==Overview==
==Overview==
 
Methemoglobinemia can be diagnosed with several laboratory findings.
'''Congenital (Hereditary) Methemoglobinemia'''
 
There are three main congenital conditions that lead to [[methemoglobinemia]]:
 
1. [[Cytochrome b5 reductase deficiency]] and [[pyruvate kinase deficiency]]
 
2. [[G6PD deficiency]]
 
3. Presence of abnormal [[hemoglobin]].
 
 
'''Acquired or Acute Methemoglobinemia'''
 
Most common cause include different [[oxidant drugs]], [[toxins]] or [[chemicals]]


==Laboratory Findings==       
==Laboratory Findings==       
<ref>{{ Rev Bras Anestesiol. 2008 Nov-Dec;58(6):651-64. Methemoglobinemia: from diagnosis to treatment. [Article in English, Portuguese] do Nascimento TS1, Pereira RO, de Mello HL, Costa J.pmid=PMID: 19082413}}</ref>  <ref>{{ Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:4570-4573. doi: 10.1109/EMBC.2017.8037873.
       
Three-wavelength method for the optical differentiation of methemoglobin and sulfhemoglobin in oxygenated blood.
Van Leeuwen SR, Baranoski GVG, Kimmel BW. pmid=29060914 }}</ref>      <ref>{{Toxicol Rev. 2003;22(1):13-27.
Occupational methaemoglobinaemia. Mechanisms of production, features, diagnosis and management including the use of methylene blue.
Bradberry SM1. pmid=14579544}}</ref>    <ref>{{South Med J. 2011 Nov;104(11):757-61. doi: 10.1097/SMJ.0b013e318232139f.
Methemoglobinemia: pathogenesis, diagnosis, and management.
Skold A1, Cosco DL, Klein R. pmid=22024786 }}</ref>
 
 
'''ABG Analysis'''
'''ABG Analysis'''


On routine [[ABG analysis]] the [[partial pressure]] of [[oxygen]] ([[PO2]]) value should in normal reference ranges in patients with [[methemoglobinemia]]. The reason lies in the fact that the [[ABG]] value represents the [[oxygen]] content in the [[plasma]], and not the oxygen-carrying capacity of [[hemoglobin]].
*On routine [[ABG analysis]] the [[partial pressure]] of [[oxygen]] ([[PO2]]) value should in normal reference ranges in patients with [[methemoglobinemia]]. The reason lies in the fact that the [[ABG]] value represents the [[oxygen]] content in the [[plasma]], and not the [[oxygen-carrying capacity of hemoglobin]].<ref>{{ Rev Bras Anestesiol. 2008 Nov-Dec;58(6):651-64. Methemoglobinemia: from diagnosis to treatment. [Article in English, Portuguese] do Nascimento TS1, Pereira RO, de Mello HL, Costa J.pmid=PMID: 19082413}}</ref> <ref>{{South Med J. 2011 Nov;104(11):757-61. doi: 10.1097/SMJ.0b013e318232139f.
Methemoglobinemia: pathogenesis, diagnosis, and management.
Skold A1, Cosco DL, Klein R. pmid=22024786 }}</ref> <ref>{{Toxicol Rev. 2003;22(1):13-27.
Occupational methaemoglobinaemia. Mechanisms of production, features, diagnosis and management including the use of methylene blue.
Bradberry SM1. pmid=14579544}}</ref> 


'''Co-oximetry'''
'''Co-oximetry'''


The [[co-oximeter]] is the most accurate device to measure [[methemoglobin]]. The newer generation devices can actually differentiate between [[methemoglobin]], [[carboxyhemoglobin]], [[oxyhemoglobin]], [[deoxyhemoglobin]], and also  
*The [[co-oximeter]] is the most accurate device to measure [[methemoglobin]]. The newer generation devices can actually differentiate between [[methemoglobin]], [[carboxyhemoglobin]], [[oxyhemoglobin]], [[deoxyhemoglobin]], and also [[sulfhemoglobin]].<ref>{{ Anesth Analg. 2010 Jul;111(1):143-8. doi: 10.1213/ANE.0b013e3181c91bb6. Epub 2009 Dec 10.
[[sulfhemoglobin]].
Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
 
Feiner JR1, Bickler PE, Mannheimer PD. pmid=20007731}}</ref> 
 
'''Pulse oximetry'''
'''Pulse oximetry'''


