility studies. Studies in rats have shown that pancreatic glucagon does not cause impaired fertility.
Clinical Studies
- There is limited information regarding Clinical Studies of Glucagon in the drug label.
How Supplied
- GlucaGen is supplied as a sterile, lyophilized white powder in a vial, alone, or accompanied by Sterile Water for Reconstitution also in a vial (Diagnostic Kit or 10-pack). It is also supplied as GlucaGen HypoKit with a disposable prefilled syringe containing Sterile Water for Reconstitution.
- GlucaGenHypoKit includes:
- 1 vial containing 1 mg (1 unit) GlucaGen (glucagon [rDNA origin] for injection)
- 1 disposable syringe containing 1 mL Sterile Water for Reconstitution
- NDC 0169-7065-15
- GlucaGen Diagnostic Kit includes:
- 1 vial containing 1 mg (1 unit) GlucaGen (glucagon [rDNA origin] for injection)
- 1 vial containing 1 mL Sterile Water for Reconstitution
- NDC 55390-004-01
- GlucaGenHypoKit (Two-Pack) includes: 2 packs of GlucaGen HypoKit,
- Each HypoKit contains:
- 1 vial containing 1 mg (1 unit) GlucaGen (glucagon [rDNA origin] for injection)
- 1 disposable syringe containing 1 mL Sterile Water for Reconstitution
- NDC 0169-7065-21
- The GlucaGen 10-pack includes:
- 10 vials, each containing 1 mg (1 unit) GlucaGen (glucagon [rDNA origin] for injection)
- NDC 55390-004-10
Storage
Before Reconstitution:
- The GlucaGen package may be stored up to 24 months at controlled room temperature 20o to 25o C (68o to 77o F) prior to reconstitution. Do not freeze. Keep in the original package to protect from light. GlucaGen should not be used after the expiry date on the vials.
After Reconstitution:
- Reconstituted GlucaGen should be used immediately. Discard any unused portion. If the solution shows any sign of gel formation or particles, it should be discarded.
Images
Drug Images
{{#ask: Page Name::Glucagon |?Pill Name |?Drug Name |?Pill Ingred |?Pill Imprint |?Pill Dosage |?Pill Color |?Pill Shape |?Pill Size (mm) |?Pill Scoring |?NDC |?Drug Author |format=template |template=DrugPageImages |mainlabel=- |sort=Pill Name }}
Package and Label Display Panel
{{#ask: Label Page::Glucagon |?Label Name |format=template |template=DrugLabelImages |mainlabel=- |sort=Label Page }}
Patient Counseling Information
- [See FDA-Approved Patient Labeling (Patient Instructions for Emergency Use).]
Physician Instructions
- Refer patients and family members to the FDA-approved patient labeling for instructions describing the method of preparing and injecting GlucaGen. Advise the patient and family members to become familiar with the technique of preparing glucagon before an emergency arises. Instruct patients to use 1 mg for adults or ½ the adult dose (0.5 mg) for children weighing less than 55 lb (25 kg). To prevent severe hypoglycemia, patients and family members should be informed of the symptoms of mild hypoglycemia and how to treat it appropriately. Family members should be informed to arouse the patient as quickly as possible because prolonged hypoglycemia may result in damage to the central nervous system. Patients should be advised to inform their physician when hypoglycemic reactions occur so that the treatment regimen may be adjusted if necessary.
- No studies on the effects on the ability to drive and use machines have been performed. After diagnostic procedures, hypoglycemia has been reported infrequently. The patient’s ability to concentrate and react may be impaired as a result of hypoglycemia. This may present a risk in situations where these abilities are especially important, such as driving or operating machinery. Therefore, these activities should be avoided until the patient has had a meal with oral carbohydrates.
Precautions with Alcohol
- Alcohol-Glucagon interaction has not been established. Talk to your doctor about the effects of taking alcohol with this medication.
Brand Names
Glucagen, Glucagen Diagnostic Kit, Glucagon, Glucagon Diagnostic Kit, Glucagon Emergency Kit.
Look-Alike Drug Names
- A® — B®[1]
Drug Shortage Status
Price
References
The contents of this FDA label are provided by the National Library of Medicine.