Hemophilia echocardiography or ultrasound: Difference between revisions
(Created page with "__NOTOC__ {{Hemophilia}} Please help WikiDoc by adding content here. It's easy! Click here to learn about editing. ==References== {{Reflist|...") |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
{{Hemophilia}} | {{Hemophilia}} | ||
{{CMG}};{{AE}} {{Sab}} | |||
==Overview== | |||
There are no [[echocardiography]] findings associated with hemophilia. [[Ultrasound]] may be helpful in the [[diagnosis]] and follow-up of [[Hemophilia|hemophilic]] [[arthropathy]] and in [[Diagnosis|diagnosing]] massive [[Abdomen|intraabdominal]] [[Bleeding|bleeds]]. Findings on an [[ultrasound]] suggestive of [[Hemophilia|hemophilic]] [[arthropathy]] inlcude [[Soft tissue|soft-tissue]] changes, [[Bone|osteo]]-[[Cartilage|chondral]] changes, [[joint]] effusion, [[synovial]] [[Hypertrophy (medical)|hypertrophy]], [[hemosiderin]], and [[Bone|osteo]]-[[Cartilage|chondral]] abnormalities. | |||
==Echocardiography/Ultrasound== | |||
===Echocardiography=== | |||
There are no [[echocardiography]] findings associated with hemophilia. | |||
===Ultrasound=== | |||
*[[Ultrasound]] may be helpful in the [[diagnosis]] and follow-up of [[Hemophilia|hemophilic]] [[arthropathy]] and in [[Diagnosis|diagnosing]] massive [[Abdomen|intraabdominal]] [[Bleeding|bleeds]] | |||
*[[Ultrasound]] is highly reliable for assessing [[Soft tissue|soft-tissue]] changes with an intraclass correlation coefficient (ICC) for specific [[Joint|joints]] given below: | |||
:*0.98 for [[Ankle|ankles]]<ref name="pmid25714320">{{cite journal |vauthors=Doria AS, Keshava SN, Mohanta A, Jarrin J, Blanchette V, Srivastava A, Moineddin R, Kavitha ML, Hilliard P, Poonnoose P, Gibikote S |title=Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation |journal=AJR Am J Roentgenol |volume=204 |issue=3 |pages=W336–47 |date=March 2015 |pmid=25714320 |doi=10.2214/AJR.14.12501 |url=}}</ref> | |||
:*0.97 for [[Knee|knees]] | |||
*[[Ultrasound]] is substantially to highly reliable for assessing [[Bone|osteo]]-[[Cartilage|chondral]] changes with an intraclass correlation coefficient (ICC) for specific [[Joint|joints]] given below: | |||
:*0.61 for [[Ankle|ankles]]<ref name="pmid25714320">{{cite journal |vauthors=Doria AS, Keshava SN, Mohanta A, Jarrin J, Blanchette V, Srivastava A, Moineddin R, Kavitha ML, Hilliard P, Poonnoose P, Gibikote S |title=Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation |journal=AJR Am J Roentgenol |volume=204 |issue=3 |pages=W336–47 |date=March 2015 |pmid=25714320 |doi=10.2214/AJR.14.12501 |url=}}</ref> | |||
:*0.89 for [[Knee|knees]] | |||
*It is highly [[Sensitivity (tests)|sensitive]] (> 92%) for assessing [[synovial]] [[Hypertrophy (medical)|hypertrophy]] and [[hemosiderin]] in both [[Ankle|ankles]] and [[Knee|knees]]<ref name="pmid25714320">{{cite journal |vauthors=Doria AS, Keshava SN, Mohanta A, Jarrin J, Blanchette V, Srivastava A, Moineddin R, Kavitha ML, Hilliard P, Poonnoose P, Gibikote S |title=Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation |journal=AJR Am J Roentgenol |volume=204 |issue=3 |pages=W336–47 |date=March 2015 |pmid=25714320 |doi=10.2214/AJR.14.12501 |url=}}</ref> | |||
*It has borderline [[Sensitivity (tests)|sensitivity]] for detecting small amounts of [[fluid]] in [[Ankle|ankles]] (70%) in contrast to [[Knee|knees]] (93%) | |||
*It has variable [[Sensitivity (tests)|sensitivity]] for evaluating [[Bone|osteo]]-[[Cartilage|chondral]] abnormalities (86-100% for [[Ankle|ankles]] and 12-100% for [[Knee|knees]]) | |||
==References== | ==References== |
Latest revision as of 01:29, 23 January 2019
Hemophilia Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Hemophilia echocardiography or ultrasound On the Web |
American Roentgen Ray Society Images of Hemophilia echocardiography or ultrasound |
Risk calculators and risk factors for Hemophilia echocardiography or ultrasound |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1];Associate Editor(s)-in-Chief: Sabawoon Mirwais, M.B.B.S, M.D.[2]
Overview
There are no echocardiography findings associated with hemophilia. Ultrasound may be helpful in the diagnosis and follow-up of hemophilic arthropathy and in diagnosing massive intraabdominal bleeds. Findings on an ultrasound suggestive of hemophilic arthropathy inlcude soft-tissue changes, osteo-chondral changes, joint effusion, synovial hypertrophy, hemosiderin, and osteo-chondral abnormalities.
Echocardiography/Ultrasound
Echocardiography
There are no echocardiography findings associated with hemophilia.
Ultrasound
- Ultrasound may be helpful in the diagnosis and follow-up of hemophilic arthropathy and in diagnosing massive intraabdominal bleeds
- Ultrasound is highly reliable for assessing soft-tissue changes with an intraclass correlation coefficient (ICC) for specific joints given below:
- Ultrasound is substantially to highly reliable for assessing osteo-chondral changes with an intraclass correlation coefficient (ICC) for specific joints given below:
- It is highly sensitive (> 92%) for assessing synovial hypertrophy and hemosiderin in both ankles and knees[1]
- It has borderline sensitivity for detecting small amounts of fluid in ankles (70%) in contrast to knees (93%)
- It has variable sensitivity for evaluating osteo-chondral abnormalities (86-100% for ankles and 12-100% for knees)
References
- ↑ 1.0 1.1 1.2 Doria AS, Keshava SN, Mohanta A, Jarrin J, Blanchette V, Srivastava A, Moineddin R, Kavitha ML, Hilliard P, Poonnoose P, Gibikote S (March 2015). "Diagnostic accuracy of ultrasound for assessment of hemophilic arthropathy: MRI correlation". AJR Am J Roentgenol. 204 (3): W336–47. doi:10.2214/AJR.14.12501. PMID 25714320.