The [[pulse oximetry]] in [[methemoglobinemia]] patients will always show a value around  85%, regardless of the level of [[MetHb]] in the blood. This is very importan tot know as this value can be misleading especially in patients with very high [[MetHb]] levels
*The [[pulse oximetry]] in [[methemoglobinemia]] patients will always show a value around  85%, regardless of the level of [[MetHb]] in the blood. This is very importan tot know as this value can be misleading especially in patients with very high [[MetHb]] levels. Fortunately new [[multiwavelength pulse oximeters]] have been developed recently and they can detect the levels of [[MetHb]] more accurately. <ref>{{ Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:4570-4573. doi: 10.1109/EMBC.2017.8037873. Three-wavelength method for the optical differentiation of methemoglobin and sulfhemoglobin in oxygenated blood.
Fortunately new multiwavelength [[pulse oximeters]] have been developed recently and they can detect the levels of [[MetHb]] more accurately.  
Van Leeuwen SR, Baranoski GVG, Kimmel BW. pmid=29060914 }}</ref>


In [[methemoglobinemia]] patients we often see the so called “[[saturation gap]]” which can help us diagnose the condition. The gap is calculated by subtracting the [[oxygen]] percentage from the [[ABG analysis]] (typically normal in [[methemoglobinemia]] patients 100%) from the percentage of [[oxygen saturation]] given by the [[pulse oximeter]] (always ~85% in [[methemoglobiemia]] patients). [[Saturaion gap]] more than 5 % is significant.
*In [[methemoglobinemia]] patients we often see the so called “[[saturation gap]]” which can help us diagnose the condition. The gap is calculated by subtracting the [[oxygen]] percentage from the [[ABG analysis]] (typically normal in [[methemoglobinemia]] patients 100%) from the percentage of [[oxygen saturation]] given by the [[pulse oximeter]] (always ~85% in [[methemoglobiemia]] patients). [[Saturaion gap]] more than 5% is significant.


{{Reflist|2}}


==References==
==References==

Revision as of 14:41, 15 May 2018

Methemoglobinemia Microchapters

Home

Patient Information

Overview

Historical Perspective

Classification

Pathophysiology

Causes

Differentiating Methemoglobinemia from other Diseases

Epidemiology and Demographics

Risk Factors

Screening

Natural History, Complications and Prognosis

Diagnosis

Diagnostic Study of Choice

History and Symptoms

Physical Examination

Laboratory Findings

Chest X Ray

CT

MRI

Ultrasound

Other Imaging Findings

Other Diagnostic Studies

Treatment

Medical Therapy

Surgery

Primary Prevention

Secondary Prevention

Cost-Effectiveness of Therapy

Future or Investigational Therapies

Case Studies

Case #1

Methemoglobinemia laboratory findings On the Web

Most recent articles

Most cited articles

Review articles

CME Programs

Powerpoint slides

Images

American Roentgen Ray Society Images of Methemoglobinemia laboratory findings

All Images
X-rays
Echo & Ultrasound
CT Images
MRI

Ongoing Trials at Clinical Trials.gov

US National Guidelines Clearinghouse

NICE Guidance

FDA on Methemoglobinemia laboratory findings

on Methemoglobinemia laboratory findings

Methemoglobinemia laboratory findings in the news

Blogs on Methemoglobinemia laboratory findings

Directions to Hospitals Treating Methemoglobinemia

Risk calculators and risk factors for Methemoglobinemia laboratory findings

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Associate Editor(s)-in-Chief: Template:Aksiniya K. Stevasarova, M.D.

Overview

Methemoglobinemia can be diagnosed with several laboratory findings.

Laboratory Findings

ABG Analysis

Co-oximetry

Pulse oximetry


References

  1. {{ Rev Bras Anestesiol. 2008 Nov-Dec;58(6):651-64. Methemoglobinemia: from diagnosis to treatment. [Article in English, Portuguese] do Nascimento TS1, Pereira RO, de Mello HL, Costa J.pmid=PMID: 19082413}}
  2. {{South Med J. 2011 Nov;104(11):757-61. doi: 10.1097/SMJ.0b013e318232139f. Methemoglobinemia: pathogenesis, diagnosis, and management. Skold A1, Cosco DL, Klein R. pmid=22024786 }}
  3. {{Toxicol Rev. 2003;22(1):13-27. Occupational methaemoglobinaemia. Mechanisms of production, features, diagnosis and management including the use of methylene blue. Bradberry SM1. pmid=14579544}}
  4. {{ Anesth Analg. 2010 Jul;111(1):143-8. doi: 10.1213/ANE.0b013e3181c91bb6. Epub 2009 Dec 10. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. Feiner JR1, Bickler PE, Mannheimer PD. pmid=20007731}}
  5. {{ Conf Proc IEEE Eng Med Biol Soc. 2017 Jul;2017:4570-4573. doi: 10.1109/EMBC.2017.8037873. Three-wavelength method for the optical differentiation of methemoglobin and sulfhemoglobin in oxygenated blood. Van Leeuwen SR, Baranoski GVG, Kimmel BW. pmid=29060914 }}

Template:WS Template:WH