P wave

Revision as of 02:01, 30 October 2012 by Rim Halaby (talk | contribs)
Jump to navigation Jump to search
Schematic representation of normal ECG

WikiDoc Resources for P wave

Articles

Most recent articles on P wave

Most cited articles on P wave

Review articles on P wave

Articles on P wave in N Eng J Med, Lancet, BMJ

Media

Powerpoint slides on P wave

Images of P wave

Photos of P wave

Podcasts & MP3s on P wave

Videos on P wave

Evidence Based Medicine

Cochrane Collaboration on P wave

Bandolier on P wave

TRIP on P wave

Clinical Trials

Ongoing Trials on P wave at Clinical Trials.gov

Trial results on P wave

Clinical Trials on P wave at Google

Guidelines / Policies / Govt

US National Guidelines Clearinghouse on P wave

NICE Guidance on P wave

NHS PRODIGY Guidance

FDA on P wave

CDC on P wave

Books

Books on P wave

News

P wave in the news

Be alerted to news on P wave

News trends on P wave

Commentary

Blogs on P wave

Definitions

Definitions of P wave

Patient Resources / Community

Patient resources on P wave

Discussion groups on P wave

Patient Handouts on P wave

Directions to Hospitals Treating P wave

Risk calculators and risk factors for P wave

Healthcare Provider Resources

Symptoms of P wave

Causes & Risk Factors for P wave

Diagnostic studies for P wave

Treatment of P wave

Continuing Medical Education (CME)

CME Programs on P wave

International

P wave en Espanol

P wave en Francais

Business

P wave in the Marketplace

Patents on P wave

Experimental / Informatics

List of terms related to P wave

Editor-In-Chief: C. Michael Gibson, M.S., M.D. [1]; Assistant Editor(s)-in-Chief: Rim Halaby

Overview

During normal atrial depolarization, the main electrical vector is directed from the SA node towards the AV node, and spreads from the right atrium to the left atrium. This turns into the P wave on the ECG, which is upright in II, III, and aVF (since the general electrical activity is going toward the positive electrode in those leads), and inverted in aVR (since it is going away from the positive electrode for that lead).

The P wave Morphology

The P wave represents atrial depolarization (stimulation). At either slow or normal heart rates, the small, rounded P wave is clearly visible just before the taller, more peaked QRS complex. At more rapid rates, however, the P wave may merge with the preceding T wave and become difficult to identify. Sinus node depolarization is too small in amplitude to be recorded from the body surface so it is not seen.

P waves have four steps to be identified;

1. Examination of the P wave contour. The P wave contour is normally smooth, and is either entirely positive or entirely negative wave (monophasic wave) in all leads except V1.

2. Measurement of the P wave duration. The P wave duration is normally less than 0.12 seconds.

3. Measurement of the maximal P wave amplitude. The maximal P-wave amplitude is normally no more than 0.2 mV in the frontal plane leads and no more than 0.1 mV in the transverse plane leads.

4. Estimation of the P wave axis. The P wave normally appears entirely upright on leftward and inferiorly oriented leads such as I, II, aVF, and V4 to V6. It is negative in aVR because of the rightward orientation of that lead, and it is variable in the other standard leads. The normal limits of the P wave axis are 0 degrees and +75 degrees.

Characteristics of a normal p wave:Spodick
  • The maximal height of the P wave is 2.5 mm in leads II and/or III
  • The P wave is positive in II and aVF, and biphasic in V1
  • The P wave duration is usually shorter than 0.12 seconds
Shown below is an electrocardiogram depicting a normal sinus rhythm with a positive p wave in leads I, II and aVF and a biphasic P wave in V1.

Normal sinus rhythm with a positive p wave in leads I, II and aVF and a biphasic P wave in V1.

The P Wave in Normal Sinus Rhythm

A P wave must be upright in leads II and aVF and inverted in lead aVR to designate a cardiac rhythm as normal sinus rhythm. The relationship between P waves and QRS complexes helps distinguish various cardiac arrhythmias. If the P wave is inverted, then the origin of the rhythm may be in the low atrial region.

Widened P waves can be a sign of Class Ia antiarrhythmic drugs intoxication (quinidine, etc.) and small or absent P waves can be a sign of hyperkalemia.

Abnormal P Wave Examples

Elevation or depression of the PTa segment (the part between the p wave and the beginning of the QRS complex) can result from atrial infarction or pericarditis.


Altered P wave morphology is seen in left or right atrial enlargement. If the p-wave is enlarged, the atria are enlarged.

The P Wave in Left Atrial Enlargement

The shape and duration of the P waves may indicate atrial enlargement. Left atrial enlargement may be observed among patients with mitral insufficiency.

Criteria for left atrial enlargement. Either
P wave with a broad (>0.04 sec or 1 small square) and deeply negative (>1 mm) terminal part in V1 (P mitrale)
P wave duration >0.12 sec in leads I and / or II

Differential Diagnosis of Left Atrial Enlargement

The P Wave in Right Atrial Enlargement

Right atrial enlargement can result from increased right-sided pressures such as those related to valvular lesions and after pulmonary embolism. A positive part of the biphasic P wave in lead V1 larger than the negative part indicates right atrial enlargement. The width of the P wave is not part of the criteria for right atrial enlargement.

Right atrial enlargement is defined as either
P is taller than 2.5 mm in II / III and / or aVF (P pulmonale)
P >1.5 mm in V1

Differential Diagnosis of Right Atrial Enlargement

Differential Diagnosis of Inverted P Waves in I and aVL

It is possible to distinguish lead reversal and dextrocardia by watching the precordial leads. Dextrocardia will show an R wave inversion, whereas lead reversal will not.

This bottom EKG shows marked right axis deviation and loss of voltage across the precordium. There are also inverted P waves in leads I and aVL. The differential for inverted P waves in lead I and aVL is Dextrocardia vs Reversed Arm Leads. Since there is loss of voltage across the precordium this is Dextrocardia.

If the P waves are inverted in the other leads, then this may indicate that there is a low atrial focus to the origin of the rhythm.

Inverted P Wave in the Inferior Leads

Causes

P waves are inverted in the inferior leads in the setting of a low atrial focus as the origin of the rhythm.

Sources

References


Template:WikiDoc Sources