Upper gastrointestinal bleeding laboratory findings: Difference between revisions
No edit summary |
|||
Line 30: | Line 30: | ||
[[Category:Emergency medicine]] | [[Category:Emergency medicine]] | ||
[[Category:Needs overview]] | [[Category:Needs overview]] | ||
{{WikiDoc Help Menu}} | {{WikiDoc Help Menu}} | ||
{{WikiDoc Sources}} | {{WikiDoc Sources}} |
Revision as of 05:03, 13 February 2013
Upper gastrointestinal bleeding Microchapters |
Differentiating Upper Gastrointestinal Bleeding from other Diseases |
---|
Diagnosis |
Treatment |
Management |
Surgery |
Case Studies |
Upper gastrointestinal bleeding laboratory findings On the Web |
American Roentgen Ray Society Images of Upper gastrointestinal bleeding laboratory findings |
Upper gastrointestinal bleeding laboratory findings in the news |
Blogs on Upper gastrointestinal bleeding laboratory findings |
Directions to Hospitals Treating Upper gastrointestinal bleeding |
Risk calculators and risk factors for Upper gastrointestinal bleeding laboratory findings |
Please help WikiDoc by adding more content here. It's easy! Click here to learn about editing.
Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]
Laboratory Findings
- Laboratory findings include anemia, coagulopathy, and an elevated BUN-to-creatinine ratio.
- Determining whether blood is in gastric contents, either vomited or aspirated specimens, is surprisingly difficult. Slide tests are based on orthotolidine (Hematest reagent tablets and Bili-Labstix) or guaiac (Hemoccult and Gastroccult). Rosenthal found orthotolidine-based tests more sensitive than specific; the Hemoccult test's sensitivity reduced by the acidic environment; and the Gastroccult test be the most accurate[2]. Cuellar found the following results:
Finding | Sensitivity | Specificity | Positive predictive value (prevalence of 39%) |
Negative predictive value (prevalence of 39%) |
---|---|---|---|---|
Gastroccult | 95% | 82% | 77% | 96% |
Physician assessment | 79% | 55% | 53% | 20% |
Holman used simulated gastric specimens and found the Hemoccult test to have significant problems with non-specificy and false-positive results, whereas the Gastroccult test was very accurate[4]. Holman found that by 120 seconds after the developer was applied, the Hemoccult test was positive on all control samples.