Endocardial cushion defect echocardiography and ultrasound: Difference between revisions
Aditya Ganti (talk | contribs) |
Aditya Ganti (talk | contribs) |
||
Line 10: | Line 10: | ||
==Echocardiography/Ultrasound== | ==Echocardiography/Ultrasound== | ||
Echocardiography | Echocardiography can be helpful in the diagnosis of endocardial cushion defect. Findings on an echocardiography diagnostic of endocardial cushion defect include:<ref name="pmid19083142">{{cite journal |vauthors=Del Pasqua A, Sanders SP, de Zorzi A, Toscano A, Iacobelli R, Pierli C, Pasquini L, Di Donato R, Rinelli G |title=Impact of three-dimensional echocardiography in complex congenital heart defect cases: the surgical view |journal=Pediatr Cardiol |volume=30 |issue=3 |pages=293–300 |date=April 2009 |pmid=19083142 |doi=10.1007/s00246-008-9348-3 |url=}}</ref> | ||
*Diastolic movement of the mitral valve | |||
*Paradoxical motion of the interventricular septum. | |||
*Right ventricular dilatation | |||
*Prolonged diastolic contact between the mitral valve leaflet and the interventricular septum. | |||
*Lack of displacement of the left and right AV valves | |||
<br /> | |||
==References== | ==References== | ||
{{Reflist|2}} | {{Reflist|2}} |
Revision as of 10:14, 25 April 2020
Endocardial cushion defect Microchapters |
Differentiating Endocardial cushion defect from other Diseases |
---|
Diagnosis |
Treatment |
Case Studies |
Endocardial cushion defect echocardiography and ultrasound On the Web |
American Roentgen Ray Society Images of Endocardial cushion defect echocardiography and ultrasound |
FDA on Endocardial cushion defect echocardiography and ultrasound |
CDC on Endocardial cushion defect echocardiography and ultrasound |
Endocardial cushion defect echocardiography and ultrasound in the news |
Blogs on Endocardial cushion defect echocardiography and ultrasound |
Risk calculators and risk factors for Endocardial cushion defect echocardiography and ultrasound |
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Aditya Ganti M.B.B.S. [2]
Overview
Echocardiography can be helpful in the diagnosis of endocardial cushion defect. Findings on an echocardiography diagnostic of endocardial cushion defect include diastolic movement of the mitral valve with paradoxical motion of the interventricular septum. Other findings on echocardiography include absence of the interventricular septum and right ventricular dilatation.
Echocardiography/Ultrasound
Echocardiography can be helpful in the diagnosis of endocardial cushion defect. Findings on an echocardiography diagnostic of endocardial cushion defect include:[1]
- Diastolic movement of the mitral valve
- Paradoxical motion of the interventricular septum.
- Right ventricular dilatation
- Prolonged diastolic contact between the mitral valve leaflet and the interventricular septum.
- Lack of displacement of the left and right AV valves
References
- ↑ Del Pasqua A, Sanders SP, de Zorzi A, Toscano A, Iacobelli R, Pierli C, Pasquini L, Di Donato R, Rinelli G (April 2009). "Impact of three-dimensional echocardiography in complex congenital heart defect cases: the surgical view". Pediatr Cardiol. 30 (3): 293–300. doi:10.1007/s00246-008-9348-3. PMID 19083142.