Cryostat

Jump to navigation Jump to search

WikiDoc Resources for Cryostat

Articles

Most recent articles on Cryostat

Most cited articles on Cryostat

Review articles on Cryostat

Articles on Cryostat in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on Cryostat

Images of Cryostat

Photos of Cryostat

Podcasts & MP3s on Cryostat

Videos on Cryostat

Evidence Based Medicine

Cochrane Collaboration on Cryostat

Bandolier on Cryostat

TRIP on Cryostat

Clinical Trials

Ongoing Trials on Cryostat at Clinical Trials.gov

Trial results on Cryostat

Clinical Trials on Cryostat at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on Cryostat

NICE Guidance on Cryostat

NHS PRODIGY Guidance

FDA on Cryostat

CDC on Cryostat

Books

Books on Cryostat

News

Cryostat in the news

Be alerted to news on Cryostat

News trends on Cryostat

Commentary

Blogs on Cryostat

Definitions

Definitions of Cryostat

Patient Resources / Community

Patient resources on Cryostat

Discussion groups on Cryostat

Patient Handouts on Cryostat

Directions to Hospitals Treating Cryostat

Risk calculators and risk factors for Cryostat

Healthcare Provider Resources

Symptoms of Cryostat

Causes & Risk Factors for Cryostat

Diagnostic studies for Cryostat

Treatment of Cryostat

Continuing Medical Education (CME)

CME Programs on Cryostat

International

Cryostat en Espanol

Cryostat en Francais

Business

Cryostat in the Marketplace

Patents on Cryostat

Experimental / Informatics

List of terms related to Cryostat


A Cryostat (cryo=cold and stat=stable) is a vessel, similar in construction to a vacuum flask, or Dewar used to maintain cold cryogenic temperatures.

Cryostat types

Magnetic Resonance Imaging and Research magnet types

Cryostats used in MRI machines are designed to hold a cryogen, typically helium, in a liquid state with minimal evaporation (boil-off). The liquid helium bath is designed to keep the superconducting magnet's bobbin of superconductive wire in its superconductive state. In this state the wire has no electrical resistance and very large currents are maintained with a low power input. To maintain superconductivity, the bobbin must be kept below its transition temperature by being immersed in the liquid helium. If, for any reason, the wire becomes resistive, i.e. loses superconductivity, a condition known as a "quench", the liquid helium evaporates, instantly raising pressure within the vessel. A burst disk, usually made of carbon, is placed within the chimney or vent pipe so that during a pressure excursion, the gaseous helium can be safely vented out of the MRI suite. Modern MRI cryostats use a mechanical refrigerator (cryocooler) to re-condense the helium gas and return it to the bath, to maintain cryogenic conditions and to conserve helium.

Typically cryostats are manufactured with two vessels, one inside the other. The outer vessel is evacuated with the vacuum acting as a thermal insulator. The inner vessel contains the cryogen and is supported within the outer vessel by structures made from low-conductivity materials. An intermediate shield between the outer and inner vessels intercepts the heat radiated from the outer vessel. This heat is removed by a cryocooler. Older helium cryostats used a liquid nitrogen vessel as this radiation shield and had the liquid helium in an inner, third, vessel. Nowadays few units using multiple cryogens are made with the trend being towards 'cryogen-free' cryostats in which all heat loads are removed by cryocoolers.

Biological microtome type

File:Cryostat microtome.jpg
Cryostat-microtome

In biology, cryostats are used for freezing specimens for sectioning and staining for microscopical examination. The cryostat-microtome is a type of Microtome where the device is located completely within a refrigerated chamber with glass window to enable viewing during the sectioning. To minimize unnecessary warming all necessary mechanical movements of the microtome can be achieved by hand via a wheel mounted outside the chamber. Specimens that are soft at room temperature need to be frozen before sectioning (for example at -20 degrees C).