Atrial septal defect contrast echocardiography

Revision as of 18:57, 2 September 2011 by Kristin Feeney (talk | contribs)
Jump to navigation Jump to search

Atrial Septal Defect Microchapters

Home

Patient Information

Overview

Anatomy

Classification

Ostium Secundum Atrial Septal Defect
Ostium Primum Atrial Septal Defect
Sinus Venosus Atrial Septal Defect
Coronary Sinus
Patent Foramen Ovale
Common or Single Atrium

Pathophysiology

Epidemiology and Demographics

Risk Factors

Natural History and Prognosis

Complications

Diagnosis

History and Symptoms

Physical Examination

Electrocardiogram

Chest X Ray

CT

MRI

Echocardiography

Transesophageal Echocardiography
Transthoracic Echocardiography
Contrast Echocardiography
M-Mode
Doppler

Transcranial Doppler Ultrasound

Cardiac Catheterization

Exercise Testing

ACC/AHA Guidelines for Evaluation of Unoperated Patients

Treatment

Medical Therapy

Surgery

Indications for Surgical Repair
Surgical Closure
Minimally Invasive Repair


Robotic ASD Repair
Percutaneous Closure
Post-Surgical Follow Up

Special Scenarios

Pregnancy
Diving and Decompression Sickness
Paradoxical Emboli
Pulmonary Hypertension
Eisenmenger's Syndrome
Atmospheric Pressure

Case Studies

Case #1

Atrial septal defect contrast echocardiography On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Atrial septal defect contrast echocardiography

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Atrial septal defect contrast echocardiography

CDC on Atrial septal defect contrast echocardiography

Atrial septal defect contrast echocardiography in the news

Blogs on Atrial septal defect contrast echocardiography

Directions to Hospitals Treating Type page name here

Risk calculators and risk factors for Atrial septal defect contrast echocardiography

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-In-Chief: Priyamvada Singh, M.B.B.S. [2], Cafer Zorkun, M.D., Ph.D. [3]; Assistant Editor(s)-In-Chief: Kristin Feeney, B.S. [4]

For a full discussion on the usage of echocardiography for atrial septal defect diagnosis click here.

Overview

Echocardiography is the preferred diagnostic tool in the evaluation of an atrial septal defect. Contrast echocardiography is an effective modality that can be performed in individuals with a suspected atrial septal defect which is not visualized definitively on transthoracic imaging.

Contrast echocardiography

  • Used to determine the presence of intercardiac shunting often seen in the apical four chamber view
  • Agitated saline is commonly used as the contrast material.
  • Saline contrast can visualize heart function, problems in the left ventricle, and problems in the surrounding valves.
  • Injected into a peripheral vein during echocardiography, small air bubbles can be seen on the imaging.
  • It may be possible to see bubbles travel across an atrial septal defect either at rest or during a cough.
  • Bubbles will only flow from right atrium to left atrium if the RA pressure is greater than LA

Common Findings

  • A right-to-left interatrial shunt can be seen:
  • When an atrial septal defect with accompanying pulmonary hypertension, resulting in a left-to-right reversal.
  • Any time a patent foramen ovale defect is present.
  • When an uncomplicated atrial septal defect has an imbalance in right-sided pressure, such as from coughing or the Valsalva maneuver.
  • When an uncomplicated atrial septal defect has a momentary onset of left ventricular contraction.

Sensitivity

  • Not recommended for:
  • Left-to-right interatrial shunt diagnosis
  • Pregnant patients
  • Patients with severe pulmonary hypertension

Disadvantages

  • False positives in the setting of a pulmonary arteriovenous malformation
  • Difficulty in quantifying the size of the shunt

ACC / AHA Guidelines - Evaluation of the Unoperated Patient (DO NOT EDIT)[1]

Class I

1) ASD should be diagnosed by imaging techniques with demonstration of shunting across the defect and evidence of RV volume overload and any associated anomalies. (Level of Evidence: C)

2) Patients with unexplained RV volume overload should be referred to an ACHD center for further diagnostic studies to rule out obscure ASD, partial anomalous venous connection, or coronary sinoseptal defect. (Level of Evidence: C)



References

  1. Warnes CA, Williams RG, Bashore TM, Child JS, Connolly HM, Dearani JA; et al. (2008). "ACC/AHA 2008 guidelines for the management of adults with congenital heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Develop Guidelines on the Management of Adults With Congenital Heart Disease). Developed in Collaboration With the American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons". J Am Coll Cardiol. 52 (23): e1–121. doi:10.1016/j.jacc.2008.10.001. PMID 19038677.