Pulmonary edema interventional therapy: Difference between revisions
Jump to navigation
Jump to search
Created page with "__NOTOC__ {{Pulmonary edema}} {{CMG}} {{AE}} {{FKH}} ==Overview== ==Interventional Therapy== ===Intra-Aortic Balloon Pumping=== ==References== {{reflist|2}} Category:Pu..." |
No edit summary |
||
Line 7: | Line 7: | ||
==Interventional Therapy== | ==Interventional Therapy== | ||
===Intra-Aortic Balloon Pumping=== | ===Intra-Aortic Balloon Pumping=== | ||
* Can be used to achieve hemodynamic stabilization in the patient before definitive therapy | |||
* The intra-aortic balloon pump decreases afterload | |||
* The intra-aortic balloon pump is inserted percutaneously through the femoral artery | |||
* The distal end of the pump is placed distal to the aortic knob and the origin of the left subclavian artery | |||
* For inflation of the balloon helium is used | |||
* Inflation of the balloon should occur in early diastole, just after the aortic valve closes | |||
* Balloon deflation should occur in early systole, just before the aortic valve opens | |||
* Proper inflation leads to an assisted peak diastolic pressure higher than the unassisted peak systolic arterial pressure | |||
* Proper deflation results in assisted aortic end-diastolic pressure of approximately 10mm Hg lower than the unassisted end-diastolic pressure. | |||
==References== | ==References== |
Revision as of 17:03, 8 March 2018
Pulmonary edema Microchapters |
Diagnosis |
---|
Treatment |
Case Studies |
Pulmonary edema interventional therapy On the Web |
Risk calculators and risk factors for Pulmonary edema interventional therapy |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1] Associate Editor(s)-in-Chief: Farnaz Khalighinejad, MD [2]
Overview
Interventional Therapy
Intra-Aortic Balloon Pumping
- Can be used to achieve hemodynamic stabilization in the patient before definitive therapy
- The intra-aortic balloon pump decreases afterload
- The intra-aortic balloon pump is inserted percutaneously through the femoral artery
- The distal end of the pump is placed distal to the aortic knob and the origin of the left subclavian artery
- For inflation of the balloon helium is used
- Inflation of the balloon should occur in early diastole, just after the aortic valve closes
- Balloon deflation should occur in early systole, just before the aortic valve opens
- Proper inflation leads to an assisted peak diastolic pressure higher than the unassisted peak systolic arterial pressure
- Proper deflation results in assisted aortic end-diastolic pressure of approximately 10mm Hg lower than the unassisted end-diastolic pressure.
References